1. RECOMMENDATIONS AND
SUGGESTIONS
The Instructions for Use apply to several ver-
sions of this appliance. Accordingly, you may
nd descriptions of individual features that do
not apply to your specic appliance.
The manufacturer will not be held liable for any
damages resulting from incorrect or improper
installation.
The minimum safety distance between the
cooker top and the extractor hood is 650 mm
(some models can be installed at a lower
height, please refer to the paragraphs on work-
ing dimensions and installation).
Check that the mains voltage corresponds to
that indicated on the rating plate xed to the
inside of the hood.
For Class I appliances, check that the domestic
power supply guarantees adequate earthing.
Connect the extractor to the exhaust ue
through a pipe of minimum diameter 120
mm. The route of the ue must be as short as
possible.
Do not connect the extractor hood to exhaust
ducts carrying combustion fumes (boilers,
replaces, etc.).
If the extractor is used in conjunction with
non-electrical appliances (e.g. gas burning ap-
pliances), a sufcient degree of aeration must
be guaranteed in the room in order to prevent
the backow of exhaust gas. The kitchen must
have an opening communicating directly with
the open air in order to guarantee the entry of
clean air. When the cooker hood is used in con-
junction with appliances supplied with energy
other than electric, the negative pressure in the
room must not exceed 0,04 mbar to prevent
fumes being drawn back into the room by the
cooker hood.
In the event of damage to the power cable, it
must be replaced by the manufacturer or by
the technical service department, in order to
prevent any risks.
Connect the hood to the mains through a
two-pole switch having a contact gap of at least
3 mm.
If the instructions for installation for the gas hob
specify a greater distance specied above, this
has to be taken into account. Regulations con-
cerning the discharge of air have to be fullled.
2. USE
The extractor hood has been designed ex-
clusively for domestic use to eliminate kitchen
smells.
Never use the hood for purposes other than for
which it has been designed.
Never leave high naked ames under the hood
when it is in operation.
Adjust the ame intensity to direct it onto the
bottom of the pan only, making sure that it does
not engulf the sides.
Deep fat fryers must be continuously monitored
during use: overheated oil can burst into
ames.
Do not ambè under the range hood; risk of
re.
This appliance is not intended for use by per-
sons (including children) with reduced physical,
sensory or mental capabilities, or lack of experi-
ence and knowledge, unless they have been
given supervision or instruction concerning use
of the appliance by a person responsible for
their safety.
Children should be supervised to ensure that
they do not play with the appliance.
“ CAUTION: Accessible parts may become hot
when used with cooking ap-pliances”.
3. MAINTENANCE
Switch off or unplug the appliance from the
mains supply before carrying out any mainte-
nance work.
Clean and/or replace the Filters after the speci-
ed time period (Fire hazard).
- Activated charcoal lter W These lters are
not washable and cannot be regenerated,
and must be replaced approximately every 4
months of operation, or more frequently with
heavy usage.
- Grease lters Z The lters must be cleaned
every 2 months of operation, or more fre-
quently for particularly heavy usage, and can
be washed in a dishwasher.
- Control lights, if present.
Clean the hood using a damp cloth and a
neutral liquid detergent.
W
Z
Download manual in English (PDF, 15.24 MB)
(Consider the environment and only print this manual if it is really necessary)

Loading…

Rating

Let us know what you think about the AEG X92384MI01 Cooker Hood by leaving a product rating. Want to share your experiences with this product or ask a question? Please leave a comment at the bottom of the page.
Are you satisfied with the AEG X92384MI01 Cooker Hood?
Yes No
Be the first to rate this product
0 votes

Join the conversation about this product

Here you can share what you think about the AEG X92384MI01 Cooker Hood. If you have a question, first carefully read the manual. Requesting a manual can be done by using our contact form.

More about this manual

We understand that it’s nice to have a paper manual for your AEG X92384MI01 Cooker Hood. You can always download the manual from our website and print it yourself. If you would like to have an original manual, we recommend you contact AEG. They might be able to provide an original manual. Are you looking for the manual of your AEG X92384MI01 Cooker Hood in a different language? Choose your preferred language on our homepage and search for the model number to see if we have it available.

Specifications

Brand AEG
Model X92384MI01
Category Cooker Hoods
File type PDF
File size 15.24 MB

All manuals for AEG Cooker Hoods
More manuals of Cooker Hoods

Frequently Asked Questions about AEG X92384MI01 Cooker Hood

Our support team searches for useful product information and answers to frequently asked questions. If you find an inaccuracy in our frequently asked questions, please let us know by using our contact form.

How much distance should there be between my cooker hood and my hob? Verified

This can very a bit depending on the brand, but in general a cooker hood should be placed at least 65 centimeter above a gas hob and at least 50 centimeter above an electric or induction hob. This is to improve fire safety

This was helpful (1217) Read more

Do I need a cooker hood with or without motor? Verified

Cooker Hoods with motor are meant for when the air is moved directly outside. A cooker hood without motor is meant for when there is a central ventilation system. Never connect a cooker hood with motor to a central ventilation system!

This was helpful (640) Read more

How can I clean the filters in my AEG cooker hood? Verified

The filters in all AEG cooker hoods can be washed by hand. Some models have a filter that can be washed in a dishwasher. This can be found in the user manual. Be sure the filter is dry when it is placed back into the cooker hood.

This was helpful (209) Read more