INSTRUCCIONES PARA REPARAR APARATOS QUE CONTENGAN R 290
1 INSTRUCCIONES GENERALES
1.1 Comprobaciones en la zona
Antes de comenzar a trabajar en sistemas que contienen refrigerantes inflamables, es necesario realizar
controles de seguridad para garantizar que se minimice el riesgo de ignición. Para reparar el sistema de
refrigeración, se deben cumplir las siguientes precauciones antes de realizar trabajos en el sistema.
1.2 Procedimiento de trabajo
El trabajo se realizará bajo procedimiento controlado, de forma que se minimice el riesgo de presencia
de algún gas o sustancia inflamable mientras se lleva a cabo el trabajo
1.3 Área general de trabajo
Todo el personal de mantenimiento y todas las personas que trabajen en el área local deberán recibir
instrucciones sobre la naturaleza del trabajo que se va a llevar a cabo. Se debe evitar el trabajo en
espacios reducidos. Se deberá seccionar el área alrededor del espacio de trabajo. Hay que comprobar,
mediante el control del material inflamable, que las condiciones dentro del área se consideren seguras.
1.4 Comprobar presencia de refrigerante
Se debe verificar el área con un detector de fugas refrigerante que sea apropiado, antes y durante el
trabajo, con el fin de asegurar que el técnico sea consciente de atmósferas potencialmente inflamables.
Hay que comprobar que el equipo de detección de fugas utilizado sea adecuado para su uso con
refrigerantes inflamables, es decir, que no produzca chispas y esté sellado de forma adecuada o
intrínsecamente segura.
1.5 Presencia de extintor
Si se va a realizar un trabajo en caliente en el equipo de refrigeración o en cualquier parte asociada,
deberá estar disponible un equipo de extinción de incendios apropiado. Debe haber un extintor de
polvo seco o de CO2 junto al área de carga.
1.6 Sin fuentes de ignición
Ninguna persona que realice trabajos relacionados con un sistema de refrigeración que implique
exponer tuberías que contengan o hayan contenido refrigerante inflamable deberá usar fuentes de
ignición, de tal manera que pudiera provocar riesgo de incendio o de explosión. Todas las posibles
fuentes de ignición, incluido el humo de cigarrillos, deben mantenerse lo suficientemente alejados del
lugar de instalación, reparación, extracción y eliminación, durante el tiempo en el cual sea posible que
se pueda liberar refrigerante inflamable al espacio de alrededor. Antes de realizar el trabajo, se debe
inspeccionar el área alrededor del equipo para asegurarse de que no haya riesgos inflamables ni
riesgos de ignición. Se mostrarán letreros de "Prohibido fumar".
1.7 Área ventilada
Hay que asegurarse de que el área esté al aire libre o de que esté adecuadamente ventilada antes de
ingresar al sistema o antes de realizar cualquier trabajo en caliente. Un grado de ventilación deberá
continuar durante el período en que se realice el trabajo. La ventilación debería dispersar de forma
segura cualquier refrigerante liberado y expulsarlo preferentemente de forma externa a la atmósfera.
1.8 Comprobaciones del equipo de refrigeración
Download manual in English (PDF, 1.87 MB)
(Consider the environment and only print this manual if it is really necessary)

Loading…

Rating

Let us know what you think about the Orbegozo ADRW 125 Air Conditioner by leaving a product rating. Want to share your experiences with this product or ask a question? Please leave a comment at the bottom of the page.
Are you satisfied with the Orbegozo ADRW 125 Air Conditioner?
Yes No
Be the first to rate this product
0 votes

Join the conversation about this product

Here you can share what you think about the Orbegozo ADRW 125 Air Conditioner. If you have a question, first carefully read the manual. Requesting a manual can be done by using our contact form.

More about this manual

We understand that it’s nice to have a paper manual for your Orbegozo ADRW 125 Air Conditioner. You can always download the manual from our website and print it yourself. If you would like to have an original manual, we recommend you contact Orbegozo. They might be able to provide an original manual. Are you looking for the manual of your Orbegozo ADRW 125 Air Conditioner in a different language? Choose your preferred language on our homepage and search for the model number to see if we have it available.

Specifications

Brand Orbegozo
Model ADRW 125
Category Air Conditioners
File type PDF
File size 1.87 MB

All manuals for Orbegozo Air Conditioners
More manuals of Air Conditioners

Frequently Asked Questions about Orbegozo ADRW 125 Air Conditioner

Our support team searches for useful product information and answers to frequently asked questions. If you find an inaccuracy in our frequently asked questions, please let us know by using our contact form.

How often should I clean or replace the filters in my air conditioner? Verified

It's advisable to check the filters of your air conditioner 4 times a year. Dirty filters can be cleaned with the use of a vacuum cleaner or can be washed, depending on which type they are. During maintenance a professional should judge whether it is time to replace the filters.

This was helpful (2704) Read more

What does BTU stand for? Verified

BTU stands for British Thermal Unit. This is unit to indicate the capacity to cool.

This was helpful (971) Read more

Does every air conditioner also function as a dehumidifier? Verified

The cold air produced by an air conditioner often has a relatively low humidity. However, the effect is less than when using an actual dehumidifier. Some air conditioners do have a special feature to dehumidify the air.

This was helpful (725) Read more

What is R-410A? Verified

R-410A is a cooling agent that is used in appliances that cool up to 0°C, like refrigerators and air conditioners. It is the replacement of older cooling agents and does not damage the ozon layer.

This was helpful (500) Read more

Does an air conditioner have a negative influence on air quality? Verified

If the air conditioner has been properly maintained then it will have no influence on air quality. If for example a filter hasn't been replaced for a long time, or other maintenance has not been performed, than an air conditioner can produce dirty air.

This was helpful (358) Read more

What is the best place to mount the indoor unit of a split-type air conditioner? Verified

This depends on the space, but in general the following rules can be followed. Make sure that there is nothing obstructing the airflow. Make sure the location is accessible for maintenance. Mount the unit at least 2 meters from the ground.

This was helpful (357) Read more

Can I place my mobile air conditioner in a cabinet to get it out of sight? Verified

No, absolutely not. A mobile air conditioner needs space to allow airflow and air intake. In a small space the device can overheat.