7679433.01 (3-06/17) 4
User & Installer (en)
GENERAL PRECAUTIONS
This boiler has been designed to heat water to a temperature lower than boiling point at atmospheric pressure. It must be
connected to a central heating system and to a domestic hot water supply system according to its performance and power output.
Before having the boiler installed by a qualied service engineer, make sure the following operations are performed:
Make sure that the boiler is adjusted to use the type of gas delivered by the gas supply. To do this, check the markings on the
packaging and the data label on the appliance.
Make sure that the ue terminal draft is appropriate, that the terminal is not obstructed and that no exhaust gases from other
appliances are expelled through the same ue duct, unless the latter has been specially designed to collect exhaust gas from
more than one appliance, in compliance with current laws and regulations.
Make sure that, if the boiler is connected to existing ue ducts, these have been thoroughly cleaned as residual products of
combustion may detach from the walls during operation and obstruct the ow of fumes.
To ensure correct operation and maintain the warranty, observe the following precautions:
1. DHW circuit
1.1 If the water is harder than 20 °F (1 °F = 10 mg calcium carbonate per litre of water), install a polyphosphate dispenser or an
equivalent treatment system, compliant with current regulations.
1.2 Thoroughly ush the system after installation of the appliance and before use.
1.3 The materials used for the DHW circuit comply with Directive 98/83/EC.
2. Heating circuit
2.1 New system: Before installing the boiler, the system must be cleaned and ushed to eliminate residual thread-cutting swarf,
solder and any solvents, using suitable off-the-shelf non-acid and non-alkaline products that do not damage metal, plastic and
rubber parts. To protect the system from scale, use inhibitors such as SENTINEL X100 and FERNOX protector for heating circuits.
Use these products in strict compliance with the manufacturers' instructions.
2.2 Existing system: Before installing the boiler, drain the system and clean it to remove sludge and contaminants, using suitable
proprietary products. Recommended cleaning products are: SENTINEL X300 or X400 and FERNOX regenerator for heating
circuits. Use these products in strict compliance with the manufacturers' instructions. Remember that the presence of foreign
bodies in the heating system can adversely affect boiler operation (e.g. overheating and excessive noise of the heat exchanger).
Initial lighting of the boiler must be carried out by an authorised Service Engineer who must rst ensure that:
The rated data correspond to the supply (electricity, water and gas) data.
That the installation complies with current regulations.
The appliance is correctly connected to the power supply and earthed.
Failure to observe the above will render the warranty null and void. Prior to commissioning, remove the protective plastic
coating from the boiler. Do not use any tools or abrasive detergents to do this as you may damage the painted surfaces.
ENERGY-SAVING TIPS
Adjustment in the heating mode
Adjust the boiler ow temperature depending on the kind of system. For systems with radiators, set a maximum heating water ow
temperature of approximately 60°C, and increase this value if the required room temperature is not reached. For systems with
radiant oor panels, do not exceed the temperature indicated by the system designer. Use the External Sensor and/or Control
Panel to automatically adjust the ow temperature to atmospheric conditions or the indoor temperature. This ensures that no more
heat than that effectively necessary is produced. Adjust the room temperature without overheating the rooms. Every extra degree
centigrade means consuming approximately 6% more. Also room ambient temperature depending on how the rooms are used.
For example, the bedroom or the least used rooms can be heated to a lower temperature. Use the programmable timer and set the
night-time room temperature at approximately 5°C lower than that during the day. There is no appreciable saving to be achieved
by setting it any lower. Only in case of a prolonged absence, such as a holiday, should the temperature setpoint be lowered. Do
not cover radiators as this prevents the air from circulating correctly. Do not leave the windows partially open to ventilate the rooms
but open them completely for a short period.
Domestic hot water
Setting the domestic hot water at the required temperature without mixing it with cold water saves a lot of money. Additional
heating wastes energy and creates additional scale.
Download manual in English (PDF, 1.4 MB)
(Consider the environment and only print this manual if it is really necessary)

Loading…

Rating

Let us know what you think about the De Dietrich MPX 24 COMPACT Central Heating Boiler by leaving a product rating. Want to share your experiences with this product or ask a question? Please leave a comment at the bottom of the page.
Are you satisfied with the De Dietrich MPX 24 COMPACT Central Heating Boiler?
Yes No
Be the first to rate this product
0 votes

Join the conversation about this product

Here you can share what you think about the De Dietrich MPX 24 COMPACT Central Heating Boiler. If you have a question, first carefully read the manual. Requesting a manual can be done by using our contact form.

More about this manual

We understand that it’s nice to have a paper manual for your De Dietrich MPX 24 COMPACT Central Heating Boiler. You can always download the manual from our website and print it yourself. If you would like to have an original manual, we recommend you contact De Dietrich. They might be able to provide an original manual. Are you looking for the manual of your De Dietrich MPX 24 COMPACT Central Heating Boiler in a different language? Choose your preferred language on our homepage and search for the model number to see if we have it available.

Specifications

Brand De Dietrich
Model MPX 24 COMPACT
Category Central Heating Boilers
File type PDF
File size 1.4 MB

All manuals for De Dietrich Central Heating Boilers
More manuals of Central Heating Boilers

Frequently Asked Questions about De Dietrich MPX 24 COMPACT Central Heating Boiler

Our support team searches for useful product information and answers to frequently asked questions. If you find an inaccuracy in our frequently asked questions, please let us know by using our contact form.

What is the best pressure for my central heating boiler? Verified

The right pressure is between 1 and 1,5 bar. Never let the pressure rise above 2 bar.

This was helpful (595) Read more

The piping and radiators make noise. What is causing this? Verified

There is probably air in the heating system. It's best to purge the air from the system.

This was helpful (312) Read more