TH115 A/F/AF 400-115-003-B 27/2/07 2/2
6.3 Floor Temperature Limits (AF mode only)
NOTE: To avoid damaging your floor, follow your floor supplier’s recom-
mendations regarding floor temperature limits.
The minimum and maximum floor temperature limits are 5 °C (41 °F) and
28 °C (82 °F) by default. To modify these limits, proceed as follows:
n Switch the thermostat to Standby.
o Press and hold the button.
p Switch the thermostat back to On.
q Release the button when the minimum temperature
limit (FL:LO) appears.
r Set the minimum temperature limit using the buttons.
s Press the button to display the maximum temperature
limit (FL:HI).
t Set the maximum temperature limit using the buttons.
u Press Mode/Ret to exit.
The thermostat has 3 modes of operation.
7.1 Automatic Mode
The thermostat follows the programmed schedule. To place the ther-
mostat in this mode, press Mode/Ret until is displayed. The data of
the current schedule period are also displayed.
Temporary Bypass
If you modify the setpoint temperature (by pressing the , or
button) when the thermostat is in automatic mode, the new tempera-
ture will be used until the beginning of the next period. flashes dur-
ing the bypass. You can cancel the bypass by pressing Mode/Ret.
Programmed Schedule
The schedule consists of 4 periods per day which represents a typi-
cal week day. You can program the thermostat to skip the periods
that do not apply to your situation. For example, you can skip periods
2 and 3 for the weekend.
The Comfort ( ) temperature is used in periods 1 and 3 and the
Economy ( ) temperature is used in periods 2 and 4. For example,
when the period changes from 1 to 2, the setpoint automatically
changes from Comfort ( ) temperature to Economy ( ) temperature.
You can have a different program for each day of the week; i.e., each
period can start at different time for each day of the week. The
thermostat has been programmed with the following schedule.
To modify the schedule:
n Press Pgm to access the programming mode. Period 1 is
selected.
o Press Day to select the day to program (hold for 3 seconds to
select the entire week).
p Press Hour and Min to set the start time of the selected period,
or press Clear if you want to skip the period (--:-- is displayed).
NOTE: If you intend to use only 2 periods, set periods “1 and 4”
or periods “2 and 3”. Early Start will not work if you set periods
“1 and 2” or periods “3 and 4” .
q Press Pgm to select another period, or press Day to select
another day. Then repeat step 3.
r Press Mode/Ret to exit the programming mode.
NOTE: If no button is pressed for 60 seconds, the thermostat will
automatically exit the programming mode.
7.2 Manual Mode
The programmed schedule is not used. The temperature must be set
manually. To place the thermostat in this mode:
n Press Mode/Ret until is displayed.
o Set the temperature using the , or button.
7.3 Vacation Mode
In this mode, the thermostat is set to Vacation temperature. There
are two ways to place the thermostat in Vacation mode:
By pressing the button on the thermostat. When the Vacation
mode is activated using the button, the icon appears on the
screen without flashing.
From an Aube telephone controller (CT240/CT241) or any other
remote control device equipped with a dry contact if your power
base is equipped with the ECONO input. When the contact
closes, the Vacation mode is activated and the icon flashes on
the screen. All buttons on the thermostat are locked. When the
contact opens, the thermostat returns to the preceding mode.
NOTE: When the Vacation mode is activated using a remote
control device, it can only be deactivated using the device.
The measured temperature is below the thermostat’s display
range. Heating is activated.
The measured temperature is above the thermostat’s display
range. Heating is deactivated.
Verify the thermostat and sensor connections.
:
Power supply: Refer to the power base’s installation guide.
Display range: 0 °C to 70 °C (32 °F to 158 °F)
Ambient setpoint range (A/AF modes)
: 5 °C to 30 °C (40 °F - 86 °F)
Floor setpoint range (F mode): 5 °C to 40 °C (40 °F - 104 °F)
Floor limit range (AF mode): 5 °C to 40 °C (40 °F - 104 °F)
Display resolution: 0.5 °C (1 °F)
Operating temperature: 0 °C to 50 °C (32 °F to 120 °F)
Storage temperature: -20 °C to 50 °C (-4 °F to 120 °F)
Heating cycle length: Refer to the power base’s installation guide
Data backup: In the event of a power failure, most settings are saved.
Only the time must be re-adjusted if the power failure lasts more than 6
hours. The thermostat will return to the mode that was active prior to the
power failure.
Aube warrants this product, excluding battery, to be free from defects in the work-
manship or materials, under normal use and service, for a period of three (3) years
from the date of purchase by the consumer. If at any time during the warranty
period the product is determined to be defective or malfunctions, Aube shall repair
or replace it (at Aube's option).
If the product is defective,
(i) return it, with a bill of sale or other dated proof of purchase, to the place from
which you purchased it, or
(ii) contact Aube. Aube will make the determination whether the product should
be returned, or whether a replacement product can be sent to you.
This warranty does not cover removal or reinstallation costs. This warranty shall
not apply if it is shown by Aube that the defect or malfunction was caused by dam-
age which occurred while the product was in the possession of a consumer.
Aube's sole responsibility shall be to repair or replace the product within the terms
stated above. AUBE SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF
ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES
RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WAR-
RANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PROD-
UCT. Some provinces, states or regions do not allow the exclusion or limitation of
incidental or consequential damages, so this limitation may not apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY AUBE MAKES ON THIS
PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE, IS HEREBY LIMITED TO THE THREE-YEAR DURATION OF THIS
WARRANTY. Some provinces, states or regions do not allow limitations on how
long an implied warranty lasts, so the above limitation may not apply to you.
This warranty gives you specific legal rights, and you may have other rights which
vary from province, state or region to another.
For any questions regarding product installation or operation, contact us
at:
705 Montrichard
Saint-Jean-sur-Richelieu, Quebec
J2X 5K8
Canada
Tel.: (450) 358-4600
Toll-free: 1-800-831-AUBE
Fax: (450) 358-4650
E-mail: aube.servic[email protected]
For more information on our products, visit us at:
www.aubetech.com
t
Modes of Operation
7.
Period Description Associated temperature setting
Wake-up
Away from home
Return home
Sleep
Period Setting
MO TU WE TH FR SA SU
6:00 6:00 6:00 6:00 6:00 6:00 6:00
8:30 8:30 8:30 8:30 8:30 --:-- --:--
17:00 17:00 17:00 17:00 17:00 --:-- --:--
23:00 23:00 23:00 23:00 23:00 23:00 23:00
u
Error Messages
8.
v
Technical Specifications
9.
;
Warranty
10.
Customer Assistance
11.
400-115-003-B (TH115B_AF) ENG.fm Page 2 Tuesday, February 27, 2007 2:55 PM
Download manual in English (PDF, 1.55 MB)
(Consider the environment and only print this manual if it is really necessary)

