This air conditioner employs a “Slinger-Up System” which is designed to splash the condensed water on the
condenser coil for maximum cooling efficiency, thus producing a splashing sound. If the splashing sound annoys
you, you can provide an outside drainage by using the following procedure which may, however, cause a small
loss of performance.
NOTE: If the unit is installed at coastal area, drainage of condensed water is recommended to prevent the
condenser being corroded easily.
Select an installation location that can support the weight of the air
conditioner and on
e that will not cause increased operating noise
and vibration.
Ensure that airflow and noise from the rear side of the unit (outdoor)
when installed do not disturb neighbouring residents.
Obstacles placed in front of the air outlet on the rear side of the unit
(outdoor), or covers placed over it will cause excessive noise and
deterioration in performance.
2
Install the drain pan.
NOISE CONSIDERATIONS
Repositioning or transfer of the air conditioner due to renovation or moving requires an additional service
charge. Please consult your dealer before moving.
TRANSFERRING
5
ENERGY SAVING HINTS
Do not overcool the room. This may affect your well-being as well as increase power consumption.
The cooling capacity of the room air conditioner must match the room size for efficient and satisfactory
operation.
Keep all doors and windows closed. Prevent hot air from entering and cool air from escaping.
Ensure that curtains and drapes are always closed to keep out direct sunlight during cooling operation.
Avoid heat
Clean the air filter every 2 weeks. Dirty filters may reduce cooling efficiency.
6
CARE AND MAINTENANCE
Always turn off the air conditioner and the main power supply before
clean the unit.
Switch off the power supply if the unit is not going to be used for a
long period of time.
Clean the cabinet, front grille with a mild soap or detergent and lukewarm water.
The front intake grille can be easily removed for cleaning purposes (refer to
Remove the front intake grille
procedures). Gently wash it with water and a sponge.
The filter can be easily cleaned using a vacuum cleaner. Vacuum the front of the filter and then wash the rear
with water. If it is badly soiled, wash with a mild household detergent.
Do not clean with benzene, thinner, scouring powder or cloth soaked in caustic chemicals.
If the unit is extremely dirty, heat transfer is less efficient and the unit may not cool effectively. Please contact
Shun Hing Electric Service Centre Ltd. for an a
nnual check. (Annual check is not covered under warranty)
If the air filter becomes clogged with dust, the cooling capacity will drop, and 6% of the electricity used to
operate the air conditioner will be wasted.
NOTE: Do not dry the front panel or the air filter in direct sunlight. (Exposure to direct sunlight may discolour or
deform the panel.)
PRE-SEASON
INSPECTION
Is the discharged air cold?
After 15 minutes of operation, it is normal for the temperature difference between intake and outlet air to be
more than 8°C for cooling.
Are the air intake or outlet vanes of the indoor or outdoor side obstructed?
RECOMMENDED INSPECTION
Usage over several seasons will reduce performance as the unit becomes dirty.
A dirty unit may produce foul odours and dust may clog the dehumidifying drainage.
Seasonal inspection is recommended in addition to regular cleaning. Consult Shun Hing Electric Service
Centre Ltd..
Check the following points before calling for repairs or service. If the malfunction persists,
please contact Shun Hing Electric Service Centre Ltd..
BEFORE
7
BEFORE CALLING FOR SERVICE
CONDENSED WATER DRAINAGE
INSTALLATION PROCEDURES
4
AIR CONDITIONER INSTALLATION
NOTE: Drain hose or tubing can be purchased
locally to satisfy your particular needs.
4
Slide the chassis back into the cabinet. Lock the
chassis to the cabinet reusing the chassis
locking bracket and screw.
Always use at the rated voltage and with a specific air conditioning circuit.
This equipment must be earthed and strongly recommended to be installed with Earth Leakage Circuit
Breaker (ELCB) or Residual Current Device (RCD). Otherwise, it may cause electrical shock or fire in case
of malfunction.
Time delay fuse or circuit breaker rating is 16 Ampere for CW-V1815EA.
Nominal cross sectional area of power supply wire must be 3 core x 2.5 mm
2
or above.
The power supply must be from an independent circuit.
All electrical installations must be made in accordance with local wiring and safety regulations wherever
applicable.
There must be a double pole switch with minimum of 3.5 mm contact gap in the fixed installation circuit.
Please engage an authorized dealer or specialist for the installation work.
ELECTRICAL WORK
3
Connect a drain hose. Fit the drain hose to the
drain pan.
Screws
INTERNAL VIEW
Drain pan
EXTERNAL VIEW
Drain hose
To call Shun Hing Electric Service Centre Ltd. IMMEDIATELY
Turn off the power and contact Shun Hing Electric Service Centre Ltd. as soon as any of the
following events occur.
The circuit breaker frequently trips.
If water or foreign objects have accidentally entered the air conditioner
.
If there is abnormal sound during operation.
NOTE:
1. The enclosure opposing the room side is splash proof (IPX4).
2. Do not install this appliance in a laundry room or other locations where water may drip from the ceiling, etc.
3. If the supply cord is damaged or need to be replaced, it must be replaced by the manufacturer or its service
agent or a similarly qualified person in order to avoid a hazard.
Printed in Philippines
Condition
1
If the unit is noisy during operation.
The following sounds are normal during operation:
A low humming sound indicating that the unit is operating.
A soft clicking sound when the compressor turns on and off.
A flowing sound due to circulation of the refrigerant when
the compressor is turned on.
A splashing sound indicating condensation in the condenser
coil.
If you hear other noises, please contact Shun Hing Electric
Service Centre Ltd..
Condition
2
If the unit does not operate.
The main power cord is not plugged in.
The main circuit breaker has tripped.
Condition
3
If the unit does not cool properly.
The thermostat control knob has been set at below 6.
The room is too big for the unit’s cooling capacity.
The ventilation lever is set at OPEN.
The air circulation is impeded by curtains or furniture.
After 15 minutes of operation, it is normal for the
temperature difference between intake and outlet air to be
more than 8°C for cooling.
If water drips off the rear of the unit.
Humidity is high.
Condensed water is overflowing.
To rectify the problem, mount a drain pan to the unit.
Condition
4
If water drips inside the room.
The unit is tilted inward. To rectify this, tilt the unit slightly
outward.
Mount the drain pan if you prefer.
The drain pan may be blocked.
Condition
5
Clockwise
1
Remove the rubber plug and chassis locking
bracket from the cabinet. Then slide the chassis
out from the cabinet.
Install the drain pan at the right corner of the
cabinet using 2 screws.
Underside view with
drain pan and hose in
place.
Remove the
rubber plug
Counter
clockwise
Chassis locking
bracket
6
Attach the front grille to the cabinet and fasten it with screws.
7
Slide the fro
Insert hook of string in the hole provision of the intake grille.
nt intake grille slightly to the right to reattach
the tabs and then push it down to close tight.
8
4
Depending upon the location of the AC outlet, route
the AC cord to either the left or right side while
installing the front grille.
5
Slide the chassis into the cabinet.
Lock the chassis to the cabinet reusing the
chassis locking bracket and screw.
Clockwise
This figure shows the AC cord routed to the left side.
3
Place cabinet into the installation hole.
Insert front grille tabs
into the cabinet slots
Attach air filter to the front grille. (See anti-bacterial filter installation
instructions included in this package)
ACXF550114
F568442_EN 1/20/09, 5:29 PM1
Download manual in English (PDF, 12.63 MB)
(Consider the environment and only print this manual if it is really necessary)

