WIRING
If the heating equipment manufacturer has made provisions
or recommendations for the location of this control, then follow
those instructions. If not, the following suggestions should be
observed.
1. The control should be mounted in the wall, approximately
five feet from the floor, as near as possible to the center of
the controlled area.
2. It should be mounted on a partitioning wall, not on an outside
wall.
INSTALLATION
All wiring must conform to local and national electrical codes and ordinances.
The thermostat may be mounted in any standard 2" x 4" elec-
trical outlet box. For ease of installation use a deep type box.
USE WITH COPPER CONDUCTORS ONLY. Use approved
wire connectors for 12 AWG only.
1. Disconnect electrical power to the system at main fuse or circuit box.
2. Make electrical connection to thermostat leads with wire nuts or
other local code approved devices. All connections must be tight.
3. Push the lead wires into the outlet box.
4. Remove thermostat cover. Push thermostat case into junction box
and secure with screws provided.
Take care not to push or damage the bimetal sensing element
during installation.
5. Install thermostat cover and turn knob to desired setting.
CAUTION
!
L1
RED
L2
BLK
RED
BLK
LIMIT
CONTROL
HEATER
POWER
IN
LO
AD
LOAD
3. It should be mounted as far as possible from undesirable
sources of heat and cold such as:
a. Windows and doors
b. Direct rays from sun
c. Hot water or cold water pipes
d. Adjoining outside walls
240/277 VAC Wiring Diagram
L1
RED
L2
BLK
RED
BLK
LIMIT
CONTROL
HEATER
POWER IN
120 VAC ONLY
LO
AD
LOAD
HOT
COMMON
120 VAC Wiring Diagram
POWER IN
TO LOAD
SWITCH OPENS
IN "OFF" POSITION
HOT (L1)
COMMON (L2)
BLK
RED
RED
BLK
Temperature Limiting Pins
Temperature Limiting Option is for applications where the temperature
setting of the control is to be set and "protected" from unauthorized
adjustment. To limit the temperature range, follow the directions below:
1. Remove cover from thermostat.
2. On inside of cover, firmly press small tapered end of a pin into the
approximate maximum and minimum temperature positions.
3. After pressing pins into place on inside of cover, rotate temperature
knob to be sure the knob is between the pins.
4. Replace cover on thermostat. Check that knob rotation is limited in
travel as set by the pins. If rotation of knob is outside of limits, check
that the pins are installed properly.
5. Install supplied screws at top and bottom of thermostat to secure
cover.
Pins are shown installed at
60 and 65˚. The temperature
setting range is limited
between these two
temperatures.
The third pin is supplied as a
spare in case of accidental
loss.
Inside of cover
Schematic Diagram
www.white-rodgers.com
White-Rodgers is a division
of Emerson Electric Co.
Download manual in English (PDF, 0.57 MB)
(Consider the environment and only print this manual if it is really necessary)

Loading…

Rating

Let us know what you think about the White Rodgers B50 Thermostat by leaving a product rating. Want to share your experiences with this product or ask a question? Please leave a comment at the bottom of the page.
Are you satisfied with the White Rodgers B50 Thermostat?
Yes No
Be the first to rate this product
0 votes

Join the conversation about this product

Here you can share what you think about the White Rodgers B50 Thermostat. If you have a question, first carefully read the manual. Requesting a manual can be done by using our contact form.

More about this manual

We understand that it’s nice to have a paper manual for your White Rodgers B50 Thermostat. You can always download the manual from our website and print it yourself. If you would like to have an original manual, we recommend you contact White Rodgers. They might be able to provide an original manual. Are you looking for the manual of your White Rodgers B50 Thermostat in a different language? Choose your preferred language on our homepage and search for the model number to see if we have it available.

Specifications

Brand White Rodgers
Model B50
Category Thermostats
File type PDF
File size 0.57 MB

All manuals for White Rodgers Thermostats
More manuals of Thermostats

Frequently Asked Questions about White Rodgers B50 Thermostat

Our support team searches for useful product information and answers to frequently asked questions. If you find an inaccuracy in our frequently asked questions, please let us know by using our contact form.

What is the dead zone of a thermostat? Verified

Many modern thermostats have a dead zone. If the temperature deviates less than 4°C from the set temperature, the system will not heat or cool. This so called dead zone of the thermostat prevents the system from turning on and off too often, saving energy.

This was helpful (1588) Read more

What is the best place to mount a thermostat? Verified

The best place for a thermostat is approximately 1,5 meter above the ground. Never place the thermostat nead a radiator or other heat emitting equipment or in direct sunlight. Choose a room that is used often. In most cases this is the living room.

This was helpful (992) Read more
Manual White Rodgers B50 Thermostat

Related products

Related categories