PACKAGE CONTENTS
Water Tank
Nozzle
Water Tank Cap
UV+ SYSTEM
User
Manual
User Manual
L200 / L201Model Name:
Use & Care
Guide:
Ultrasonic Humidifier
•
The Product warrranty is printed on the back of this guide.
•
This Product is manufactured for use only in USA / CA.
•
This Product is suitable for 120 V only.
Demineralization
Capsules (2)
Pre-Soaked
Aroma Pads (2)
Unit
Handle
Control
Display
Mist Tube
Aroma Pad
Tray
Power Cord
LightCel™ Cover
Guide Bracket
Silencer
Water Valve
Air Outlet
WHERE TO USE
MODEL PART DIAGRAM
12~18 in
12~18 in
•
Position the humidifier at least 12 in / 30 cm away from walls and
appliances to prevent them from getting wet.
•
Place the humidifier on a table or desk. Do not place it directly on the
floor or carpet.
•
DO NOT place the unit against walls or objects or in areas with poor
air circulation. Doing so may result in improper readings produced
by the built-in humidity sensor.
•
If used in a closed (sealed) room without proper ventilation and no
heat exchange with outside air, water collection can occur when
the humidified air touches the cold surface. In such cases, it is
recommended to use in a lower mist level.
01. Power Button
•
Plug unit into a 120-volt AC electrical outlet.
Press the power button to turn unit on.
•
If there is no water inside, the power button does
not work.
02. Warm Mist Setting
•
To change the mist temperature from cool to warm
mist, press the warm mist button.
•
Warm humidification mode is always OFF and is
heated only when the user operates the button.
03. Night Mood Light
•
Press the Night Mood Light Display Button once
to turn on the Night Mood Light. The light at the
bottom of the water tank will turn on, illuminating
the tank.
•
The brightness of the light should be switched
OFF > 100% > 50% > 20% > OFF > Display light Off.
04. Programable Auto-Off Timer
•
Keep pressing the programmable timer button until
the desired timer setting is lit on the display.
•
The programable timer button will cycle through the
following settings: 0 hours, 2 hours, 4 hours, 8 hours,
and 12 hours. To cancel the timer at any time, press
the timer button until 0 hours is shown on the display.
CONTROL PANEL
Capacity
•
2 Gallons - 7.5 Liters
LightCel™ Technology
•
UV-C LED antibacterial.
Runtime: Max 120 Hours
•
Based on the natural humidity level in your home, the
temperature of water you use, and the mist level setting
you choose, you may experience longer or shorter
runtimes.
Adjustable Mist Level
•
Mist adjusts from the lowest output to highest ouput.
•
The corresponding mist level will be lit on the LED
indicator.
•
Each press will increase by one. Once you reach level 5,
it will repeat at level 1.
360° Rotating Mist Nozzle
•
Rotate the mist nozzle to adjust the mist output direction.
Whisper-Quiet Operation
•
Quiet operation allows you to sleep easily in a
comfortable and quiet environment.
Night Mood Light
•
A useful light feature is included with the option of an
independent Night Mood Light and control light display.
Auto Shut Off Protection
•
When the tank is empty, the unit will shut off
automatically.
Demineralization Capsules
•
The Winix demineralization capsule will help reduce the
potential for white dust; a deposit of minerals left behind
from using hard water in your humidifier.
Installation Instructions:
1.
Open the Water Tank Cap and fill the tank with water up
to 'max'.
2.
Remove demineralization capsule from the package.
3.
Put the capsule into the tank and wait for 10 minutes.
4.
Demineralization capsule cannot be reused. If you
want to place an order of our demineralization capsule,
please visit www.winixamerica.com.
Pre-Soaked Aroma Pads & Aroma Pad Tray
•
Includes 2 Pre-Soaked Aroma Pads. Use your favorite
essential oil to deliver aroma into the air.
Installation Instructions:
1.
Turn off the humidifier.
2.
Push the Oil Tray at the back of the base and pull it out.
3.
Tear the pouch at the notch to expose pad, insert pad
into the Aroma Tray.
4.
Enjoy the refreshing aroma! The scent lasts up to 48
hours (2 full days).
CAUTION
1) Contact with exposed pad may cause eye irritation. In
case of contact with eyes, flush with water immediately.
If eye irritation persists, consult with a doctor.
2) If you want to remove the aroma pad or if the humidifier
has not been operating for a long time, clean and dry
the tray and put it back in place.
3) Never put the aroma pad in the water tank.
MAINTENANCE AND CLEANING
ULTRASONIC WARM & COOL MIST HUMIDIFICATION
Read all instructions before installation and use
•
Always place humidifier on a firm, flat surface.
A waterproof mat or pad is recommended for under
the humidifier. A finished floor may be damaged by
water or moisture exposure.
•
Do not reach for a unit that has fallen into water.
Unplug it immediately.
•
Always unplug the unit from the electrical outlet
immediately after using and before cleaning.
•
Do not place or store the unit where it can fall or be
pulled into a tub or sink.
