Display BP4900/BP5900
* For BP5900 only
Note: On BP5900, the backlight goes on when the unit is turned on, buttons are pressed, or
when results are being displayed. It turns itself o after 10 seconds if no buttons are pressed.
Heart rate symbol
Memory record
Measuring
error display
Low battery indicator
Month
Minute
Date
Hour
Average symbol
Morning average record*
Evening average record*
Irregular heart beat
symbol*
Morning
hypertension
symbol*
Fig. 9
Setting month, date and time
a. Press mode (5) button (“month” starts ashing)
Press set
(4) button to set the correct month (1,2,3,…12)
b. Press mode
(5) button (“date” start ashing)
Press set
(4) button to set the correct date (1,2,3,…31)
c. Press mode
(5) button (“hour” starts ashing)
Press set
(4) button to set the correct hour (1,2,3,…12)
d. Press mode
(5) button (“minute starts ashing)
Press set
(4) button to set the correct minute (0,1,2,3,…59)
e. Press mode
(5) button again to lock in time settings. Digits will stop ashing.
Taking a measurement
Wrap the cu around the arm (see “applying the arm cu section above).
1. Sit upright on the chair to have a correct posture.
2. Press the “start/stop
(1) button, all elements of the display indicate
“888” during the rst 3 seconds. The measuring blood pressure symbol will
then ash on the display and the air pressure will automatically pump up
to certain pressure level and start measurement. (Fig.9 BP4900/BP5900)
Do not move or talk in the midst of taking blood pressure measurement.
3. After the air pressure has increased, it will slowly decrease. When the
pulse is detected, the heart rate
symbol will start ashing.
After taking blood pressure measurement, the product will turn o
automatically after 1 minute.
Memory function
Your blood pressure monitor can store the latest readings of
48 measurements for BP4900, or 99 measurements for BP5900.
Storing measurement data
After each blood pressure measurement, the Systolic pressure, diastolic pressure, pulse rate
and the time & date of specic day will be automatically stored. Memory #01 is always the
most recent one. Once the memory is full, the oldest values will be overwritten.
Recalling stored readings
Press “memory
M
(2) button, M:00 will appear on the display if there is no
data stored in the memory. If there is data stored in the memory, the latest
recorded set of measurement which is the systolic pressure, diastolic
pressure, pulse rate, and the recording time and date and M:01 will appear
on the display for 1 minute.
Press the “memory
M
(2) button again to read the next line of stored data.
The data called up on the display with 2-digit memory number (ex. M:02).
7-day average function
Full day average
• Press the “average (3) button once, “full day average” result will show
on LCD.
• Make sure the date / time is correct when taking measurement, so you
may get the correct 7-day average result.
If there is no data in memory within past 7 days,
will show on LCD.
Download manual in English (PDF, 4.72 MB)
(Consider the environment and only print this manual if it is really necessary)

Loading…

Rating

Let us know what you think about the Braun BP4900 ExactFit 3 Blood Pressure Monitor by leaving a product rating. Want to share your experiences with this product or ask a question? Please leave a comment at the bottom of the page.
Are you satisfied with the Braun BP4900 ExactFit 3 Blood Pressure Monitor?
Yes No
Be the first to rate this product
0 votes

Join the conversation about this product

Here you can share what you think about the Braun BP4900 ExactFit 3 Blood Pressure Monitor. If you have a question, first carefully read the manual. Requesting a manual can be done by using our contact form.

reham amer 30-06-2025
Error malfunction appeared on the screen and the device does not work

reply | This was helpful (0) (Translated by Google)
Serdar Karagöz 28-12-2025
What is the price

reply | This was helpful (0) (Translated by Google)

More about this manual

We understand that it’s nice to have a paper manual for your Braun BP4900 ExactFit 3 Blood Pressure Monitor. You can always download the manual from our website and print it yourself. If you would like to have an original manual, we recommend you contact Braun. They might be able to provide an original manual. Are you looking for the manual of your Braun BP4900 ExactFit 3 Blood Pressure Monitor in a different language? Choose your preferred language on our homepage and search for the model number to see if we have it available.

Specifications

Brand Braun
Model BP4900 ExactFit 3
Category Blood Pressure Monitors
File type PDF
File size 4.72 MB

All manuals for Braun Blood Pressure Monitors
More manuals of Blood Pressure Monitors

Frequently Asked Questions about Braun BP4900 ExactFit 3 Blood Pressure Monitor

Our support team searches for useful product information and answers to frequently asked questions. If you find an inaccuracy in our frequently asked questions, please let us know by using our contact form.

I just measured my blood pressure with a blood pressure monitor, but what is considered a 'normal' blood pressure? Verified

In general a systolic pressure of 120 and a diastolic pressure of 80 is considered normal or healthy. People aged 60 and over can have a slightly higher blood pressure.

This was helpful (1294) Read more

What are systolic and diastolic blood pressure? Verified

When measuring blood pressure two values are displayed, systolic and diastolic pressure. Systolic pressure is the pressure on the veins when the heart contracts and diastolic pressure is the pressure on the veins then the heart relaxes.

This was helpful (548) Read more

Is there any BPA in the plastics used in Braun products? Verified

Braun indicates that in all products there is no BPA used in parts that may come in contact with food.

This was helpful (319) Read more
Manual Braun BP4900 ExactFit 3 Blood Pressure Monitor

Related products

Related categories

×
Download