TCP ID0 BI0 0SE 023097D4 280114
ADJUSTABLE PLATES
Brand Model Support Notches to break Side hole-cover adaptors
BTICINO
®
light A 2 no
light tech A 2 no
Living International A 2 no
Matix A 2 Width 2.5 mm
Luna B 3 no
Axolute B 3 no
VIMAR
®
Idea A 1 Width 4 mm
Idea Rondò A 1 Width 4 mm
Plana B 3 no
Eikon B 3 no
GEWISS
®
Playbus A 2 Width 4 mm
Playbus Young A 2 Width 4 mm
Chorus B 3 no
AVE
®
Banquise A none Width 4 mm
Sistema 45 A none Width 4 mm
Noir A none Width 4 mm
SIEMENS
®
Delta Futura A 2 Width 4 mm
LEGRAND
®
Ergo A 2 no
Cross A 2 no
Vela A 2 no
MASTER
®
Modo B none no
Mix B none no
PLATE SUPPORT
The timer thermostat was specifically studied to fit many of the finishing plates present on the market.
Choose support A or B depending on the type of finishing plate used. If necessary, intervene on the support as described
hereafter.
BTICINO
®
, VIMAR
®
, GEWISS
®
, AVE
®
, SIEMENS
®
, LEGRAND
®
, MASTER
®
are brands registered by their legitimate
owners.
SUPPORT B
3
3
3
3
SUPPORT A
1
2
2
1
2
2
1
1
2 2
Side adaptor
insertion
4
TCP ID0 BI0 0SE 023097A4 280114
FREETIME
c
cc
c
Code TCP ID0 BI- 0SE
RECESSED DAILY DIGITAL CHRONOSTAT
Possibility of setting room temperature at two levels
(Comfort and Economy)
Ample backlit display
Dip-Switches on front to program the time
Possibility of Manual mode
Possibility of Offset adjustment
Possibility of Antifreeze temperature adjustment
Buttons for digital setting of Comfort and Economy temperatures
Shutdown with Antifreeze function not deactivated
Fixing on 503 box (3-module recessed box)
Via Prosdocimo, 30
I-36061 BASSANO DEL GRAPPA (VI)
Tel.: +39.0424.567842
Fax.: +39.0424.567849
http://www.seitron.it
e-mail: inf[email protected]
s
e
i
t
r
o
n
Fig. 2: Assembly layout.
BATTERY COMPARTMENT
Fig. 1: Outward appearance.
MANUAL
BUTTON
ON / OFF BUTTON
TIME/TEMPERATURE
BUTTON
RESET
BUTTON
TAB
SWITCHES FOR SETTING THE COMFORT/ECONOMY MODE
Interval 0 .. 5 Interval 9 .. 10 Interval 6 .. 6.30
OK BUTTON
COMFORT TEMPERATURE
INCREASE BUTTON
ECONOMY TEMPERATURE
INCREASE BUTTON
1
Fig. 3: Wiring diagram
N
L
LOAD
765
LOAD
7 8 9
Download manual in English (PDF, 1.17 MB)
(Consider the environment and only print this manual if it is really necessary)

Loading…

Rating

Let us know what you think about the Seitron TCP ID0 BI-0SE Freetime Thermostat by leaving a product rating. Want to share your experiences with this product or ask a question? Please leave a comment at the bottom of the page.
Are you satisfied with the Seitron TCP ID0 BI-0SE Freetime Thermostat?
Yes No
Be the first to rate this product
0 votes

Join the conversation about this product

Here you can share what you think about the Seitron TCP ID0 BI-0SE Freetime Thermostat. If you have a question, first carefully read the manual. Requesting a manual can be done by using our contact form.

More about this manual

We understand that it’s nice to have a paper manual for your Seitron TCP ID0 BI-0SE Freetime Thermostat. You can always download the manual from our website and print it yourself. If you would like to have an original manual, we recommend you contact Seitron. They might be able to provide an original manual. Are you looking for the manual of your Seitron TCP ID0 BI-0SE Freetime Thermostat in a different language? Choose your preferred language on our homepage and search for the model number to see if we have it available.

Specifications

Brand Seitron
Model TCP ID0 BI-0SE Freetime
Category Thermostats
File type PDF
File size 1.17 MB

All manuals for Seitron Thermostats
More manuals of Thermostats

Frequently Asked Questions about Seitron TCP ID0 BI-0SE Freetime Thermostat

Our support team searches for useful product information and answers to frequently asked questions. If you find an inaccuracy in our frequently asked questions, please let us know by using our contact form.

What is the dead zone of a thermostat? Verified

Many modern thermostats have a dead zone. If the temperature deviates less than 4°C from the set temperature, the system will not heat or cool. This so called dead zone of the thermostat prevents the system from turning on and off too often, saving energy.

This was helpful (1588) Read more

What is the best place to mount a thermostat? Verified

The best place for a thermostat is approximately 1,5 meter above the ground. Never place the thermostat nead a radiator or other heat emitting equipment or in direct sunlight. Choose a room that is used often. In most cases this is the living room.

This was helpful (990) Read more