SAVE THESE INSTRUCTIONS!
Information on servicing
1. Checks to the area: Prior to beginning work on systems
containing ammable refrigerants, safety checks are
necessary to ensure that the risk of ignition is minimized.
For repair to the refrigerating system, the following
precautions shall be complied with prior to conducting
work on the system.
2. Work procedure: Work shall be undertaken under a
controlled procedure so as to minimize the risk of a
ammable gas or vapour being present while the work is
being performed.
3. General work area: All maintenance staff and others
working in the local area shall be instructed on the nature
of work being carried out. Work in conned spaces shall
be avoided. The area around the work space shall be
sectioned off. Ensure that the conditions within the work
area have been made safe by removing all ammable
material.
4. Checking for the presence of refrigerant:
The area shall be checked with an appropriate refrigerant
detector prior to and during work to ensure the technician
is aware of potentially ammable atmospheres. Ensure
that the leak detection equipment being used is suitable
for use with ammable refrigerants, i.e. non-sparking,
adequately sealed and intrinsically safe.
5. Presence of re extinguisher: If any hot work is to
be conducted on the refrigeration equipment or any
associated parts, appropriate re extinguishing equipment
shall be available to hand. Have a dry powder or C0
2
re
extinguisher adjacent to the work area.
6. No ignition sources: No person carrying out work in
relation to a refrigeration system which involves exposing
Important Safety Information
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
Transport of equipment containing ammable
refrigerants:
See transport regulations.
Marking of equipment using signs:
See local regulations.
Disposal of equipment using ammable
refrigerants:
See national regulations.
Storage of equipment / appliances:
The storage of equipment should be in accordance with the
manufacturer’s instructions.
Storage of packed (unsold) equipment:
Storage package protection should be constructed such that
the mechanical damage to the equipment inside the package
will not cause a leak of the refrigerant charge. The maximum
number of pieces of equipment permitted to be stored together
will be determined by local regulations.
any pipe work that contains or has contained ammable
refrigerant shall use any sources of ignition in such a
manner that it may lead to risk of re or explosion. All
possible ignition sources including cigarette smoking,
should be kept sufciently far away from the site of
installation, repairing, removing and disposal during
which ammable refrigerant can possibly be released to
the surrounding space. Prior to work taking place, the
area around the equipment is to be surveyed to make
sure there are no ammable hazards or ignition risks. No
smoking signs shall be displayed.
7. Ventilated area: Ensure that the area is in the open or that
it is adequately ventilated before breaking into the system
or conducting any hot work. A degree of ventilation
shall continue during the period that the work is carried
out. The ventilation should safely disperse any released
refrigerant and preferable expel it externally into the
atmosphere.
8. Checks to the refrigeration equipment: Where electrical
components are being changed, they shall be t for the
purpose and to the correct specication. At all times
the manufacturer’s maintenance and service guidelines
shall be followed. If in doubt consult the manufacturer’s
technical department for assistance. The following
checks shall be applied to installations using ammable
refrigerants:
The charge size is in accordance with the room size
within which the refrigerant containing parts are
installed.
The ventilation machinery and outlets are operating
adequately and are not obstructed.
If an indirect refrigerating circuit is being used, the
secondary circuit shall be checked for the presence of
refrigerant.
Marking to the equipment continues to be visible and
legible. Markings and signs that become illegible must
be corrected.
Refrigeration pipe or components are installed in a
position where they are unlikely to be exposed to any
substance which may corrode refrigerant containing
components, unless the components are constructed
of materials which are inherently resistant to being
corroded or are suitable protected against being
corroded.
9. Checks to electrical devices: Repair and maintenance to
electrical components shall include initial safety checks
and component inspection procedures. If a fault exists that
could compromise safety, then no electrical supply shall
be connected to the circuit until it is satisfactorily dealt
with. If the fault cannot be corrected immediately but it is
Download manual in English (PDF, 6.05 MB)
(Consider the environment and only print this manual if it is really necessary)

Loading…

Rating

Let us know what you think about the Danby DPA120CBIMBDB-6 Air Conditioner by leaving a product rating. Want to share your experiences with this product or ask a question? Please leave a comment at the bottom of the page.
Are you satisfied with the Danby DPA120CBIMBDB-6 Air Conditioner?
Yes No
Be the first to rate this product
0 votes

Join the conversation about this product

Here you can share what you think about the Danby DPA120CBIMBDB-6 Air Conditioner. If you have a question, first carefully read the manual. Requesting a manual can be done by using our contact form.

More about this manual

We understand that it’s nice to have a paper manual for your Danby DPA120CBIMBDB-6 Air Conditioner. You can always download the manual from our website and print it yourself. If you would like to have an original manual, we recommend you contact Danby. They might be able to provide an original manual. Are you looking for the manual of your Danby DPA120CBIMBDB-6 Air Conditioner in a different language? Choose your preferred language on our homepage and search for the model number to see if we have it available.

Specifications

Brand Danby
Model DPA120CBIMBDB-6
Category Air Conditioners
File type PDF
File size 6.05 MB

All manuals for Danby Air Conditioners
More manuals of Air Conditioners

Frequently Asked Questions about Danby DPA120CBIMBDB-6 Air Conditioner

Our support team searches for useful product information and answers to frequently asked questions. If you find an inaccuracy in our frequently asked questions, please let us know by using our contact form.

How often should I clean or replace the filters in my air conditioner? Verified

It's advisable to check the filters of your air conditioner 4 times a year. Dirty filters can be cleaned with the use of a vacuum cleaner or can be washed, depending on which type they are. During maintenance a professional should judge whether it is time to replace the filters.

This was helpful (2746) Read more

What does BTU stand for? Verified

BTU stands for British Thermal Unit. This is unit to indicate the capacity to cool.

This was helpful (986) Read more

Does every air conditioner also function as a dehumidifier? Verified

The cold air produced by an air conditioner often has a relatively low humidity. However, the effect is less than when using an actual dehumidifier. Some air conditioners do have a special feature to dehumidify the air.

This was helpful (752) Read more

What is R-410A? Verified

R-410A is a cooling agent that is used in appliances that cool up to 0°C, like refrigerators and air conditioners. It is the replacement of older cooling agents and does not damage the ozon layer.

This was helpful (517) Read more

Does an air conditioner have a negative influence on air quality? Verified

If the air conditioner has been properly maintained then it will have no influence on air quality. If for example a filter hasn't been replaced for a long time, or other maintenance has not been performed, than an air conditioner can produce dirty air.

This was helpful (372) Read more

What is the best place to mount the indoor unit of a split-type air conditioner? Verified

This depends on the space, but in general the following rules can be followed. Make sure that there is nothing obstructing the airflow. Make sure the location is accessible for maintenance. Mount the unit at least 2 meters from the ground.

This was helpful (370) Read more

Can I place my mobile air conditioner in a cabinet to get it out of sight? Verified

No, absolutely not. A mobile air conditioner needs space to allow airflow and air intake. In a small space the device can overheat.

This was helpful (369) Read more