1) Assemble mounting screws to backpan using hexnut.
2) At the center of the backpan are knockout slots. Remove the set that
matches your outlet box.
3) Secure the backpan to the outlet box.
4) Anchor the backpan to the wall using the set of holes at each end of
fixture using wood screws, toggle bolts, plastic anchors, etc.
5) Turn off power.
6) Grounding instructions: (See Illus. A or B).
A) On fixtures where mounting strap is provided with a hole and two
raised dimples. Wrap ground wire from outlet box around green
ground screw, and thread into hole.
B) On fixtures where a cupped washer is provided. Attach ground
wire from outlet box under cupped washer and green ground
screw, and thread into mounting strap.
If fixture is provided with ground wire. Connect fixture ground wire to outlet
box ground wire with wire connector (not provided.) after following the
above steps. Never connect ground wire to black or white power supply
wires.
7) Make wire connections (connectors not provided). Reference chart
below for correct connections and wire accordingly.
8) Carefully push wire connections back into outlet box making sure all
connections remain secure.
9) Slip faceplate over mounting screws and backpan.
NOTE: Be certain wires do not get pinched between backpan
and faceplate.
10) Secure faceplate to backpan using threaded balls.
11) Slip glass over socket at end of arm and allow to seat on socket cup.
GREEN GROUND
SCREW
CUPPED
WASHER
A
B
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
(NOT PROVIDED)
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
Connect Black or
Red Supply Wire to:
Connect
White Supply Wire to:
Black White
*Parallel cord (round & smooth)
*Parallel cord (square & ridged)
Clear, Brown, Gold or Black
without tracer
Clear, Brown, Gold or Black
with tracer
Insulated wire (other than green)
with copper conductor
Insulated wire (other than green)
with silver conductor
*Note: When parallel wires (SPT I & SPT II)
are used. The neutral wire is square shaped
or ridged and the other wire will be round in
shape or smooth (see illus.)
Neutral Wire
1) Ensamble los tornillos de montaje a la placa de montaje usando la tuerca
hexagonal.
2) En el centro de la placa de montaje se encuentran orificios ciegos.
Retire el juego que corresponda con su caja de salida.
3) Fije la placa de montaje a la caja de salida.
4) Ancle la placa de montaje a la pared usando la serie de orificios en cada
extremo del artefacto usando tornillos de madera, pernos de lengüeta,
anclajes de plástico, etc.
5) Desconecte la corriente.
6) Instrucciones de conexión a tierra solamente para los Estados
Unidos. (Vea la ilustracion A o B).
A) En las lámparas que tienen el fleje, de montaje con un agujero y
dos hoyue los realzados. Enrollar el alambre a tierra de la caja
tomacorriente alrededor del tornillo verde y pasarlo por el aquiero.
B) En las lámparas con una arandela acopada. Fijar el alambre a
tierra de la caja tomacorriente del ajo de la arandela acoada y
tornillo verde, y paser por el fleje de montaje.
Si la lámpara viene con alambre a tierra. Conecter el alambre a tierra de la
lámpara al alambre a tierra de la caja tomacorriente con un conector de
alambres (no incluido) espués de seguir los pasos anteriores. Nunca
conectar el alambra a tierra a los alambres eléctros negro o blanco.
7) Haga les conexiones de los alambres (no se proveen los connectores.)
La tabla de referencia de abajo indica las conexiones correctas y los
alambres correspondientes.
8) Coloque con cuidado nuevamente las conexiones de alambre en la caja
de salida, asegurando que todas las conexiones estén seguras.
9) Deslice la placa de sujeción sobre los tornillos de montaje y la placa de
montaje.
NOTA: Asegúrese que los alambres no queden oprimidos entre la placa
de montaje y la placa de sujeción (chapa de pared).
10) Fije la placa de sujeción a la placa de montaje usando las esferas
roscadas.
11) Deslice el vidrio sobre el portalámpara al final del brazo y deje que
descanse en el portalámpara.
ARANDELA
CONCAVA
A
B
TIERRA DE LA
CAJA DE SALIDA
TORNILLO DE TIERRA,
VERDE
DEPRESIONES
TIERRA
ARTEFACTO
CONECTOR DE ALAMBRE
(NO SE PROVEE)
TIERRA DE LA
CAJA DE SALIDA
TORNILLO DE TIERRA,
VERDE
TIERRA
ARTEFACTO
Conectar el alambre de
suministro negro o rojo al
Conectar el alambre de
suministro blanco al
Negro Blanco
*Cordon paralelo (redondo y liso)
*Cordon paralelo (cuadrado y estriado)
Claro, marrón, amarillio o negro
sin hebra identificadora
Claro, marrón, amarillio o negro
con hebra identificadora
Alambre aislado (diferente del verde)
con conductor de cobre
Alambre aislado (diferente del
verde) con conductor de plata
*Nota: Cuando se utiliza alambre paralelo
(SPT I y SPT II). El alambre neutro es de forma
cuadrada o estriada y el otro alambre será de
forma redonda o lisa. (Vea la ilustracíón).
Hilo Neutral
Date Issued: 5/19/06
IS-5097-US
FACEPLATE
PLACA DE SUJECIÓN
THREADED BALL
ESFERA ROSCADA
BACKPAN
PLACA DE APOYO
OUTLET BOX
CAJA DE SALIDA
MOUNTING SCREW
TORNILLO DE MONTAJE
OUTLET BOX SCREW
TORNILLO DE CAJA
DE SALIDA
KNOCKOUT SLOTS
MUESCAS DE
AGUJERO CIEGO
HEXNUT
TUERCA HEXAGONAL
Download manual in English (PDF, 0.3 MB)
(Consider the environment and only print this manual if it is really necessary)

