CONVERSIONS
8) UNIVERSAL LP GAS TO NATURAL GAS
CONVERSION PROCEDURE
Appliance models: Gas Vitroceramic hotplate
models:
1. Remove each burner cap and burner skirt.
2. Remove the Universal LP Gas main injector with
a 7 mm/VF tube spanner and replace with the
appropriate size Natural Gas injector for each
burner. The following injector sizes are required for
Natural Gas:
Burner Main injector
Wok 1.75 B mm
Rapid 1.55 mm
Semi Rapid Reduced 1.05 mm
Semi Rapid 1.20 mm
Auxiliary 0.90 mm
3. Shut off gas supply to the appliance.
4. Disconnect gas inlet pipe from the Universal LP
Gas test point inlet fitting.
5. Remove the Universal LP Gas test point inlet
fitting from the appliance.
6. Fit the Natural Gas Regulator supplied in the
conversion kit.
7. Connect the gas supply to the Regulator.
8. Check for gas leaks. Do not use a naked flame
to check for gas leaks.
9. Adjust the gas pressure to 1.00 kPa.
10. Remove the control knob, with a thin shaft blade
screwdriver down the centre of each gas valve
shaft, screw the by-pass injector anti-clockwise.
Test the appliance on both high and low flame for
each burner. If the burner fails to remain alight or
the flame is not stable on the simmer setting, adjust
the by-pass screw, until flame is stable.
11. If not already removed, remove the Only for
use with Universal LP Gas” label adhered to the
bottom panel near the gas connection.
12. Fit the new data label included in the gas
conversion kit.
9) NATURAL GAS TO UNIVERSAL LP GAS
CONVERSION PROCEDURE
Appliance models: Gas Vitroceramic hotplate
models:
1. Remove each burner cap and burner skirt.
2. Remove the Natural Gas main injector with a 7
mm/VF tube spanner and replace with the
appropriate size Universal LP Gas main injector for
each burner. The following injector sizes are required
for Universal LP Gas:
Burner Main injector
Wok
1.00 B
mm
Rapid 0.91 mm
Semi Rapid Reduced 0.60 mm
Semi Rapid 0.70 mm
Auxiliary 0.53 mm
3. Remove the control knob, with a thin shaft blade
screwdriver down the centre of each gas valve
shaft, screw the by-pass injector fully clockwise.
4. Shut off gas supply to the appliance.
5. Disconnect gas inlet pipe from the Natural Gas
Regulator.
6. Remove the Natural Gas Regulator from the
appliance.
7. Fit the Universal LP Gas test point inlet fitting
supplied in the conversion kit.
8. Connect the gas supply to the inlet fitting.
9. Check for gas leaks. Do not use a naked flame
to check for gas leaks.
10. Adjust the gas pressure to 2.75 kPa.
11. Test the appliance on both high and low flame
for each burner and check the gas pressure. If the
burner fails to remain alight or the flame is not
stable on the simmer setting, adjust the by-pass
screw, until flame is stable.
12. If not already removed, remove the “Only for
use with Natural Gaslabel adhered to the bottom
panel near the gas connection.
13. Fit the new data label included in the gas
conversion kit.
Mod: OCG63FFX
3 Burners
Mod: OCG64FFX
4 Burners
Mod: OCG95FFX
5 Burners
Mod: OCG63FFX
3 Burners
Mod: OCG64FFX
4 Burners
Mod: OCG95FFX
5 Burners
Download manual in English (PDF, 1.24 MB)
(Consider the environment and only print this manual if it is really necessary)

Loading…

Rating

Let us know what you think about the Omega OCG64FFX Hob by leaving a product rating. Want to share your experiences with this product or ask a question? Please leave a comment at the bottom of the page.
Are you satisfied with the Omega OCG64FFX Hob?
Yes No
Be the first to rate this product
0 votes

Join the conversation about this product

Here you can share what you think about the Omega OCG64FFX Hob. If you have a question, first carefully read the manual. Requesting a manual can be done by using our contact form.

More about this manual

We understand that it’s nice to have a paper manual for your Omega OCG64FFX Hob. You can always download the manual from our website and print it yourself. If you would like to have an original manual, we recommend you contact Omega. They might be able to provide an original manual. Are you looking for the manual of your Omega OCG64FFX Hob in a different language? Choose your preferred language on our homepage and search for the model number to see if we have it available.

Specifications

Brand Omega
Model OCG64FFX
Category Hobs
File type PDF
File size 1.24 MB

All manuals for Omega Hobs
More manuals of Hobs

Frequently Asked Questions about Omega OCG64FFX Hob

Our support team searches for useful product information and answers to frequently asked questions. If you find an inaccuracy in our frequently asked questions, please let us know by using our contact form.

Which pans can be used on an induction hob? Verified

In general all pans that are magnetic can be used on an induction hob. Almost all new pans are suited for induction.

This was helpful (1380) Read more

My hob has a power plug that doesn't fit a regular socket, what should I do? Verified

Many electric hobs (both ceramic and induction) have a different plug. This is because these appliances require a lot of power. Have the installation of the appliance done by a professional.

This was helpful (1308) Read more

Why does the ignition on my range make a clicking sound? Verified

If the range has ben cleaned with a lot of water, the knobs might have gotten wet, triggering the ignition. Let the knobs dry. If the problem persists you should contact the manufacturer.

This was helpful (1118) Read more
Manual Omega OCG64FFX Hob

Related products

Related categories