EMERGENCY STOP
The switching-off of the machine can be performed
by pressing the “ON-OFF” switch on pos. “OFF
(0)”. In order to avoid situations of imminent or
close hazard, the authorized operators must
compulsorily perform the following operations:
1. Press the “on-off” switch On pos. “Off (0)” in the right time.
2. Immediately inform the “safety manager” of the emergency (if
the machine is used in a company).
1. Switch off the machine by pressing the “ON-OFF” switch on
pos. “OFF (0)”;
2. Disconnect the machine from the mains by removing the
power supply plug from the proper outlet;
3. Disconnect the tool from the air tube (extension);
4. Disconnect the air tube (extension) from the fast air outlet tap
of the machine;
5. Drain the condensate from the tank only in case of work cycle
end.
RESTORABLE THERMAL PROTECTION TRIPPING
RESET
Should a current overload and/or short-circuit
occur in the electric plant of the machine,
the restorable thermal switch trips stopping
the electric motor. To reset the restorable
thermal switch, proceed as follows;
1. Press the “ON-OFF” switch on pos. “OFF (0)”;
2. Press the restorable thermal push-button;
3. Before restarting the machine wait some minutes.
bar
0
Should the machine, after having performed the rest, not
switch on, the charged operator must compulsory seek
the intervention of the maintenance technical engineers
and/or of the authorized dealer.
MACHINE SWITCHING OFF
At the end of the work cycle, switch
off the machine as follows:
bar
0
CONNECTIONS
The machine can be connected to the mains
by inserting the power supply plug in the
proper outlet.
ELECTRICAL CONNECTIONS
The mains to which the machine is connected
must comply with the requirements foreseen by the
regulation in force in the country of use, as well as
meet the technical features quoted in par.2 And be
equipped with a proper “earthing” plant.
Any type of electric material used for the connection
must suit the use, be marked “ce” if subjected to the
low voltage directive 2006/95/ec, and comply with the
requirements set forth by the regulations in force in
the country of use of the machine.
The inobservance of the above described warnings
can cause irreparable damages to the electric
equipment of the machine and the following
expiration of the warranty.
The manufacturers declines all liability for fauilts or
malfunctions of the machine due to voltage sudden
bar
0
changes exceeding the tolerances foreseen by the
distributing entity (voltage ± 10% - frequency ± 2%).
Should it be necessary, it is compulsory to connect
the machine exclusively to generating sets with a
power greater than the installed electric power. To
support the absorption peak at start.
It is strictly forbidden to use air tubes (extensions),
ttings, and tools not suitable and/or not complying with
the regulations in force.
It is compulsory to use air tubes (extensions), ttings,
and tools, complying with the provisions contained in
the use and maintenance instructions supplied by the
related manufacturers.
The anufacturer declines all liability for damages to
persons, animals and things due to the inobservance of
the above described warnings.
CONNECTION OF THE AIR TUBE (EXTENSION)
AND OF THE TOOLS
1.
Connect the tools to the air tube (extension);
2.
Connect the air tube (extension) to the
fast air outlet tap of the machine.
SWITCHING ON AFTER AN EMERGENCY STOP
Only and exclusively after having removed the
emergency causes and having carefully assessed
that the same have not caused damaged and/or
anomalies to the machine, with the consent of the
“Safety Manager” (In case the machine is used in
a company), switch on the machine as described.
EMERGENCY STOP
contained in the use and maintenance instructions
supplied by the related manufacturers.
6. Perform the processing (the machine restarts
automatically when the operation pressure falls
under 7 bar);
7. Once the processing has ended, switch off the
machine as described.
7
EN
Download manual in English (PDF, 2.76 MB)
(Consider the environment and only print this manual if it is really necessary)

Loading…

Rating

Let us know what you think about the Senco AC8305 Compressor by leaving a product rating. Want to share your experiences with this product or ask a question? Please leave a comment at the bottom of the page.
Are you satisfied with the Senco AC8305 Compressor?
Yes No
Be the first to rate this product
0 votes

Join the conversation about this product

Here you can share what you think about the Senco AC8305 Compressor. If you have a question, first carefully read the manual. Requesting a manual can be done by using our contact form.

More about this manual

We understand that it’s nice to have a paper manual for your Senco AC8305 Compressor. You can always download the manual from our website and print it yourself. If you would like to have an original manual, we recommend you contact Senco. They might be able to provide an original manual. Are you looking for the manual of your Senco AC8305 Compressor in a different language? Choose your preferred language on our homepage and search for the model number to see if we have it available.

Specifications

Brand Senco
Model AC8305
Category Compressors
File type PDF
File size 2.76 MB

All manuals for Senco Compressors
More manuals of Compressors

Manual Senco AC8305 Compressor

Related products

Related categories