Manual Aube TH132 F Thermostat

Need a manual for your Aube TH132 F Thermostat? Below you can view and download the PDF manual for free in English. This product currently has 2 frequently asked questions, 6 comments and has 6 votes with an average product rating of 17/100. If this is not the manual you want, please contact us.

Is your product defective and the manual offers no solution? Go to a Repair Café for free repair services.

Manual

Loading…

Thank you for choosing the Aube TH132, a programma-
ble thermostat that provides both energy savings and total
comfort.
n DAY/HOUR/MIN—Set the day and clock settings.
o PGM—Program the schedule (programs).
p MODE—Select the operating mode.
RETURN—To exit a function.
q To configure temperature setpoints:
Comfort, Economy and Vacation.
r Adjust the floor temperature limit (AF only).
s —Increase and decrease temperature.
t —Indicates the number of the current
program when Automatic mode is enabled.
u Current operating mode (auto / manual ). In
Auto mode, the program’s associated setpoint icon is
also displayed ( ).
v Indicates the room OR floor temperature.
w Heating indicators (see “Temperature Control”
below).
TH132-A
This model has been designed to control a room’s ambi-
ent temperature.
The TH132-A has one temperature sensor located in the
control module.
TH132-AF
This model is designed to use a floor sensor to control the
room temperature.
The TH132-AF has two temperature sensors:
The first one, installed in the control module, controls
the ambient temperature.
The second one, installed in the floor (and connected
to the power base), limits the temperature of the floor
(the default setting of this limit is 82°F).
TH132-F
This model is designed to control floor heating systems.
The TH132-F has one temperature sensor installed in the
floor (sensor is connected to the power base).
The TH132 has two switches, located on the upper-left
part on the rear of the control module, which are used to
set the following options:
Early Start
When the Early Start function is enabled (disabled by
default), the TH132 calculates the optimum system start
time to obtain the desired temperature by the set time. To
enable this function:
Position switch #1 down.
Note: When this function is enabled, the
system can be activated before the pro-
gram’s start time.
Temperature Display
By default, the TH132 displays the temperature in °C. If
you wish to change to °F:
Position switch #2 up.
Note: When you switch from °C to °F or vice
versa, the , and setpoints must be
redefined.
Control Module
TH132 A/F/AF
Owner’s Guide
TH132 Description
Models Overview
Configure the Switches
Align the bracket tabs on the control module with the
holes located on top of the power base.
This control module must be installed on a PB130 series
power base.
Note: Keep the thermostat's air vents clean and free from
obstructions.
Note: The screw cannot be removed completely.
On the first installation, the screen displays:
0:00, MO, and temperature (room/floor).
For Floor Heating Installations:
One of the two following messages may be dis-
played when a problem occurs:
LO: The floor temperature is below 32°F (0°C), or
the temperature sensor is defective, or not
connected.
The heating indicator is displayed and
the relay is closed (energized).
HI: The floor temperature is above
140°F (60°C), or the temperature sensor is
defective.
n Set the time (HOUR - MIN).
o Set the day (DAY).
If you remove the module from its base for more than
2 hours, the time and day will have to be reprogrammed.
Comfort and Economy Setpoints
These setpoints are associated with the schedule’s pro-
grams (prog. 1 & 3 = Comfort, prog. 2 & 4 = Economy)
and are preprogrammed as follows:
A & AF models— 68°F, 64°F
F model— 82°F, 68°F
To modify a setpoint:
n Set the temperature using and press and hold the
or button until it is displayed on the screen.
o Press MODE/RETURN to exit.
Vacation Setpoint
The vacation setpoint is associated to the Vacation oper-
ating mode and is preprogrammed to 50°F. To modify this
setpoint, repeat above steps.
Floor Temperature Setpoint (AF model only)
The floor temperature limit is preprogrammed to 82°F to
avoid damage to your floor.
To modify, press the adjustment button (below ) using a
pointed object, set the desired temperature using and
press MODE/RETURN to exit.
The TH132 offers three operating modes:
Automatic Executes the schedule.
n Press MODE to select . The current
program number is displayed.
You can temporarily bypass the current
program by setting a specific temperature setpoint
or by selecting one of the pre-defined setpoint
buttons ( ). The new setpoint will be maintained
until the beginning of the next program.
Manual —Maintains a constant temperature.
n Press MODE to select .
o Set temperature or select one of the pre-
defined setpoint buttons ( ).
Vacation —Maintains the Vacation setpoint
during a prolonged absence.
Press .
Install the Control Module
Power base
Control module
Air vents
Air vents
First Power ON
Set the Time and Day
Adjust the Temperature Setpoints
Select the Operating Mode
400-132-000-A
Download manual in English (PDF, 0.37 MB)
(Consider the environment and only print this manual if it is really necessary)

