Manual Emerson 1F85CA-0471 Thermostat

Need a manual for your Emerson 1F85CA-0471 Thermostat? Below you can view and download the PDF manual for free in English. This product currently has 2 frequently asked questions, 0 comments and has 0 votes. If this is not the manual you want, please contact us.

Is your product defective and the manual offers no solution? Go to a Repair Café for free repair services.

Manual

Loading…

2
INSTALLATION
Thermostat installation and all components of the
control system shall conform to Class II circuits per
the NEC code.
WARNING
!
Remove Old Thermostat
A standard heat/cool thermostat consists of three basic parts:
1. The cover, which may be either a snap-on or hinge type.
2. The base, which is removed by loosening all captive
screws.
3. The switching subbase, which is removed by unscrewing
the mounting screws that hold it on the wall or adapter
plate. Before removing wires from old thermostat,
label each wire with the terminal designation from
which it was attached. Disconnect the wires from the
old thermostat one at a time. Do not let wires fall back
into the wall.
Installing New Thermostat
1. Pull the thermostat body off the thermostat base. Forcing
or prying on the thermostat will cause damage to the unit.
2. Place base over hole in wall and mark mounting hole
locations on wall using base as a template.
3. Move base out of the way. Drill mounting holes. If you
are using existing mounting holes and the holes drilled
are too large and do not allow you to tighten base snug-
ly, use plastic screw anchors to secure the base.
4. Fasten base snugly to wall using mounting holes shown
in Figure 2 and two mounting screws. Leveling is for
appearance only and will not affect thermostat operation.
5. Connect wires to terminal block on base.
6. Push excess wire into wall and plug hole with a fi re re-
sistant material (such as fi berglass insulation) to prevent
drafts from affecting thermostat operation.
7. Carefully line the thermostat up with the base and snap
into place.
Batteries
2 “AA” alkaline batteries are included with the thermostat.
To install the batteries, pull the battery door as shown by the
arrow and lift open. Using the polarity indicated inside the bat-
tery door, insert the batteries. To close the battery door, swing
the door down while pulling in the direction of arrow. Once
fully down, snap the door back into position. To replace the
batteries, set system to OFF.
Thermostat can be powered by system AC power or Battery.
If
is displayed, the thermostat is battery powered. If
is not displayed, thermostat is system powered with optional
battery back-up. When battery power remaining is approxi-
mately half, the
will be displayed. When “Change
is displayed, install fresh “AA” alkaline batteries immediately.
For best results, replace all batteries with new premium brand
alkaline batteries such as Duracell
®
or Energizer
®
. We recom-
mend replacing batteries every 2 years. If the home is going
to be unoccupied for an extended period (over 3 months) and
is displayed, the batteries should be replaced before
leaving. When less than two months of battery life remain, the
setpoint temperature will offset by 10 degrees (10 degrees
cooler in Heat mode / 10 degrees warmer in Cool mode). If
offset occurs, the normal setpoint can be manually reset with
or . Another offset will occur within two days if batter-
ies are not replaced.
“AA” Alkaline Batteries
Figure 1 – Battery door shown open
Mounting
Hole
Mounting
Hole
Place Level
across
Mounting Tabs
(for appearance only)
Place Level
across
Mounting Tabs
(for appearance only)
Figure 2 – Thermostat base and rear view of thermostat
WIRING CONNECTIONS
Refer to equipment manufacturers’ instructions for specifi c
system wiring information. After wiring, see CONFIGURATION
section for proper thermostat confi guration.
Refer to fi gure 3 through 6 for wiring diagram specifi cations.
Terminal
Designation Description
L .............. Heat pump malfunction indicator for systems
with malfunction connection or Comfort Alert signal
O .............. Changeover valve for heat pump energized
constantly in cooling
B .............. Changeover valve for heat pump energized
constantly in heating
Y .............. Compressor Relay
Y2 ............. 2nd Stage Compressor
Terminal
Designation Description
W/E ............Heat Relay/Emergency Heat Relay (Stage 1)
W2 .............2nd Stage Heat (3rd Stage Heat in HP 2)
G ..............Fan Relay
RH .............Power for Heating
RC .............Power for Cooling
C ..............Common wire from secondary side of cooling system
transformer or heat only system transformer
6...............3 Wire Zone Valve – Energized when no call for Heat
TERMINAL DESIGNATION DESCRIPTIONS
Download manual in English (PDF, 1.31 MB)
(Consider the environment and only print this manual if it is really necessary)

Loading…

Rating

Let us know what you think about the Emerson 1F85CA-0471 Thermostat by leaving a product rating. Want to share your experiences with this product or ask a question? Please leave a comment at the bottom of the page.
Are you satisfied with the Emerson 1F85CA-0471 Thermostat?
Yes No
Be the first to rate this product
0 votes

Join the conversation about this product

Here you can share what you think about the Emerson 1F85CA-0471 Thermostat. If you have a question, first carefully read the manual. Requesting a manual can be done by using our contact form.

More about this manual

We understand that it’s nice to have a paper manual for your Emerson 1F85CA-0471 Thermostat. You can always download the manual from our website and print it yourself. If you would like to have an original manual, we recommend you contact Emerson. They might be able to provide an original manual. Are you looking for the manual of your Emerson 1F85CA-0471 Thermostat in a different language? Choose your preferred language on our homepage and search for the model number to see if we have it available.

Specifications

Brand Emerson
Model 1F85CA-0471
Category Thermostats
File type PDF
File size 1.31 MB

All manuals for Emerson Thermostats
More manuals of Thermostats

Frequently Asked Questions about Emerson 1F85CA-0471 Thermostat

Our support team searches for useful product information and answers to frequently asked questions. If you find an inaccuracy in our frequently asked questions, please let us know by using our contact form.

What is the dead zone of a thermostat? Verified

Many modern thermostats have a dead zone. If the temperature deviates less than 4°C from the set temperature, the system will not heat or cool. This so called dead zone of the thermostat prevents the system from turning on and off too often, saving energy.

This was helpful (1588) Read more

What is the best place to mount a thermostat? Verified

The best place for a thermostat is approximately 1,5 meter above the ground. Never place the thermostat nead a radiator or other heat emitting equipment or in direct sunlight. Choose a room that is used often. In most cases this is the living room.

This was helpful (990) Read more