Manual Vaillant ecoMAX 828/2 E Central Heating Boiler

Need a manual for your Vaillant ecoMAX 828/2 E Central Heating Boiler? Below you can view and download the PDF manual for free in English. This product currently has 3 frequently asked questions, 0 comments and has 0 votes. If this is not the manual you want, please contact us.

Is your product defective and the manual offers no solution? Go to a Repair Café for free repair services.

Manual

Loading…

22
1 General information . . . . . . . . . . . . . . . . . . 2
1.1 For your information . . . . . . . . . . . . . . . . . . . . . 2
1.2 Key to symbols . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.3 Liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.4 Specified use . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.5 EC designation . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2 Safety instructions . . . . . . . . . . . . . . . . . . . 3
2.1 Setup and adjustments . . . . . . . . . . . . . . . . . . . 3
2.2 Gas smell . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2.3 Modifications in and around the boiler . . . . . . 3
2.4 Explosive and flammable materials . . . . . . . . . 3
2.5 Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3 Factory guarantee . . . . . . . . . . . . . . . . . . . . 4
3.1 Your guarantee . . . . . . . . . . . . . . . . . . . . . . . . . 4
3.2 Registering with us . . . . . . . . . . . . . . . . . . . . . . 4
3.3 Immediate help . . . . . . . . . . . . . . . . . . . . . . . . . 4
4 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
4.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
4.1.1 Operating controls . . . . . . . . . . . . . . . . . . . . . . . 4
4.1.2 Advanced multifunctional system display . . . . 5
4.2 Initial checks before turning ON . . . . . . . . . . . 5
4.2.1 Opening the service valves . . . . . . . . . . . . . . . . 5
4.2.2 Checking the water contents . . . . . . . . . . . . . . 5
4.3 Domestic hot water operation . . . . . . . . . . . . . 6
4.3.1 Setting the maximum domestic hot water
temperature control (ecoMAX 800 series only) 6
4.3.2 Warmstart operation
(ecoMAX 800 series only) . . . . . . . . . . . . . . . . . 6
4.3.3 Obtaining hot water (ecoMAX 800 series only) 7
4.4 Heating operation . . . . . . . . . . . . . . . . . . . . . . . 7
4.4.1 Setting the maximum radiator temperature
control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
4.4.2 Setting the external controls . . . . . . . . . . . . . . 8
4.5 Status displays . . . . . . . . . . . . . . . . . . . . . . . . . . 8
4.6 Resetting the appliance . . . . . . . . . . . . . . . . . . . 9
4.7 Turning the boiler OFF . . . . . . . . . . . . . . . . . . . 10
4.7.1 To turn OFF the central heating only
(Summer mode) . . . . . . . . . . . . . . . . . . . . . . . . . 10
4.7.2 To turn OFF central heating and hot water
for short periods of time . . . . . . . . . . . . . . . . . . 10
4.8 Turning the boiler OFF
(ecoMAX 600 series only) . . . . . . . . . . . . . . . . . 10
4.8.1 To turn OFF the central heating . . . . . . . . . . . . 10
4.8.2 To turn boiler OFF for short periods of time . 10
4.9 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . 11
4.10 Care and maintenance . . . . . . . . . . . . . . . . . . . 11
4.11 Frost-protection . . . . . . . . . . . . . . . . . . . . . . . . . 11
1 General information
1.1 For your information
Thank you for choosing a Vaillant boiler. The information
given in this booklet will enable you to obtain the best
performance from your boiler.
ecoMAX 800 series provides both central heating and
domestic hot water, with the domestic hot water
supplied directly from the boiler. The boiler will operate
automatically to provide domestic hot water whenever a
hot water tap is opened, and automatically adjusts to
meet the demand for both central heating and domestic
hot water in the most economical way.
ecoMAX 600 series provides central heating and
domestic hot water where a separate indirect hot water
cylinder is also incorporated to the system.
The benchmark logbook should be completed by the
installer and/or the commissioning engineer and handed
to the user.
All CORGI Registered Installers carry a CORGI ID card,
and have a registration number.
Both should be recorded in your Benchmark Log Book.
You can check your installer by calling CORGI direct on
01256 372300.
If, after reading these instructions, you have any
questions on the operation of the boiler, please contact
either your installer or Vaillant Technical Department.
1.2 Key to symbols
Attention!
Important Note
Note!
This symbol is used to indicate important
instructions.
This symbol is used to indicate a required step.
1.3 Liability
Attention!
We can accept no liability whatsoever for dama-
ge or injury resulting from failure to observe
these instructions.
Table of contents
1 General information
Instructions for use ecoMAX
Download manual in English (PDF, 0.58 MB)
(Consider the environment and only print this manual if it is really necessary)

Loading…

Rating

Let us know what you think about the Vaillant ecoMAX 828/2 E Central Heating Boiler by leaving a product rating. Want to share your experiences with this product or ask a question? Please leave a comment at the bottom of the page.
Are you satisfied with the Vaillant ecoMAX 828/2 E Central Heating Boiler?
Yes No
Be the first to rate this product
0 votes

Join the conversation about this product

Here you can share what you think about the Vaillant ecoMAX 828/2 E Central Heating Boiler. If you have a question, first carefully read the manual. Requesting a manual can be done by using our contact form.

More about this manual

We understand that it’s nice to have a paper manual for your Vaillant ecoMAX 828/2 E Central Heating Boiler. You can always download the manual from our website and print it yourself. If you would like to have an original manual, we recommend you contact Vaillant. They might be able to provide an original manual. Are you looking for the manual of your Vaillant ecoMAX 828/2 E Central Heating Boiler in a different language? Choose your preferred language on our homepage and search for the model number to see if we have it available.

Specifications

Brand Vaillant
Model ecoMAX 828/2 E
Category Central Heating Boilers
File type PDF
File size 0.58 MB

All manuals for Vaillant Central Heating Boilers
More manuals of Central Heating Boilers

Frequently Asked Questions about Vaillant ecoMAX 828/2 E Central Heating Boiler

Our support team searches for useful product information and answers to frequently asked questions. If you find an inaccuracy in our frequently asked questions, please let us know by using our contact form.

What is the best pressure for my central heating boiler? Verified

The right pressure is between 1 and 1,5 bar. Never let the pressure rise above 2 bar.

This was helpful (508) Read more

The piping and radiators make noise. What is causing this? Verified

There is probably air in the heating system. It's best to purge the air from the system.

This was helpful (275) Read more

My Vaillant central heating boiler displays error E13, what does this mean? Verified

Error E13 indicates that the water in the system is not flowing properly. This might be because too few radiators are turned on. It is also possible that the bypass valve is not set correctly or that there is blockage in the system. In these last two cases it is best contact a mechanic.

This was helpful (20) Read more
Manual Vaillant ecoMAX 828/2 E Central Heating Boiler