ESP-TM2 Controller
3
Wiring Connections
Connect Valves
A
Route all eld wires through the opening at the bottom
of the unit, or through the knock-out in back of the unit.
Attach conduit if desired, as shown.
B
Connect one wire from each valve to one of the numbered
station terminals (1-12) on the controller, as shown.
C
Connect a eld common wire (C) to the common terminal
(C) on the controller. Then connect the remaining wire
from each valve to the eld common wire, as shown.
NOTE: The ESP-TM2 controller supports one valve
solenoid per station terminal.
CONNECT
120 VAC
RESET
ACCESSORY
12345678
24VAC SENS
CM
9101112
1
2
4
MASTER
VALVE
C
MV
1
2
S
3
Connect Master Valve (optional)
D
Connect a wire from the master valve (M) to the master
valve terminal (M) on the controller. Then connect the
remaining wire from the master valve to the eld common
wire, as shown.
Connect Pump Start Relay (optional)
The ESP-TM2 can control a pump start relay, to turn the
pump on and off as needed.
A
Connect a wire from the pump start relay (PSR) to the
master valve terminal (M) on the controller. Then connect
another wire from the pump start relay to the eld
common wire, as shown.
B
To avoid the possibility of damage to the pump, connect
a short jumper wire from any unused terminal(s) to the
nearest terminal in use, as shown.
CONNECT
120 VAC
RESET
ACCESSORY
12345678
24VAC SENS
CM
9101112
NOTE:
Connection
to pump
and external
power not
shown. Refer
to pump
installation
instructions.
1
PUMP START
RELAY
2
C
PSR
1
2
NOTE: The ESP-TM2 controller DOES NOT provide
power for a pump. The relay must be wired according to
manufacturer instructions.
Only the following Rain Bird pump start relay models are
compatible with the ESP-TM2:
Description Model # Volts
Universal Pump Relay PSR110IC 110V
Universal Pump Relay PSR220IC 220V
Download manual in English (PDF, 0.66 MB)
(Consider the environment and only print this manual if it is really necessary)

Loading…

Rating

Let us know what you think about the Rainbird ESP-TM2 Water Computer by leaving a product rating. Want to share your experiences with this product or ask a question? Please leave a comment at the bottom of the page.
Are you satisfied with the Rainbird ESP-TM2 Water Computer?
Yes No
Be the first to rate this product
0 votes

Join the conversation about this product

Here you can share what you think about the Rainbird ESP-TM2 Water Computer. If you have a question, first carefully read the manual. Requesting a manual can be done by using our contact form.

More about this manual

We understand that it’s nice to have a paper manual for your Rainbird ESP-TM2 Water Computer. You can always download the manual from our website and print it yourself. If you would like to have an original manual, we recommend you contact Rainbird. They might be able to provide an original manual. Are you looking for the manual of your Rainbird ESP-TM2 Water Computer in a different language? Choose your preferred language on our homepage and search for the model number to see if we have it available.

Specifications

Brand Rainbird
Model ESP-TM2
Category Water Computers
File type PDF
File size 0.66 MB

All manuals for Rainbird Water Computers
More manuals of Water Computers

Manual Rainbird ESP-TM2 Water Computer

Related products

Related categories