Loading…

Rating

Let us know what you think about the Aube TH132 F Thermostat by leaving a product rating. Want to share your experiences with this product or ask a question? Please leave a comment at the bottom of the page.
Are you satisfied with the Aube TH132 F Thermostat?
Yes No
17%
83%
6 votes

Join the conversation about this product

Here you can share what you think about the Aube TH132 F Thermostat. If you have a question, first carefully read the manual. Requesting a manual can be done by using our contact form.

Karin 11-01-2022
I have a question about the Th132f thermostat. He checks the temperature at the audible 'click', then thinks 'I have to turn on' and shows that with the dashes below, and then goes off completely (entire display) ... And a few seconds later the time and temperature appear again to go through the above cycle over and over again. However, the underfloor heating no longer comes on. Not even with a difference of less than 4 degrees (dead zone). Do you have an idea where our problem could be?

reply | This was helpful (2) (Translated by Google)
liam mccartney 29-04-2021
Can you tell me the NTC rating is please?

reply | This was helpful (0)
Marina 27-08-2021
How can I change Fahrenheit to Celsius?

reply | This was helpful (0) Read more (Translated by Google)
Gerard 09-01-2023
Just read this message. Bit late, but on the back of your thermostat you can convert the switch from F to C.

This was helpful (0) (Translated by Google)
Willy verwimp 03-09-2023
My heating does not follow the thermostat program, always continues to provide heat.

reply | This was helpful (0) (Translated by Google)
Eliott Tardieu 02-12-2023
Hi, my thermonet TH132-F doesn’t heat up the floor. I have set the temperature to 82F, manual mode but nothing happens. On the screen I can see the following icons: Hand- sun- 59F (which doesn’t moves up) and the 5 crescendo bars at the bottom left. Would you have any solution please? Thank you very much. Eliott

reply | This was helpful (0)

More about this manual

We understand that it’s nice to have a paper manual for your Aube TH132 F Thermostat. You can always download the manual from our website and print it yourself. If you would like to have an original manual, we recommend you contact Aube. They might be able to provide an original manual. Are you looking for the manual of your Aube TH132 F Thermostat in a different language? Choose your preferred language on our homepage and search for the model number to see if we have it available.

Specifications

Brand Aube
Model TH132 F
Category Thermostats
File type PDF
File size 0.37 MB

All manuals for Aube Thermostats
More manuals of Thermostats

Frequently Asked Questions about Aube TH132 F Thermostat

Our support team searches for useful product information and answers to frequently asked questions. If you find an inaccuracy in our frequently asked questions, please let us know by using our contact form.

What is the dead zone of a thermostat? Verified

Many modern thermostats have a dead zone. If the temperature deviates less than 4°C from the set temperature, the system will not heat or cool. This so called dead zone of the thermostat prevents the system from turning on and off too often, saving energy.

This was helpful (1588) Read more

What is the best place to mount a thermostat? Verified

The best place for a thermostat is approximately 1,5 meter above the ground. Never place the thermostat nead a radiator or other heat emitting equipment or in direct sunlight. Choose a room that is used often. In most cases this is the living room.

This was helpful (990) Read more
Manual Aube TH132 F Thermostat

Related products

Related categories