Manual Horstmann ElectriSaver E30 Thermostat

Need a manual for your Horstmann ElectriSaver E30 Thermostat? Below you can view and download the PDF manual for free in English. This product currently has 2 frequently asked questions, 2 comments and has 0 votes. If this is not the manual you want, please contact us.

Is your product defective and the manual offers no solution? Go to a Repair Café for free repair services.

Manual

Loading…

EELLEECCTTRRIISSAAVVEERR UUSSEERR
AANNDD IINNSSTTAALLLLAATTIIOONN IINNSSTTRRUUCCTTIIOONNSS
SSEERRVVIICCEE AANNDD RREEPPAAIIRR
The Electrisaver is NOT user serviceable. Please do not dismantle the unit.
In the unlikely event of a fault developing please a local heating engineer or a qualified electrician.
LEAFLET No P80502
ISSUE 3
PPaaggee 44
Horstmann Controls Limited
Bristol
BS4 1UP
Website: www.horstmann.co.uk
HHoorrssttmmaannnnss EElleeccttrriissaavveerr -- PPuusshh bbuuttttoonn bboooosstt ttiimmeerr
can be used to
control immersion elements up to 3Kw or as as override/extension
timer for Central heating systems.
INSTALLATION AND CONNECTION SHOULD ONLY BE CARRIED OUT BY A SUITABLY QUALIFIED PERSON
AND IN ACCORDANCE WITH THE CURRENT EDITION OF THE IEE WIRING REGULATIONS.
WWAARRNNIINNGG :: IISSOOLLAATTEE MMAAIINNSS SSUUPPPPLLYY BBEEFFOORREE CCOOMMMMEENNCCIINNGG IINNSSTTAALLLLAATTIIOONN
EENNSSUURREE TTHHEE UUNNIITT IISS PPRROOPPEERRLLYY EEAARRTTHHEEDD..
Means of disconnection from the supply having at least 3mm contact separation in both poles must be
incorporated in the fixed wiring.
We recommend a separate fused circuit from the consumer unit (24 Hour supply) protected by a 15
amp HRC fuse or, preferably a 16 amp MCB. In some cases immersion heater failure can damage the
Electrisaver. Installation of a 100 mA RCD will provide additional protection for the unit. If the
Electrisaver is to be connected to a ring main then the spur feeding the controller should be
protected in the same way.
The Electrisaver is NOT suitable for mounting on an unearthed metal surface.
PPaaggee 11
IINNSSTTAALLLLAATTIIOONN
SSPPEECCIIFFIICCAATTIIOONN
PPuurrppoossee ooff ccoonnttrrooll::
Electronic Timer (Independently mounted)
CCllaassssiiffiiccaattiioonn
: Type 1C Action (RL1)
CCoonnttaacctt rraattiinngg::
13A 230V AC Suitable for load up to 3Kw
PPoowweerr ssuuppppllyy::
230V AC 50Hz
OOppeerraattiinngg tteemmppeerraattuurree rraannggee::
0
o
C to 35
o
C
SShhoocckk pprrootteeccttiioonn::
Class 1 (Live parts enclosed)
DDiirrtt pprrootteeccttiioonn::
Normal situations.
EEnncclloossuurree pprrootteeccttiioonn::
IP30
IInnddeeppeennddeennttllyy mmoouunntteedd ccoonnttrrooll ffoorr ssuurrffaaccee mmoouunnttiinngg..
OOppeerraattiinngg ttiimmee lliimmiittaattiioonn::
Intermittent
CCaassee mmaatteerriiaall::
Thermoplastic, flame retardant
DDiimmeennssiioonnss::
87mm x 87mm x 16mm (Flush mounted)
51mm (Surface mounted)
MMoouunnttiinngg::
Single gang surface moulded box (35mm minimum)
Single gang mounting box
BBoooosstt PPeerriioodd::
Model E15 - 15min/30min/60min
Model E30 - 30min/1 Hour/2Hour
TTiimmiinngg AAccccuurraaccyy::
+/- 5%
UUSSEERR IINNSSTTRRUUCCTTIIOONNSS
To use the Electrisaver simply press the BOOST button in quick succession until the indicator light for
the required boost period is illuminated (see table below).
To cancel a boost period press the BOOST button continuously until ALL the indicator lights are OFF.
Keeping the boost button depressed will cancel any Boost period.
When the Boost is activated the indicator light will ‘countdown’ showing the approximate duration of
the Boost period remaining.
BOOST PERIOD
PRESS BOOST BUTTON TO SELECT LENGTH OF REQUIRED BOOST.
BUTTON PRESS #1 #2 #3
Electrisaver E15 15min 30min 60min
Electrisaver E30 30min 1 Hour 2 Hour
Download manual in English (PDF, 0.09 MB)
(Consider the environment and only print this manual if it is really necessary)

Loading…

Rating

Let us know what you think about the Horstmann ElectriSaver E30 Thermostat by leaving a product rating. Want to share your experiences with this product or ask a question? Please leave a comment at the bottom of the page.
Are you satisfied with the Horstmann ElectriSaver E30 Thermostat?
Yes No
Be the first to rate this product
0 votes

Join the conversation about this product

Here you can share what you think about the Horstmann ElectriSaver E30 Thermostat. If you have a question, first carefully read the manual. Requesting a manual can be done by using our contact form.

Jack Cyprus 10-09-2021
I want electricity to be turned on for time i needed, and than to turn on the timer. Is there any option at this device to leave electricity on for a couple of days and than to turn on the timer, without unmounting the device?

reply | This was helpful (1)
Alastair Cochrane 25-10-2022
My E30 runs ok automatically but I have no idea how it's set or even when and how it decides to operate. Can anyone clarify what is happening?

reply | This was helpful (1)

More about this manual

We understand that it’s nice to have a paper manual for your Horstmann ElectriSaver E30 Thermostat. You can always download the manual from our website and print it yourself. If you would like to have an original manual, we recommend you contact Horstmann. They might be able to provide an original manual. Are you looking for the manual of your Horstmann ElectriSaver E30 Thermostat in a different language? Choose your preferred language on our homepage and search for the model number to see if we have it available.

Specifications

Brand Horstmann
Model ElectriSaver E30
Category Thermostats
File type PDF
File size 0.09 MB

All manuals for Horstmann Thermostats
More manuals of Thermostats

Frequently Asked Questions about Horstmann ElectriSaver E30 Thermostat

Our support team searches for useful product information and answers to frequently asked questions. If you find an inaccuracy in our frequently asked questions, please let us know by using our contact form.

What is the dead zone of a thermostat? Verified

Many modern thermostats have a dead zone. If the temperature deviates less than 4°C from the set temperature, the system will not heat or cool. This so called dead zone of the thermostat prevents the system from turning on and off too often, saving energy.

This was helpful (1588) Read more

What is the best place to mount a thermostat? Verified

The best place for a thermostat is approximately 1,5 meter above the ground. Never place the thermostat nead a radiator or other heat emitting equipment or in direct sunlight. Choose a room that is used often. In most cases this is the living room.

This was helpful (990) Read more
Manual Horstmann ElectriSaver E30 Thermostat

Related products

Related categories