Manual Vemer Klima 3V Thermostat

Need a manual for your Vemer Klima 3V Thermostat? Below you can view and download the PDF manual for free in English. This product currently has 2 frequently asked questions, 0 comments and has 0 votes. If this is not the manual you want, please contact us.

Is your product defective and the manual offers no solution? Go to a Repair Café for free repair services.

Manual

Loading…

User Manual
AMBIENT GAS MEMBRANE THERMOST
Read all the instruction carefully
This thermostat is designed for automatic regulation of heating and
conditioning systems in houses, hotels, schools, offices, workshops and many
other environments, both domestic and industrial. It is also ideal for heating
and air conditioning numerous industrial and civil applications.
SAFETY WARNINGS
During installation and operation of the device, it is necessary to comply
with the following instructions:
1) The device must be installed by a skilled person, in strict compliance with
the connection diagrams
2) Do not power on or connect the device if any part of it is damaged
3) After installation, inaccessibility to the connection terminals without
appropriate tools must be granted
4) The device must be installed and activated in compliance with current
electric systems standards
5) Before accessing the connection terminals, verify that the leads are not live
Code Model Contact Functions
VE018800 KLIMA 2 NA -
VE019600 KLIMA 3 NA + NC -
VE020400 KLIMA 3L NA + NC Power on warning lamp
VE021200 KLIMA SI NA + NC ON/OFF + Power on warning lamp
VE022000 KLIMA IN NA + NC ON/OFF
VE023800 KLIMA SW NA + NC Summer/Winter
VE024600 KLIMA 2V NA + NC 2 speed + Summer/Winter/OFF
VE268900 KLIMA 3V NA + NC 3 speed + OFF
TECHNICAL SPECIFICATIONS
Free mounted single-pole mechanical thermostat
Setting range: +5 / +30°C
• Differential: Δt 1°C
Capacity of the contacts: 16(2,5)A 250V ~ for models KLIMA 2 e KLIMA 3
10(1,5)A 250V ~ for models KLIMA 3L, KLIMA SI, KLIMA IN,
KLIMA SW, KLIMA 2V, KLIMA 3V
Thermal gradient: 1°C / 15 min.
Sensitive element: vapour expansion lung
Class I equipment
Protection degree: IP20
Type of action: 1B
Silver contacts 1000/1000
Break or switching contacts
Pollution degree: 2 (normal)
Voltage pulse: 4kV
Operating temperature: 0 ÷ 40°C
Operating humidity: 20 ÷ 90 %RH noncondensing
INSTALLATION
You are advised to position the thermostat as far as possible in a place that reflects the
average temperature of the whole area. Avoid positioning it near doors, windows, sources
of heat and in places where there is too much or too little ventilation.
The thermostat should be fitted at approximately 1.5 m from the ground.
1) The thermostat can be fitted to the flush-mounting box of the electric system (centre
distance 60 mm) or directly to the wall (centre distance 60 mm);
2) Remove the knob, unscrew the screw of the cover and remove it as shown in the drawing;
3) a) fix the base to the wall
b) connect the thermostat earth by using the terminal marked with the earth symbol
c) follow the wiring diagram inside the cover; fix the flexible inseparable wires to the
relative screw terminals
d) replace the cover, screws and knob.
USER’S GUIDE
1) Set the temperature required by turning the knob;
2) To limit the setting field:
a) Isolate the power supply line
b) Remove the knob
c) Insert the limit markers in the housing
under the knob (17°C ÷ 23°C
d) Return the knob to its housing.
REFERENCE STANDARDS
Conformity with EU directives:
2014/35/EU (LVD)
2014/30/EU (EMCD)
is declared with reference to the following standard:
EN 60730-2-9: Automatic electric command devices for household and similar use.
Part 2: particular provisions for thermosensitive command devices.
ISCOM004-1604
Mod. KLIMA
DIMENSIONS
INSTALLATION
CONNECTIONS
Vemer S.p.A.
I - 32032 Feltre (BL) • Via Camp Lonc, 16
Tel +39 0439 80638 • Fax +39 0439 80619
e-mail: info@vemer.it - web site: www.vemer.it
KLIMA 2
T
+°C
16(2,5)A 250V~
N
L
KLIMA 3
T
+°C
16(2,5)A 250V~
N
L
KLIMA 3L
T
+°C
10(1,5)A 250V~
N
L
KLIMA IN
ON OFF
T
+°C
N
L
10(1,5)A
250V~
KLIMA SI
ON OFF
T
+°C
N
L
10(1,5)A
250V~
KLIMA SW
T
+°C
N
L
10(1,5)A
250V~
KLIMA 2V
OFF
I
II
T
+°C
N
L
10(1,5)A
250V~
KLIMA 3V
T
+°C
III
OFF
I
II
N
L
10(1,5)A
250V~
83,7
76,5
82,9
60
60
31
39
Note:
for “heating” operation
mode, remove the cable
terminal which is inside
the device from terminal
3 to teminal 2.
Download manual in English (PDF, 1 MB)
(Consider the environment and only print this manual if it is really necessary)

Loading…

Rating

Let us know what you think about the Vemer Klima 3V Thermostat by leaving a product rating. Want to share your experiences with this product or ask a question? Please leave a comment at the bottom of the page.
Are you satisfied with the Vemer Klima 3V Thermostat?
Yes No
Be the first to rate this product
0 votes

Join the conversation about this product

Here you can share what you think about the Vemer Klima 3V Thermostat. If you have a question, first carefully read the manual. Requesting a manual can be done by using our contact form.

More about this manual

We understand that it’s nice to have a paper manual for your Vemer Klima 3V Thermostat. You can always download the manual from our website and print it yourself. If you would like to have an original manual, we recommend you contact Vemer. They might be able to provide an original manual. Are you looking for the manual of your Vemer Klima 3V Thermostat in a different language? Choose your preferred language on our homepage and search for the model number to see if we have it available.

Specifications

Brand Vemer
Model Klima 3V
Category Thermostats
File type PDF
File size 1 MB

All manuals for Vemer Thermostats
More manuals of Thermostats

Frequently Asked Questions about Vemer Klima 3V Thermostat

Our support team searches for useful product information and answers to frequently asked questions. If you find an inaccuracy in our frequently asked questions, please let us know by using our contact form.

What is the dead zone of a thermostat? Verified

Many modern thermostats have a dead zone. If the temperature deviates less than 4°C from the set temperature, the system will not heat or cool. This so called dead zone of the thermostat prevents the system from turning on and off too often, saving energy.

This was helpful (1588) Read more

What is the best place to mount a thermostat? Verified

The best place for a thermostat is approximately 1,5 meter above the ground. Never place the thermostat nead a radiator or other heat emitting equipment or in direct sunlight. Choose a room that is used often. In most cases this is the living room.

This was helpful (992) Read more