Wash the nozzle, cover separately, and let tank dry in
the shade
•
Clean tank at least once or twice a week using
clean water.
•
Naturally occurring stains inside the tank can be
cleaned using a soft cloth.
•
Do not use chemicals such as bleach, abrasive, etc.
to clean.
Cleaning the ultrasonic transducer
•
Clean the ultrasonic module of
the humidifier at least once or
twice a week.
•
Tilt it in the direction of the air
hinge when disposing of
the water in the main body.
•
Do not allow water into this
opening (air outlet).
•
Never touch the transducer/ultrasonic membrane
with your fingers; the natural oil and cosmetics
in the skin can damage the surface.
•
Never clean the ultrasonic membrane by scraping
with a hard object. Scratching the surface of the
vibrator with a sharp object may cause the Mist
Output to weaken or cause failure.
•
Never submerge the base in water or any other liquid.
•
In general, if the user touches the transducer/
ultrasonic membrane with their fingers, the natural
oil and cosmetics on the skin can damage the
surface, resulting in irregular mist output.
In order to have the unit run properly after this
occurs, you need to:
1.
Wash the water tank and the base 2 ~ 3 times and
then restart the unit. In case the unit is not washed,
the unit will operate normally after running for
30 min ~ 1 hour on continuous mode.
2.
If the water is not enough, the mist may not be
generated properly. (This may be a defect in the air
hinge or water valve).
There should be at least
30 mm of water in the base after removing the
water tanks.
Guide bracket silencer
•
Press down on the hook and lift it up.
•
It is best to wash off with clean, running water.
•
Dry and refit.
Deep cleaning (with vinegar)
•
Before and after storing the humidifier for a long
period of time, be sure to dry the Mist Output
completely and wipe clean.
•
Clean the tank, reservoir, tank cap, and transducer/
ultrasonic membrane with a 10:1 ratio mixture of
water and white vinegar.
•
Fill the tank with diluted vinegar water to the
maximum level.
•
Put roughly 400 mL of mixed water into the main
body.
•
Fill the water tank and main body with water and
leave for 30 to 60 minutes.
•
Pour out mixed water and rinse with clean tap water
2 ~ 3 times.
•
Dry the parts in a well-shaded place.
•
Please reassemble the dried product.
INITIAL OPERATION
CAUTION: Before filling the tank with water, turn the power off and unplug the unit from the outlet.
※
NOTE: Always use 2 hands to carry the water tank.
1.
Remove the water tank cap to fill the tank.
The convenient top-fill tank can be filled with a
pitcher or at the faucet.
2.
Lift the water tank from the base by using the
handle located on the back of the unit.
3.
Fill the tank with clean, room temperture water
until the water level reaches the MAX fill mark.
4.
The water tank holds a maximum of 7.5 Liters.
Water level is visible from outside.
5.
Plug in to outlet and turn appliance on. Always add
water to unit before connecting to power to avoid
burning the unit.
6.
Always operate the humidifier with the tank
cover seated on the tank. Refill the water tank to
continue using the humidifier.
Replacing Aroma Pads
•
Pre-Soaked Aroma Pads last 48 hours each.
•
There are two Pre-Soaked Aroma Pad scents:
1 lavender and 1 eucalyptus.
Please don't put any other materials other than
Aroma Pads.
05. Programmable Humidistat
•
The default humidistat setting is CO (continuous).
The programmable humidistat can be set in 5%
increments, from 40% to 60% humidity.
•
Manual humidity is set in 40% > 45% > 50% > 55% >
60% > CO order.
※
NOTE: When the set humidity level is reached, the
humidifier will cycle off until the humidity in the
room drops 5% below the set humidity level, then
will cycle on until the set humidity level is reached
again.
06. Adjustable Mist Level
•
Mist adjusts from the lowest output to the highest
output.
•
The corresponding mist level will be lit on the
display. Each press will increase by one.
•
Once you reach level 5, it will repeat at level 1.
07. LightCel™ (UV+)
•
Displays the operation status of the UV-C LED that
sterilizes the flow path of the reservoir.
•
Power of the product is activated and turned off
when no water is detected.
※
NOTE: LightCel™ Technology Removes bacteria*
present in water, Ensuring a safe and sanitized mist
for you and your family.
(*Based on independent laboratory test conducted
on Escherichia coil, Staphylococcus aureus,
Salmonella typhimurium, Klebsiella pneumoniae)
08. Warm Light
•
If you select warm humidification, it turns on.
09. Timer/Display Light
•
When a time reservation is set, it turns on and
displays the time on the display.
10. Empty Tank Alarm
•
If there is not enough water, the unit will stop and
the red LED indicator will continue to blink at the
same time.
11. Mist Level Indicator
•
Displays the humidity level and goes up one step
each time the humidity level button is pressed.
07
08 11
09 10
01
02
03
04
05
06
LUNA2.0_EN.indd 1
2020-10-22 5:54:09
Join the conversation about this product
Here you can share what you think about the Winix L200 Humidifier. If you have a question, first carefully read the manual. Requesting a manual can be done by using our contact form.