Need a manual for your Aube TH232-AF-230 Thermostat? Below you can view and download the PDF manual for free in English. This product currently has 2 frequently asked questions, 18 comments and has 9 votes with an average product rating of 78/100. If this is not the manual you want, please contact us.

Is your product defective and the manual offers no solution? Go to a Repair Café for free repair services.

Manual

Loading…

TH232-AF-230 400-232-003-B 2010-05-26 1/4
One (1) thermostat
One (1) floor sensor
One (1) wall plate
Turn off power to the heating system at the main power panel to
avoid electrical shock. Installation should be carried out by an
electrician.
All work must conform to the applicable country standards for
electrical installations and wiring.
This thermostat should be connected on a circuit equipped with
a fuse or a circuit breaker. It must be installed on a certified
electrical box equipped with non-metallic cable strain relief
adapters. Use separate adapters for the high-voltage wires and
for the sensor cable.
For a new installation, choose a location about 1.5 m above the
floor.
For electric baseboards, convectors and fan-forced heaters, the
thermostat must be installed facing the heating system and on
an inside wall.
Avoid locations where there are air drafts (top of staircase, air
outlet), dead air spots (behind a door), direct sunlight or
concealed chimneys or stove pipes.
NOTE: The terminals are designed to handle a cross-section of wire
measuring 0.33 to 3.1 mm
2
.
Loosen the captive screw underneath the base and remove the
faceplate from the base.
Before making the connections, make sure
that the base covers the electrical box
entirely. If not, install a wall plate at the
back of the base.
Connect the wires:
Power:
Terminals 1 & 5
Load:
Terminals 2 & 4
see note 1
Pilot Wire:
Terminal 3
see note 2
Floor sensor:
Terminals 6 & 7
(no polarity)
see note 3
WARNING: Ensure that the wires are tightly secured to the terminals.
Apply a minimum torque of 0.5 Nm (4.4 Lb/in) when tightening the
screws.
Note 1 If a contactor is used between the thermostat and the load,
install a snubber at the contactor’s coil terminal to ensure
the proper operation of the thermostat.
Note 2 This connection is required on some models only.
Note 3 The sensor cable must pass outside the electrical box and
travel inside the wall to the floor. For the proper operation of
the thermostat, the floor sensor must be centered between
two heater wires having a maximum temperature of 80 °C
(176 °F). The floor sensor wire must not cross any heater
wire or be placed close to it.
Push wires into the electrical box and
secure the base to the electrical box
anchorage. The head of the screw
must be less than 2 mm thick.
Return the faceplate
to the base.
Return power to the heating system.
NOTE: Keep the thermostat's air vents clean and unobstructed at all
times.
Parts
1.
Guidelines
2.
Procedure
3.
Base
Faceplate
TH232-AF-230
Installation Instructions
230 V Base
400-232-003-B (Aube TH232-AF-230-OEM) ENG.fm Page 1 Wednesday, May 26, 2010 1:51 PM
Download manual in English (PDF, 0.95 MB)
(Consider the environment and only print this manual if it is really necessary)

Loading…

Rating

Let us know what you think about the Aube TH232-AF-230 Thermostat by leaving a product rating. Want to share your experiences with this product or ask a question? Please leave a comment at the bottom of the page.
Are you satisfied with the Aube TH232-AF-230 Thermostat?
Yes No
78%
22%
9 votes

Join the conversation about this product

Here you can share what you think about the Aube TH232-AF-230 Thermostat. If you have a question, first carefully read the manual. Requesting a manual can be done by using our contact form.

David Holmes 21-10-2019
I have recently replaced the thermostat control panel due to the breakdown of the previous one. Having fitted it I can get the floor to heat o.k. on manual setting but I have an error message saying LO. This would suggest I have a problem with the sensor but there is no way to access it as it is under tiles which are cemented in. Is there anything I can do to get the automatic controls to operate?

reply | This was helpful (35)
John Scott 06-01-2021
My unit appears to power off occasionally, showing just a blank screen. Switching the power off and on resets the unit for a few days and it functions correctly, Then it happens again. But why? The floor heating elements appear to be good, and the unit functions for a few days. What external fault would cause the unit to go into 'blank screen' state?

reply | This was helpful (29) Read more
Becky 24-10-2023
Hi, I have the same problem with a totally blank screen, how did you fix it? How did you turn it on and off as a temporary fix as the power button on the thermostat is unresponsive?

