prácticas ya que la inflamabilidad es una consideración a tener en cuenta. Se debe seguir el siguiente
procedimiento:
- Retirar el refrigerante.
- Purgar el circuito con gas inerte.
- Evacuar.
- Purgar de nuevo con gas inerte.
- Abrir el circuito cortando o soldando.
La carga del refrigerante se recuperará en los cilindros de recuperación adecuados. El sistema debe
ser "purgado" o enjuagado con OFN para que la unidad sea segura. Es posible que este proceso
necesite repetirse varias veces. No se utilizará aire comprimido ni oxígeno para esta tarea.
El enjuague se logrará salir del vacío en el sistema con nitrógeno sin oxígeno y mientras se continuará
llenando hasta que se alcance la presión máxima de trabajo. A continuación, se ventilará a la atmósfera
y finalmente se tirará hacia el vacío. Este proceso se repetirá hasta que no quede refrigerante dentro
del sistema. Cuando se utilice la carga final de nitrógeno sin oxígeno, el sistema se ventilará a presión
atmosférica para permitir el trabajo. Esta operación es absolutamente vital si se tienen que realizar
operaciones de soldadura en la tubería. Hay que asegurarse de que la salida de la bomba de vacío no
esté cerca de ninguna fuente de ignición y que haya ventilación disponible.
8 PROCEDIMIENTOS DE CARGA
Además de los procedimientos de carga convencionales, se seguirán los siguientes requisitos:
- Comprobar que no se produzca contaminación por parte de diferentes refrigerantes al utilizar
equipos de carga. Las mangueras o líneas deben ser lo más cortas posible para minimizar la cantidad
de refrigerante contenida en ellos.
- Los cilindros deben mantenerse en posición vertical.
- Comprobar que el sistema de refrigeración esté conectado a tierra antes de cargarlo con
refrigerante.
- Etiquetar el sistema cuando la carga se haya completado (si no lo está ya).
- Se deberá tener extremo cuidado para evitar el sobrellenado del sistema de refrigeración.
Antes de recargar el sistema, se someterá a prueba de presión con nitrógeno sin oxígeno. El sistema se
someterá a prueba de fugas al finalizar la carga, pero siempre antes de la puesta en marcha. Se debe
realizar una prueba de seguimiento de fuga antes de abandonar el lugar.
9 DESACTIVACIÓN
Antes de llevar a cabo este procedimiento, es esencial que el técnico esté completamente familiarizado
con el equipo y todos sus detalles. Se recomienda una buena praxis para que todos los refrigerantes
sean recuperados de manera segura. Antes de realizar la labor, se tomará una muestra de aceite y de
refrigerante en caso de que se requiera un análisis previamente a reutilizar el refrigerante recuperado.
Es esencial que haya energía eléctrica disponible antes de comenzar la tarea.
a) Hay que familiarizarse con el equipo y su funcionamiento.
b) Aislar el sistema eléctricamente.
c) Antes de intentar el procedimiento, hay que asegurarse de lo siguiente:
Download manual in English (PDF, 1.87 MB)
(Consider the environment and only print this manual if it is really necessary)

Loading…

Rating

Let us know what you think about the Orbegozo ADRW 125 Air Conditioner by leaving a product rating. Want to share your experiences with this product or ask a question? Please leave a comment at the bottom of the page.
Are you satisfied with the Orbegozo ADRW 125 Air Conditioner?
Yes No
Be the first to rate this product
0 votes

Join the conversation about this product

Here you can share what you think about the Orbegozo ADRW 125 Air Conditioner. If you have a question, first carefully read the manual. Requesting a manual can be done by using our contact form.

More about this manual

We understand that it’s nice to have a paper manual for your Orbegozo ADRW 125 Air Conditioner. You can always download the manual from our website and print it yourself. If you would like to have an original manual, we recommend you contact Orbegozo. They might be able to provide an original manual. Are you looking for the manual of your Orbegozo ADRW 125 Air Conditioner in a different language? Choose your preferred language on our homepage and search for the model number to see if we have it available.

Specifications

Brand Orbegozo
Model ADRW 125
Category Air Conditioners
File type PDF
File size 1.87 MB

All manuals for Orbegozo Air Conditioners
More manuals of Air Conditioners

Frequently Asked Questions about Orbegozo ADRW 125 Air Conditioner

Our support team searches for useful product information and answers to frequently asked questions. If you find an inaccuracy in our frequently asked questions, please let us know by using our contact form.

How often should I clean or replace the filters in my air conditioner? Verified

It's advisable to check the filters of your air conditioner 4 times a year. Dirty filters can be cleaned with the use of a vacuum cleaner or can be washed, depending on which type they are. During maintenance a professional should judge whether it is time to replace the filters.

This was helpful (2746) Read more

What does BTU stand for? Verified

BTU stands for British Thermal Unit. This is unit to indicate the capacity to cool.

This was helpful (987) Read more

Does every air conditioner also function as a dehumidifier? Verified

The cold air produced by an air conditioner often has a relatively low humidity. However, the effect is less than when using an actual dehumidifier. Some air conditioners do have a special feature to dehumidify the air.

This was helpful (753) Read more

What is R-410A? Verified

R-410A is a cooling agent that is used in appliances that cool up to 0°C, like refrigerators and air conditioners. It is the replacement of older cooling agents and does not damage the ozon layer.

This was helpful (518) Read more

Does an air conditioner have a negative influence on air quality? Verified

If the air conditioner has been properly maintained then it will have no influence on air quality. If for example a filter hasn't been replaced for a long time, or other maintenance has not been performed, than an air conditioner can produce dirty air.

This was helpful (372) Read more

Can I place my mobile air conditioner in a cabinet to get it out of sight? Verified

No, absolutely not. A mobile air conditioner needs space to allow airflow and air intake. In a small space the device can overheat.

This was helpful (370) Read more

What is the best place to mount the indoor unit of a split-type air conditioner? Verified

This depends on the space, but in general the following rules can be followed. Make sure that there is nothing obstructing the airflow. Make sure the location is accessible for maintenance. Mount the unit at least 2 meters from the ground.