Need a manual for your Emerson 1F83C-11PR Thermostat? Below you can view and download the PDF manual for free in English. This product currently has 2 frequently asked questions, 1 comment and has 1 vote with an average product rating of 100/100. If this is not the manual you want, please contact us.

Is your product defective and the manual offers no solution? Go to a Repair Café for free repair services.

Manual

Loading…

Electrical Rating:
Battery Power ..................................... mV to 30 VAC, NEC Class II, 50/60 Hz
Input-Hardwire .................................... 20 to 30 VAC, NEC Class II, 50/60 Hz
Terminal Load .......................................... 1.0 A per terminal, 1.5A maximum all terminals combined
Setpoint Range ........................................ 45° to 99° F (to 37° C)
Rated Dierentials: Fast Med Slow
Heat (@ 6°F/ Hr) .................................. 0.5°F 0.75°F 1.9°F
Cool (@ 6°F/ Hr) .................................. 0.9°F 1.2°F 1.7°F
Operating Ambient .................................. 32°F to +105°F (0° to +41°C)
Display Temperature Range ....................... 32°F to +99°F (0 to 37°C)
Operating Humidity ................................. 90% non-condensing max
Shipping Temperature Range ................... -20°F to + 150°F (-29° to +65°C)
Thermostat Dimensions ........................... 3-3/4” H x 6” W x 1-1/8” D
PART NO. 37-7478A-EN
1504
1F83C-11PR (Programmable)
Installation and Operating Instructions
80 Series Single Stage Thermostat
Battery Powered or Hardwired with Common
Thermostat Applications
Maximum
Stages
Heat/Cool
Conventional Gas, Oil, Electric (mV and
24V), Heat Only, Cool Only or Heat/
Cool Systems
1/1
Heat Pump (air source or geothermal)
with no Aux. Heat
1/1
Thermostat Installation
2-4
Wiring
2
Installer Menu
3-4
Using the Thermostat
5-7
Thermostat Overview
5
User Menu
6
Thermostat Operation
6
Thermostat Schedule
7
Troubleshooting
7-8
Homeowner Help Line
8
INDEX
SPECIFICATIONS
emersonthermostats.com
white-rodgers.com
MERCURY NOTICE: This product does not contain
mercury. However, this product may replace a product
that contains mercury. Mercury and products containing
mercury must not be discarded in household trash.
Refer to www.thermostat-recycle.org for information
on disposing of products containing mercury.
Optional Accessory: Wall Cover-Up Plate F61-2663, 6 3/4” W x 4 1/2” H
2
Terminal Designations Terminal Function
RC* Power for Cooling
RH* Power for Heating
O/B
Changeover Terminal-Energized in Heat (B) or Cool (O)
for Heat Pump or Damper Systems
Y** Cooling Relay
G Fan Relay
W** Heating Relay
C
Common wire for 24V (optional with batteries)
*When both RC and RH wires are present, cut RC/RH jumper (see next page).
**For heat pump systems, add a jumper wire to connect terminals Y and W
THERMOSTAT INSTALLATION
Leveling Thermostat
Leveling is for appearance only and
will not aect thermostat operation.
WIRING
Refer to equipment manufacturer’s instructions for specic system wiring information. After
wiring, see INSTALLER MENU for proper thermostat conguration. Wiring table shown are
for typical systems and describe the thermostat terminal functions.
WARNING
!
Do not use on circuits exceeding specied voltage.
Higher voltage will damage control and could
cause shock or re hazard.
Do not short out terminals on gas valve or primary
control to test. Short or incorrect wiring will burn
out thermostat and could cause personal injury
and/or property damage.
CAUTION
!
To prevent electrical shock and/or equipment
damage, disconnect electrical power to system,
at main fuse or circuit breaker box,until
installation is complete.
Precautions
Do not exceed the specication ratings.
All wiring must conform to local and national electrical codes and ordinances.
This control is a precision instrument, and should be handled carefully. Rough handing or
distorting components could cause the control to malfunction.
Download manual in English (PDF, 2.11 MB)
(Consider the environment and only print this manual if it is really necessary)

Loading…

Rating

Let us know what you think about the Emerson 1F83C-11PR Thermostat by leaving a product rating. Want to share your experiences with this product or ask a question? Please leave a comment at the bottom of the page.
Are you satisfied with the Emerson 1F83C-11PR Thermostat?
Yes No
100%
0%
1 vote

Join the conversation about this product

Here you can share what you think about the Emerson 1F83C-11PR Thermostat. If you have a question, first carefully read the manual. Requesting a manual can be done by using our contact form.

rick 18-07-2019
how to get off call for service

reply | This was helpful (0)

More about this manual

We understand that it’s nice to have a paper manual for your Emerson 1F83C-11PR Thermostat. You can always download the manual from our website and print it yourself. If you would like to have an original manual, we recommend you contact Emerson. They might be able to provide an original manual. Are you looking for the manual of your Emerson 1F83C-11PR Thermostat in a different language? Choose your preferred language on our homepage and search for the model number to see if we have it available.

Specifications

Brand Emerson
Model 1F83C-11PR
Category Thermostats
File type PDF
File size 2.11 MB

All manuals for Emerson Thermostats
More manuals of Thermostats

Frequently Asked Questions about Emerson 1F83C-11PR Thermostat

Our support team searches for useful product information and answers to frequently asked questions. If you find an inaccuracy in our frequently asked questions, please let us know by using our contact form.

What is the dead zone of a thermostat? Verified

Many modern thermostats have a dead zone. If the temperature deviates less than 4°C from the set temperature, the system will not heat or cool. This so called dead zone of the thermostat prevents the system from turning on and off too often, saving energy.

This was helpful (1588) Read more

What is the best place to mount a thermostat? Verified

The best place for a thermostat is approximately 1,5 meter above the ground. Never place the thermostat nead a radiator or other heat emitting equipment or in direct sunlight. Choose a room that is used often. In most cases this is the living room.

This was helpful (990) Read more
Manual Emerson 1F83C-11PR Thermostat

Related products

Related categories