ADR 122 ADR 128 ADRW 120 ADRW 125
8
estará disponible el equipo de manipulación mecánica, si fuera necesario, para manipular cilindros de
refrigerante;
todo el equipo protector personal estará disponible y se estará usando correctamente; el proceso de
recuperación será supervisado en todo momento por una persona competente; el equipo de
recuperación y los cilindros se ajustan a los estándares apropiados.
d) Bombear el sistema refrigerante, si fuera posible.
e) Si no fuera posible el vacío, hacer un colector para que el refrigerante pueda retirarse de varias
partes del sistema.
f) Hay que asegurarse de que el cilindro esté situado en la balanza antes de que tenga lugar
la recuperación.
g) Arrancar la máquina de recuperación y operar de acuerdo con las instrucciones del fabricante.
h) No sobrecargar los cilindros. (No más del 80% de volumen de carga líquida).
i) No exceder la presión máxima de trabajo del cilindro, ni siquiera temporalmente.
j) Cuando los cilindros se hayan llenado correctamente y se haya completado el proceso, hay que
verificar que los cilindros y el equipo se retiren del sitio rápidamente y que todas las válvulas de
aislamiento del equipo estén cerradas.
k) El refrigerante recuperado no debe cargarse en otro sistema de refrigeración, a menos que se haya
limpiado y haya sido verificado.
10 ETIQUETADO
El equipo deberá estar etiquetado indicando que ha sido desactivado y vaciado de refrigerante. La
etiqueta deberá estar fechada y firmada. Verificar que haya etiquetas en el equipo que indiquen que el
equipo contiene refrigerante inflamable.refrigerant.
11 RECUPERACIÓN
Al retirar refrigerante de un sistema, ya sea para servicio o desmantelamiento, se recomienda una
buena práctica que todos los refrigerantes se eliminen de manera segura.
Al transferir refrigerante a los cilindros, hay que asegurarse de que solo se empleen cilindros de
recuperación de refrigerante apropiados. Hay que asegurarse de que el número correcto de cilindros
esté disponible para mantener la carga total del sistema. Todos los cilindros que se utilizarán estarán
designados para el refrigerante recuperado y estarán etiquetados para dicho refrigerante (es decir,
cilindros especiales para la recuperación de refrigerante). Los cilindros deberán estar completos con
una válvula de alivio de presión y llaves de paso asociadas en buen estado de funcionamiento. Los
cilindros de recuperación vacíos se evacuarán y, si es posible, se enfriarán antes de que se produzca la
recuperación.
El equipo de recuperación deberá estar en buen estado de funcionamiento (teniendo disponible un
conjunto de instrucciones sobre dicho equipo) y deberá ser adecuado para recuperar los refrigerantes
inflamables.
Además, un conjunto de balanzas calibradas debe estar disponible y en buen funcionamiento. Las
mangueras deberán estar completas con acoplamientos de desconexión sin fugas y en buenas
condiciones. Antes de usar el equipo de recuperación, hay que verificar que esté funcionando
correctamente, que se haya mantenido adecuadamente y que sus componentes eléctricos asociados
Download manual in English (PDF, 1.87 MB)
(Consider the environment and only print this manual if it is really necessary)

Loading…

Rating

Let us know what you think about the Orbegozo ADRW 125 Air Conditioner by leaving a product rating. Want to share your experiences with this product or ask a question? Please leave a comment at the bottom of the page.
Are you satisfied with the Orbegozo ADRW 125 Air Conditioner?
Yes No
Be the first to rate this product
0 votes

Join the conversation about this product

Here you can share what you think about the Orbegozo ADRW 125 Air Conditioner. If you have a question, first carefully read the manual. Requesting a manual can be done by using our contact form.

More about this manual

We understand that it’s nice to have a paper manual for your Orbegozo ADRW 125 Air Conditioner. You can always download the manual from our website and print it yourself. If you would like to have an original manual, we recommend you contact Orbegozo. They might be able to provide an original manual. Are you looking for the manual of your Orbegozo ADRW 125 Air Conditioner in a different language? Choose your preferred language on our homepage and search for the model number to see if we have it available.

Specifications

Brand Orbegozo
Model ADRW 125
Category Air Conditioners
File type PDF
File size 1.87 MB

All manuals for Orbegozo Air Conditioners
More manuals of Air Conditioners

Frequently Asked Questions about Orbegozo ADRW 125 Air Conditioner

Our support team searches for useful product information and answers to frequently asked questions. If you find an inaccuracy in our frequently asked questions, please let us know by using our contact form.

How often should I clean or replace the filters in my air conditioner? Verified

It's advisable to check the filters of your air conditioner 4 times a year. Dirty filters can be cleaned with the use of a vacuum cleaner or can be washed, depending on which type they are. During maintenance a professional should judge whether it is time to replace the filters.

This was helpful (2746) Read more

What does BTU stand for? Verified

BTU stands for British Thermal Unit. This is unit to indicate the capacity to cool.

This was helpful (987) Read more

Does every air conditioner also function as a dehumidifier? Verified

The cold air produced by an air conditioner often has a relatively low humidity. However, the effect is less than when using an actual dehumidifier. Some air conditioners do have a special feature to dehumidify the air.

This was helpful (753) Read more

What is R-410A? Verified

R-410A is a cooling agent that is used in appliances that cool up to 0°C, like refrigerators and air conditioners. It is the replacement of older cooling agents and does not damage the ozon layer.

This was helpful (518) Read more

Does an air conditioner have a negative influence on air quality? Verified

If the air conditioner has been properly maintained then it will have no influence on air quality. If for example a filter hasn't been replaced for a long time, or other maintenance has not been performed, than an air conditioner can produce dirty air.

This was helpful (372) Read more

Can I place my mobile air conditioner in a cabinet to get it out of sight? Verified

No, absolutely not. A mobile air conditioner needs space to allow airflow and air intake. In a small space the device can overheat.

This was helpful (370) Read more

What is the best place to mount the indoor unit of a split-type air conditioner? Verified

This depends on the space, but in general the following rules can be followed. Make sure that there is nothing obstructing the airflow. Make sure the location is accessible for maintenance. Mount the unit at least 2 meters from the ground.

This was helpful (370) Read more
Manual Orbegozo ADRW 125 Air Conditioner

Related products

Related categories