Contents i
Contents
CONTENTS ......................................................................................................................I
WELCOME TO THE ADVIA
®
2120 HEMATOLOGY SYSTEM..........................1-1
O
VERVIEW ..................................................................................................................1-2
C
OMPONENTS..............................................................................................................1-3
H
OW THE ADVIA 2120 HEMATOLOGY SYSTEM WORKS.......................................... 1-14
H
OW THE ADVIA 2120 SOFTWARE WORKS .............................................................1-15
R
ESULTS.................................................................................................................... 1-18
S
PECIFICATIONS ........................................................................................................1-19
TURNING THE SYSTEM ON / OFF.........................................................................2-1
O
VERVIEW ..................................................................................................................2-2
T
URNING THE SYSTEM ON............................................................................................2-2
T
URNING THE SYSTEM OFF ..........................................................................................2-4
DAILY ROUTINE........................................................................................................3-1
S
TARTING EACH SHIFT................................................................................................3-2
P
ROCESSING THE SAMPLES..........................................................................................3-5
E
NDING EACH SHIFT ................................................................................................. 3-10
MAINTAINING THE ANALYZER...........................................................................4-1
S
CHEDULE...................................................................................................................4-2
S
YSTEM WASH ............................................................................................................4-3
C
LEANING THE CENTERING COLLAR...........................................................................4-3
C
LEANING THE SHEAR VALVE AND ASPIRATION PATHWAYS IN THE UFC..................4-7
C
LEANING THE SHEAR VALVE ....................................................................................4-7
I
NSPECTING AND CLEANING THE SYRINGE PLUNGERS ..............................................4-10
R
EPLACING THE SAMPLER NEEDLES ......................................................................... 4-12
R
EPLACING THE SHEATH FILTERS.............................................................................4-15
R
EPLACING THE 50 OR 1000-µL SYRINGE PLUNGERS................................................4-16
C
LEANING THE AIR-CIRCULATION FILTER ................................................................4-19
I
NSPECT THE PEROX-CAP VENT HOLE FOR BUILDUP ................................................4-20
C
LEANING THE AUTOSAMPLER ASPIRATE ASSEMBLY............................................... 4-20
TROUBLESHOOTING THE ANALYZER...............................................................5-1
A
LIGNMENTS AND ADJUSTMENTS ...............................................................................5-2
C
LEANING PROCEDURES .............................................................................................5-5
R
EPAIR AND REPLACEMENT......................................................................................5-24
T
ROUBLESHOOTING TIPS...........................................................................................5-45
FLAGS...........................................................................................................................6-1
M
ORPHOLOGY FLAGS..................................................................................................6-3
S
AMPLE/SYSTEM FLAGS............................................................................................ 6-21
STATUS-LINE MESSAGES.......................................................................................7-1
METHODS....................................................................................................................8-1
B
ASOPHIL / LOBULARITY METHOD .............................................................................8-3
CSF
METHOD............................................................................................................8-16
H
EMOGLOBIN METHOD.............................................................................................8-21
Join the conversation about this product
Here you can share what you think about the Siemens Advia 2120 Hematology System. If you have a question, first carefully read the manual. Requesting a manual can be done by using our contact form.