Manual Infiniton PAC-W12 Air Conditioner

Need a manual for your Infiniton PAC-W12 Air Conditioner? Below you can view and download the PDF manual for free in English. This product currently has 7 frequently asked questions, 0 comments and has 0 votes. If this is not the manual you want, please contact us.

Is your product defective and the manual offers no solution? Go to a Repair Café for free repair services.

Manual

Loading…

Advertencia adicional para el aparato con gas refrigerante R290 (consulte la placa
de características para el tipo de gas refrigerante utilizado)
PRECAUCION EN EL FUEGO
LEA EL MANUAL CUIDADOSAMENTE ANTES DE USAR EL APARATO
El gas refrigerante R290 cumple con las directivas medioambientales
europeas. Este aparato contiene aproximadamente 160 g de gas refrigerante
R290.
El aparato debe instalarse, operarse y almacenarse en una habitación con una
superficie de más de 7.7 m2.
Instrucciones de reparación de electrodomésticos que
contienen R 290
1. Cheques a la zona.
Antes de comenzar a trabajar en sistemas que contienen refrigerantes inflamables, se requieren
controles de seguridad para garantizar que se minimice el riesgo de ignición. Para la reparación del
sistema de refrigeración, se deben completar las siguientes precauciones antes de realizar trabajos en
el sistema.
2. Procedimiento de trabajo
El trabajo debe realizarse bajo un procedimiento controlado para minimizar el riesgo de que haya un
gas o vapor inflamable mientras se realiza el trabajo.
3. Área de trabajo general.
Todo el personal de mantenimiento y otras personas que trabajan en el área local deben recibir
instrucciones sobre la naturaleza del trabajo que se está llevando a cabo. Se evitará el trabajo en
espacios confinados.
4. Comprobando la presencia de refrigerante
El área debe verificarse con un detector de refrigerante adecuado antes y durante el trabajo, para
garantizar que el técnico tenga conocimiento de atmósferas potencialmente tóxicas o inflamables.
Asegúrese de que el equipo de detección de fugas que se está utilizando sea adecuado para el uso
con todos los refrigerantes aplicables, es decir, que no produzcan chispas, que estén adecuadamente
sellados o sean intrínsecamente seguros.
5. Presencia de extintor de incendios.
Si se debe realizar algún trabajo en caliente en el equipo de refrigeración o en cualquier pieza
asociada,
El equipo apropiado de extinción de incendios debe estar disponible a mano. Tenga un extintor de
polvo seco o CO2 adyacente al área de carga.
6. No hay fuentes de ignición.
Ninguna persona que lleve a cabo trabajos en relación con un sistema de refrigeración que implique la
exposición de ningún tipo de tubería deberá utilizar fuentes de ignición de manera que pueda provocar
un incendio o una explosión. Todas las posibles fuentes de ignición, incluido el consumo de cigarrillos,
deben mantenerse lo suficientemente lejos del lugar de instalación, reparación, eliminación y
eliminación, durante el cual es posible que se libere refrigerante al espacio circundante. Antes de
realizar el trabajo, se debe inspeccionar el área alrededor del equipo para asegurarse de que no haya
peligros inflamables o riesgos de ignición. Se mostrarán letreros de "No fumar".
Download manual in English (PDF, 13.23 MB)
(Consider the environment and only print this manual if it is really necessary)

Loading…

Rating

Let us know what you think about the Infiniton PAC-W12 Air Conditioner by leaving a product rating. Want to share your experiences with this product or ask a question? Please leave a comment at the bottom of the page.
Are you satisfied with the Infiniton PAC-W12 Air Conditioner?
Yes No
Be the first to rate this product
0 votes

Join the conversation about this product

Here you can share what you think about the Infiniton PAC-W12 Air Conditioner. If you have a question, first carefully read the manual. Requesting a manual can be done by using our contact form.

More about this manual

We understand that it’s nice to have a paper manual for your Infiniton PAC-W12 Air Conditioner. You can always download the manual from our website and print it yourself. If you would like to have an original manual, we recommend you contact Infiniton. They might be able to provide an original manual. Are you looking for the manual of your Infiniton PAC-W12 Air Conditioner in a different language? Choose your preferred language on our homepage and search for the model number to see if we have it available.

Specifications

Brand Infiniton
Model PAC-W12
Category Air Conditioners
File type PDF
File size 13.23 MB

All manuals for Infiniton Air Conditioners
More manuals of Air Conditioners

Frequently Asked Questions about Infiniton PAC-W12 Air Conditioner

Our support team searches for useful product information and answers to frequently asked questions. If you find an inaccuracy in our frequently asked questions, please let us know by using our contact form.

How often should I clean or replace the filters in my air conditioner? Verified

It's advisable to check the filters of your air conditioner 4 times a year. Dirty filters can be cleaned with the use of a vacuum cleaner or can be washed, depending on which type they are. During maintenance a professional should judge whether it is time to replace the filters.

This was helpful (2746) Read more

What does BTU stand for? Verified

BTU stands for British Thermal Unit. This is unit to indicate the capacity to cool.

This was helpful (987) Read more

Does every air conditioner also function as a dehumidifier? Verified

The cold air produced by an air conditioner often has a relatively low humidity. However, the effect is less than when using an actual dehumidifier. Some air conditioners do have a special feature to dehumidify the air.

This was helpful (753) Read more

What is R-410A? Verified

R-410A is a cooling agent that is used in appliances that cool up to 0°C, like refrigerators and air conditioners. It is the replacement of older cooling agents and does not damage the ozon layer.

This was helpful (518) Read more

Does an air conditioner have a negative influence on air quality? Verified

If the air conditioner has been properly maintained then it will have no influence on air quality. If for example a filter hasn't been replaced for a long time, or other maintenance has not been performed, than an air conditioner can produce dirty air.

This was helpful (372) Read more

Can I place my mobile air conditioner in a cabinet to get it out of sight? Verified

No, absolutely not. A mobile air conditioner needs space to allow airflow and air intake. In a small space the device can overheat.

This was helpful (370) Read more

What is the best place to mount the indoor unit of a split-type air conditioner? Verified

This depends on the space, but in general the following rules can be followed. Make sure that there is nothing obstructing the airflow. Make sure the location is accessible for maintenance. Mount the unit at least 2 meters from the ground.

This was helpful (370) Read more