Loading…

Rating

Let us know what you think about the Aube TH115 F Thermostat by leaving a product rating. Want to share your experiences with this product or ask a question? Please leave a comment at the bottom of the page.
Are you satisfied with the Aube TH115 F Thermostat?
Yes No
Be the first to rate this product
0 votes

Join the conversation about this product

Here you can share what you think about the Aube TH115 F Thermostat. If you have a question, first carefully read the manual. Requesting a manual can be done by using our contact form.

More about this manual

We understand that it’s nice to have a paper manual for your Aube TH115 F Thermostat. You can always download the manual from our website and print it yourself. If you would like to have an original manual, we recommend you contact Aube. They might be able to provide an original manual. Are you looking for the manual of your Aube TH115 F Thermostat in a different language? Choose your preferred language on our homepage and search for the model number to see if we have it available.

Specifications

Brand Aube
Model TH115 F
Category Thermostats
File type PDF
File size 1.55 MB

All manuals for Aube Thermostats
More manuals of Thermostats

Frequently Asked Questions about Aube TH115 F Thermostat

Our support team searches for useful product information and answers to frequently asked questions. If you find an inaccuracy in our frequently asked questions, please let us know by using our contact form.

What is the dead zone of a thermostat? Verified

Many modern thermostats have a dead zone. If the temperature deviates less than 4°C from the set temperature, the system will not heat or cool. This so called dead zone of the thermostat prevents the system from turning on and off too often, saving energy.

This was helpful (1588) Read more

What is the best place to mount a thermostat? Verified

The best place for a thermostat is approximately 1,5 meter above the ground. Never place the thermostat nead a radiator or other heat emitting equipment or in direct sunlight. Choose a room that is used often. In most cases this is the living room.