Makeup Air
Local building codes may require the use of makeup air systems
when using ventilation systems greater than specified CFM of
air movement. The specified CFM varies from locale to locale.
Consult your HVAC professional for specific requirements in
your area.
Venting Methods
This island hood is factory set for venting through the roof.
A 6" (15.2 cm) round vent system is needed for installation
(not included). The hood exhaust opening is 6" (15.2 cm) round.
NOTE: Flexible vent is not recommended. Flexible vent
creates back pressure and air turbulence that greatly
reduce performance.
Vent system can terminate either through the roof or wall.
To vent through a wall, a 90° elbow is needed.
For Non-Vented (Recirculating) Installations
If it is not possible to vent cooking fumes and vapors to the
outside, the hood can be used in the non-vented (recirculating)
version, fitting a charcoal filter and the deflector. Fumes and
vapors are recycled through the top grille. To order, see the
“Assistance or Service” section.
NOTE: If codes permits, wall venting can be an option
for 2-story homes.
Calculating Vent System Length
To calculate the length of the system you need, add the
equivalent feet (meters) for each vent piece used in the system.
Vent Piece 6" (15.2 cm) Round
45° elbow 2.5 ft (0.8 m)
90° elbow 5 ft (1.5 m)
Maximum equivalent vent length is 35 ft (10.7 m).
Example Vent System
The following example falls within the maximum
recommended vent length of 35 ft (10.7 m).
1 - 90° elbow = 5 ft (1.5 m)
1 - wall cap = 0 ft (0 m)
8 ft (2.4 m) straight = 8 ft (2.4 m)
Length of system = 13 ft (3.9 m)
Electrical Requirements
Observe all governing codes and ordinances.
Ensure that the electrical installation is adequate and in
conformance with National Electrical Code, ANSI/NFPA
70 (latest edition), or CSA Standards C22.1-94, Canadian
Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition)
and all local codes and ordinances.
If codes permit and a separate ground wire is used,
it is recommended that a qualified electrician determine
that the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
A 120 volt, 60 Hz., AC only, 15 amp, fused electrical
circuit is required.
If the house has aluminum wiring, follow the
procedure below:
Connect the aluminum wiring using special connectors
and/or tools designed and UL listed for joining copper to
aluminum.
Follow the electrical connector manufacturer’s recommended
procedure. Aluminum/copper connection must conform with
local codes and industry accepted wiring practices.
Wire sizes and connections must conform with the rating of
the appliance as specified on the model/serial/rating plate.
The model/serial/rating plate is located behind the left filter
on the rear wall of the range hood.
Wire sizes must conform to the requirements of the National
Electrical Code, ANSI/NFPA 70 (latest edition), or CSA
Standards C22. 1-94, Canadian Electrical Code, Part 1
and C22.2 No. 0-M91 (latest edition) and all local codes
and ordinances.
Non-Vented (Recirculating)
Roof Venting
B
A
B
A
A. Deflector
B. 6" (15.2 cm) round vent
A. Roof cap
B. 6" (15.2 cm) round vent
90 elbo
w
6 ft (1.8 m)
2 ft
(0.6 m)
Wall cap
Download manual in English (PDF, 6.88 MB)
(Consider the environment and only print this manual if it is really necessary)

Loading…

Rating

Let us know what you think about the Whirlpool WVI75UC6DS Cooker Hood by leaving a product rating. Want to share your experiences with this product or ask a question? Please leave a comment at the bottom of the page.
Are you satisfied with the Whirlpool WVI75UC6DS Cooker Hood?
Yes No
Be the first to rate this product
0 votes

Join the conversation about this product

Here you can share what you think about the Whirlpool WVI75UC6DS Cooker Hood. If you have a question, first carefully read the manual. Requesting a manual can be done by using our contact form.

More about this manual

We understand that it’s nice to have a paper manual for your Whirlpool WVI75UC6DS Cooker Hood. You can always download the manual from our website and print it yourself. If you would like to have an original manual, we recommend you contact Whirlpool. They might be able to provide an original manual. Are you looking for the manual of your Whirlpool WVI75UC6DS Cooker Hood in a different language? Choose your preferred language on our homepage and search for the model number to see if we have it available.

Specifications

Brand Whirlpool
Model WVI75UC6DS
Category Cooker Hoods
File type PDF
File size 6.88 MB

All manuals for Whirlpool Cooker Hoods
More manuals of Cooker Hoods

Frequently Asked Questions about Whirlpool WVI75UC6DS Cooker Hood

Our support team searches for useful product information and answers to frequently asked questions. If you find an inaccuracy in our frequently asked questions, please let us know by using our contact form.

How much distance should there be between my cooker hood and my hob? Verified

This can very a bit depending on the brand, but in general a cooker hood should be placed at least 65 centimeter above a gas hob and at least 50 centimeter above an electric or induction hob. This is to improve fire safety

This was helpful (1349) Read more

What does '6th Sense' mean? Verified

Whirlpool appliances that are equipped with 6th Sense technology have sensors that ensure optimal operation of the machine. For example in dryers, these sensors measure the moisture left in the wash and stops the machine when everything is completely dry.

This was helpful (909) Read more

Do I need a cooker hood with or without motor? Verified

Cooker Hoods with motor are meant for when the air is moved directly outside. A cooker hood without motor is meant for when there is a central ventilation system. Never connect a cooker hood with motor to a central ventilation system!