Manual Clarke Spyder 3 Compressor

Need a manual for your Clarke Spyder 3 Compressor? Below you can view and download the PDF manual for free in English. This product currently has 0 frequently asked questions, 0 comments and has 0 votes. If this is not the manual you want, please contact us.

Is your product defective and the manual offers no solution? Go to a Repair Café for free repair services.

Manual

Loading…

If this is not the case, it is possible that the overload cutout has intervened. This is a safety
device to prevent the motor from overheating. The device will reset when the temperature
falls to a predetermined level. In this event, switch OFF the machine and wait for 5 -10
minutes, before pressing the RESET button , mounted on the top cover, and clearly marked,
and is shown in Fig.2..
Switch ON the machine and try again. If the motor fails to start, after several
attempts, consult your Clarke dealer.
Once the machine has started, turn ON the air supply to your air tool by opening the tap
(F), and turn the pressure regulator (G) clockwise so that your chosen setting, shown on
the label on top of the regulator knob, is in line with the inverted vee mark on the underside
side of the casting. Note that the pressure gauge registers the pressure in the receiver
only.
IMPORTANT:
As no outlet pressure gauge is fitted to this model, the marks on the
Pressure Regulator provide an indication ONLY of the output pressure. If
you are using pressure sensitive tools or equipment, you should insert a
pressure gauge in the airline.
Check to ensure that there are no air leaks at any of the couplings or in other
parts of the system before operating the spray gun or air tool in the normal way.
When the compressor reaches its maximum working pressure, the motor will
automatically cut out, and will restart when the pressure has fallen by
approximately 20 psi. This automatic STOP/START process will continue, as
necessary, to maintain pressure in the receiver.
When you have finished the job in hand ALWAYS switch OFF at the ON/OFF switch,
NOT the mains supply, and release any pressure remaining in the system by opening
the drain valve until all air is expelled.
ALWAYS operate the air tool to further ensure that there is no pressure in the system
BEFORE disconnecting the tool. Finally, reset the pressure regulator to zero by turning
the regulator knob fully anticlockwise.
- 7 -
ROUTINE MAINTENANCE
IMPORTANT: Before carrying out any maintenance, always disconnect the machine
from the mains supply, drain the air receiver and, if necessary, allow the machine
to cool down before starting work.
Daily
Before use, always open the drain valve and tip the machine on to its end. Hold in that
position until all condensate has drained off. Do not rest machine on the drain valve.
Monthly
It is important to keep the compressor clean, with the help of a small soft brush and
vacuum cleaner. In particular, the air intake filter should be inspected at least
MONTHLY, and more often in dusty conditions, so that it is always kept free of any dirt
- 14 -
1 Drain cock 3/8 1 FN022020000
2 Vibration damper support 1 FN020201000
3 Screw M5x15 2 FN014013042
4 Tank 6 lt. 1 FN126HU0011V
5 Delivery tube 1 FN129HU0011
6 Rilsan tube 1 FN046001000
7 Seal 1 n/a
8 Spring 1 n/a
9 Gasket 1 n/a
10 Non-Return Valve 1 FN347060000
11 Vibration damper support 2 FN020202000
12 Nipple 1/4" 2 FN011017000
13 Pressure switch 1 FN321028000
14 Pressure gauge Ø40 1 FN330006000
15 Safety valve 1 FN347022000
16 Power cable with BSI plug 1 FN101GA0200
17 Pressure reducer with line cock 1 FN319044000
18 OL185 Compressor complete 1 FN516HP01604
B. SPYDER 7
No. Description Qty Part No.
n/a - not available
1 Drain cock 3/8 1 FN022020000
2 Vibration damper support 1 FN020201000
3 Screw M5x15 2 FN014013042
4 Tank 2 lt. 1 FN126HU0010V
5 Delivery tube 1 FN129HU0010
6 Rilsan tube 1 FN046001000
7 Safety valve 1 FN347022000
8 Elbow R1/4" 1 FN011002000
9 Pressure gauge Ø40 1 FN330006000
10 Nipple 1/4" 1 FN011017000
11 Pressure reducer with line cock 1 FN319044000
12 Pressure switch 1 FN321028000
13 Power cable with BSI plug 1 FN101GA0200
14 Straight adapter 1 FN199626000
15 Seal 1 n/a
16 Spring 1 n/a
17 Gasket 1 n/a
18 Non-Return Valve 1 FN347060000
19 Vibration damper support 1 FN020202000
20 OL185 Compressor complete 1 FN516HP01604
PARTS LIST - RECEIVER AND COMPONENTS
A. SPYDER 3
No. Description Qty Part No.
Download manual in English (PDF, 2.74 MB)
(Consider the environment and only print this manual if it is really necessary)

Loading…

Rating

Let us know what you think about the Clarke Spyder 3 Compressor by leaving a product rating. Want to share your experiences with this product or ask a question? Please leave a comment at the bottom of the page.
Are you satisfied with the Clarke Spyder 3 Compressor?
Yes No
Be the first to rate this product
0 votes

Join the conversation about this product

Here you can share what you think about the Clarke Spyder 3 Compressor. If you have a question, first carefully read the manual. Requesting a manual can be done by using our contact form.

More about this manual

We understand that it’s nice to have a paper manual for your Clarke Spyder 3 Compressor. You can always download the manual from our website and print it yourself. If you would like to have an original manual, we recommend you contact Clarke. They might be able to provide an original manual. Are you looking for the manual of your Clarke Spyder 3 Compressor in a different language? Choose your preferred language on our homepage and search for the model number to see if we have it available.

Specifications

Brand Clarke
Model Spyder 3
Category Compressors
File type PDF
File size 2.74 MB

All manuals for Clarke Compressors
More manuals of Compressors

Manual Clarke Spyder 3 Compressor

Related products

Related categories