Loading…

Rating

Let us know what you think about the Kichler 5098CH Eileen Lamp by leaving a product rating. Want to share your experiences with this product or ask a question? Please leave a comment at the bottom of the page.
Are you satisfied with the Kichler 5098CH Eileen Lamp?
Yes No
Be the first to rate this product
0 votes

Join the conversation about this product

Here you can share what you think about the Kichler 5098CH Eileen Lamp. If you have a question, first carefully read the manual. Requesting a manual can be done by using our contact form.

More about this manual

We understand that it’s nice to have a paper manual for your Kichler 5098CH Eileen Lamp. You can always download the manual from our website and print it yourself. If you would like to have an original manual, we recommend you contact Kichler. They might be able to provide an original manual. Are you looking for the manual of your Kichler 5098CH Eileen Lamp in a different language? Choose your preferred language on our homepage and search for the model number to see if we have it available.

Specifications

Brand Kichler
Model 5098CH Eileen
Category Lamps
File type PDF
File size 0.3 MB

All manuals for Kichler Lamps
More manuals of Lamps

Frequently Asked Questions about Kichler 5098CH Eileen Lamp

Our support team searches for useful product information and answers to frequently asked questions. If you find an inaccuracy in our frequently asked questions, please let us know by using our contact form.

Is all LED lighting dimmable? Verified

No, not all LED lights are dimmable. This is indicated on the packaging or the light itself.

This was helpful (462) Read more

I put a new light in my lamp but it won't turn on, why is that? Verified

Some lamps are made for light sources of a specific wattage. When a light source is inserted that requires a higher wattage than the lamp can provide, the light may not turn on. If the lamp delivers a much higher wattage than what the light source is made for, the light source can burn out.

This was helpful (315) Read more

Why is the colour of light important? Verified

There generally are two kinds of light, warm light and cold light. Cold light keeps you sharp and awake. Warm light has a relaxing effect. The warmth of the light is measured in Kelvin and is indicated on the packaging of the lamp itself.

This was helpful (255) Read more

What is lumen? Verified

Lumen is a measuring unit for the total amount of visible light emitted by a source.

This was helpful (190) Read more

What screw bases exist? Verified

Worldwide there many types of sockets, but most used are those based on the Edison screw, indicated with the letter E. In most countries screw bases E27 and E14 are standard. In the United States E26, E17, E12 and E10 are standard.

This was helpful (142) Read more

What do watts say about my lamp? Verified

Watt is a measuring unit for electricity consumption. Lamps that produce more light, generally use more Watt, but for comparing light output you should always use lumen.

This was helpful (113) Read more

What is LED? Verified

LED stands for Light-Emitting Diode. By running power through a semiconductor in the right direction, light is emitted.

This was helpful (98) Read more
Manual Kichler 5098CH Eileen Lamp