Antes de la Iniciación
Para evitar daños, coloque la unidad en posición vertical durante al menos 24 horas antes del
inicio. Asegúrese de que la salida de aire y la entrada de aire nunca estén bloqueadas.
Solo opere la unidad en una superficie horizontal para asegurar que no salga agua.
Advertencias
No exceda la señalización de impedancia superior a 0.236ohm en el suministro al que está conectado el
aparato. El incumplimiento de las normas puede llevar a la autoridad de suministro a imponer restricciones a
la conexión. Consulte a su autoridad de suministro de energía si el uso del equipo supera los 0,236 ohmios.
Cualquier persona que esté involucrada en trabajar o romper un refrigerante en un circuito de refrigerante
debe tener un certificado válido vigente de una autoridad de evaluación acreditada en la industria. Lo que
autoriza su competencia para manejar la seguridad de los refrigerantes de acuerdo con las especificaciones
de evaluación reconocidas por la industria.
Recuerde el entorno cuando deseche el embalaje alrededor del dispositivo y cuando el dispositivo haya
llegado a su fecha.
Warning Una advertencia de que el aparato debe almacenarse en un área bien ventilada donde el tamaño
corresponda al área de la habitación como se especifica para la operación.
El aparato debe almacenarse de manera que se eviten daños mecánicos.
Información para espacios donde se permiten tuberías de refrigerante, incluidas declaraciones
que la instalación de las tuberías se mantenga al mínimo;
la tubería debe estar protegida contra daños físicos y, en el caso de refrigerantes inflamables, no debe instalarse
en un espacio sin ventilación;
que se observará el cumplimiento de la normativa nacional de gas;
que las conexiones mecánicas sean accesibles para fines de mantenimiento;
que, para los aparatos que contienen refrigerantes inflamables, el área mínima del piso de la habitación debe
mencionarse en forma de mesa o de una sola figura sin hacer referencia a una fórmula;
Una advertencia para mantener las aberturas de ventilación necesarias libres de obstrucciones;
Un aviso de que el servicio de mantenimiento se realizará solo según lo recomendado por el fabricante;
Una advertencia de que los conductos conectados a un aparato no deben contener una fuente de ignición
potencial;
Cuando se enciende el aire acondicionado portátil o el deshumidificador, el ventilador puede funcionar
continuamente estable en condiciones normales para proporcionar el volumen de aire mínimo de 100 m3 / h,
incluso cuando el compresor
Está cerrado debido al controlador de temperatura.
No perforar o quemar.
Use solo los implementos recomendados por el fabricante para descongelar o limpiar
No perfore ninguno de los componentes del circuito de refrigerante. El gas refrigerante puede ser inodoro
Tenga cuidado al guardar el aparato para evitar fallos mecánicos.
Solo las personas autorizadas por una agencia acreditada que certifiquen su competencia para manejar
refrigerantes de conformidad con la legislación del sector deben trabajar en el circuito de refrigerante.
Todas las reparaciones deben realizarse de acuerdo con las recomendaciones del fabricante.
El mantenimiento y las reparaciones que requieran la asistencia de otro personal calificado deben
realizarse bajo la supervisión de especialistas en el uso de refrigerantes inflamables.
No perfore ninguno de los componentes del circuito de refrigerante. El gas refrigerante puede ser inodoro
Download manual in English (PDF, 13.23 MB)
(Consider the environment and only print this manual if it is really necessary)

Loading…

Rating

Let us know what you think about the Infiniton PAC-W12 Air Conditioner by leaving a product rating. Want to share your experiences with this product or ask a question? Please leave a comment at the bottom of the page.
Are you satisfied with the Infiniton PAC-W12 Air Conditioner?
Yes No
Be the first to rate this product
0 votes

Join the conversation about this product

Here you can share what you think about the Infiniton PAC-W12 Air Conditioner. If you have a question, first carefully read the manual. Requesting a manual can be done by using our contact form.

More about this manual

We understand that it’s nice to have a paper manual for your Infiniton PAC-W12 Air Conditioner. You can always download the manual from our website and print it yourself. If you would like to have an original manual, we recommend you contact Infiniton. They might be able to provide an original manual. Are you looking for the manual of your Infiniton PAC-W12 Air Conditioner in a different language? Choose your preferred language on our homepage and search for the model number to see if we have it available.

Specifications

Brand Infiniton
Model PAC-W12
Category Air Conditioners
File type PDF
File size 13.23 MB

All manuals for Infiniton Air Conditioners
More manuals of Air Conditioners

Frequently Asked Questions about Infiniton PAC-W12 Air Conditioner

Our support team searches for useful product information and answers to frequently asked questions. If you find an inaccuracy in our frequently asked questions, please let us know by using our contact form.

How often should I clean or replace the filters in my air conditioner? Verified

It's advisable to check the filters of your air conditioner 4 times a year. Dirty filters can be cleaned with the use of a vacuum cleaner or can be washed, depending on which type they are. During maintenance a professional should judge whether it is time to replace the filters.

This was helpful (2746) Read more

What does BTU stand for? Verified

BTU stands for British Thermal Unit. This is unit to indicate the capacity to cool.

This was helpful (987) Read more

Does every air conditioner also function as a dehumidifier? Verified

The cold air produced by an air conditioner often has a relatively low humidity. However, the effect is less than when using an actual dehumidifier. Some air conditioners do have a special feature to dehumidify the air.

This was helpful (753) Read more

What is R-410A? Verified

R-410A is a cooling agent that is used in appliances that cool up to 0°C, like refrigerators and air conditioners. It is the replacement of older cooling agents and does not damage the ozon layer.

This was helpful (518) Read more

Does an air conditioner have a negative influence on air quality? Verified

If the air conditioner has been properly maintained then it will have no influence on air quality. If for example a filter hasn't been replaced for a long time, or other maintenance has not been performed, than an air conditioner can produce dirty air.

This was helpful (372) Read more

Can I place my mobile air conditioner in a cabinet to get it out of sight? Verified

No, absolutely not. A mobile air conditioner needs space to allow airflow and air intake. In a small space the device can overheat.

This was helpful (370) Read more

What is the best place to mount the indoor unit of a split-type air conditioner? Verified

This depends on the space, but in general the following rules can be followed. Make sure that there is nothing obstructing the airflow. Make sure the location is accessible for maintenance. Mount the unit at least 2 meters from the ground.