This was helpful (0)
Chris Zoetmulder 14-06-2019
The screen is totally blank

reply | This was helpful (19) Read more
Becky 24-10-2023
Hi, I have the same problem, how did you fix it?

This was helpful (0)
Maya 25-07-2019
Hello my termistat show 36c and don’t stop wat I have to dou?

reply | This was helpful (14)
Karen 07-12-2019
Underfloor heating is not working. Can you help?

reply | This was helpful (11)

Loading…

Paul Burrowbridge 06-05-2021
My control panel has suddenly started displaying an abnormally high floor temperature figure - around 34 degrees C. It's usually set for 28 degrees C While the 34 is showing, no floor heating takes place. No matter to what figure I change the display, the 34 always returns. If I raise the 34 manually to something like 38, then the floor heats up. It looks as if the floor temperature figure has to be set about 6 or more degrees higher than the displayed temperature to get the heating to work.

reply | This was helpful (9) Read more
John Wilkinson 17-11-2023
Did you get an answer for this as I am having the exact same issue where the resting floor temperature being displayed is around 30 degrees C when no heating has been on within several days.

This was helpful (0)
Lucy Bishop 28-11-2021
My underfoot heating has stopped coming on. The control panel is working and when the heating should come on you can here it click the screen then flashes blank before returning to normal.But no heat

reply | This was helpful (8)
Saskia Warmerdam 22-08-2019
The display shows nothing, even though there is voltage on it. What could this be?

reply | This was helpful (7) (Translated by Google)
Lynne Carroll 11-10-2021
There is no display on the thermostat so we have no underfloor heating. The fuse has been replaced in the power panel..do you have any suggestions for what the fault might be?

reply | This was helpful (4) Read more
Becky 24-10-2023
Hi, I have the same problem, how did you fix it?

This was helpful (0)
Marcy 17-03-2022
I have fiddled with the settings & now want to go Back to the pre programmed schedule but can’t find how to. Any help would be appreciated

reply | This was helpful (4)
Tony Atallah 01-01-2023
My TH232 thermostat shows that it is heating ok, but actually it doesn't. Could there be anything wrong with the underfloor resistance? It is tiled over it so very difficult to access

reply | This was helpful (3)
Lorraine Grant 17-03-2023
How do I know my heating is off

reply | This was helpful (0)
Becky 24-10-2023
My thermostat screen is completely blank - I’ve seen other people had a similar problem, how did you fix it? Thanks

reply | This was helpful (0)
Sarah 07-12-2023
My unit is flashing between numbers which I think are the programmed temperatures and the full number screen you get at turn on. The heating isn't working. If I turn it off for a bit then on again it looks normal for maybe 15mins then reverts to the flashing and floor never heats up. Any ideas? It isn't any of the error codes shown in manuals that I can find.

reply | This was helpful (0)

More about this manual

We understand that it’s nice to have a paper manual for your Aube TH232-AF-230 Thermostat. You can always download the manual from our website and print it yourself. If you would like to have an original manual, we recommend you contact Aube. They might be able to provide an original manual. Are you looking for the manual of your Aube TH232-AF-230 Thermostat in a different language? Choose your preferred language on our homepage and search for the model number to see if we have it available.

Specifications

Brand Aube
Model TH232-AF-230
Category Thermostats
File type PDF
File size 0.95 MB

All manuals for Aube Thermostats
More manuals of Thermostats

Frequently Asked Questions about Aube TH232-AF-230 Thermostat

Our support team searches for useful product information and answers to frequently asked questions. If you find an inaccuracy in our frequently asked questions, please let us know by using our contact form.

What is the dead zone of a thermostat? Verified

Many modern thermostats have a dead zone. If the temperature deviates less than 4°C from the set temperature, the system will not heat or cool. This so called dead zone of the thermostat prevents the system from turning on and off too often, saving energy.

This was helpful (1588) Read more

What is the best place to mount a thermostat? Verified

The best place for a thermostat is approximately 1,5 meter above the ground. Never place the thermostat nead a radiator or other heat emitting equipment or in direct sunlight. Choose a room that is used often. In most cases this is the living room.