Loading…

Rating

Let us know what you think about the Panasonic CW-V1815EA Air Conditioner by leaving a product rating. Want to share your experiences with this product or ask a question? Please leave a comment at the bottom of the page.
Are you satisfied with the Panasonic CW-V1815EA Air Conditioner?
Yes No
Be the first to rate this product
0 votes

Join the conversation about this product

Here you can share what you think about the Panasonic CW-V1815EA Air Conditioner. If you have a question, first carefully read the manual. Requesting a manual can be done by using our contact form.

More about this manual

We understand that it’s nice to have a paper manual for your Panasonic CW-V1815EA Air Conditioner. You can always download the manual from our website and print it yourself. If you would like to have an original manual, we recommend you contact Panasonic. They might be able to provide an original manual. Are you looking for the manual of your Panasonic CW-V1815EA Air Conditioner in a different language? Choose your preferred language on our homepage and search for the model number to see if we have it available.

Specifications

Brand Panasonic
Model CW-V1815EA
Category Air Conditioners
File type PDF
File size 12.63 MB

All manuals for Panasonic Air Conditioners
More manuals of Air Conditioners

Frequently Asked Questions about Panasonic CW-V1815EA Air Conditioner

Our support team searches for useful product information and answers to frequently asked questions. If you find an inaccuracy in our frequently asked questions, please let us know by using our contact form.

How often should I clean or replace the filters in my air conditioner? Verified

It's advisable to check the filters of your air conditioner 4 times a year. Dirty filters can be cleaned with the use of a vacuum cleaner or can be washed, depending on which type they are. During maintenance a professional should judge whether it is time to replace the filters.

This was helpful (2678) Read more

What does BTU stand for? Verified

BTU stands for British Thermal Unit. This is unit to indicate the capacity to cool.

This was helpful (946) Read more

Does every air conditioner also function as a dehumidifier? Verified

The cold air produced by an air conditioner often has a relatively low humidity. However, the effect is less than when using an actual dehumidifier. Some air conditioners do have a special feature to dehumidify the air.

This was helpful (703) Read more

What is R-410A? Verified

R-410A is a cooling agent that is used in appliances that cool up to 0°C, like refrigerators and air conditioners. It is the replacement of older cooling agents and does not damage the ozon layer.

This was helpful (480) Read more

What is the best place to mount the indoor unit of a split-type air conditioner? Verified

This depends on the space, but in general the following rules can be followed. Make sure that there is nothing obstructing the airflow. Make sure the location is accessible for maintenance. Mount the unit at least 2 meters from the ground.

This was helpful (346) Read more

Can I place my mobile air conditioner in a cabinet to get it out of sight? Verified

No, absolutely not. A mobile air conditioner needs space to allow airflow and air intake. In a small space the device can overheat.

This was helpful (345) Read more

Does an air conditioner have a negative influence on air quality? Verified

If the air conditioner has been properly maintained then it will have no influence on air quality. If for example a filter hasn't been replaced for a long time, or other maintenance has not been performed, than an air conditioner can produce dirty air.

This was helpful (341) Read more