Manual Mitsubishi MSZ-FT50VGK Air Conditioner

Need a manual for your Mitsubishi MSZ-FT50VGK Air Conditioner? Below you can view and download the PDF manual for free in English. This product currently has 7 frequently asked questions, 0 comments and has 0 votes. If this is not the manual you want, please contact us.

Is your product defective and the manual offers no solution? Go to a Repair Café for free repair services.

Manual

Loading…

To use this unit correctly and safely, be sure to read these operating instructions before use.
EN
EN-2
The unit should not be installed, relocated, disassembled, altered,
or repaired by the user.
An improperly handled air conditioner may cause re, electric shock,
injury, or water leakage, etc. Consult your dealer.
If the power supply cord is damaged, it must be replaced by the manu-
facturer or its service agent in order to avoid a hazard.
When installing, relocating, or servicing the unit, make sure that
no substance other than the specifi ed refrigerant (R32) enters the
refrigerant circuit.
Any presence of foreign substance such as air can cause abnormal
pressure rise and may result in explosion or injury.
The use of any refrigerant other than that specifi ed for the system will
cause mechanical failure, system malfunction, or unit breakdown. In the
worst case, this could lead to a serious impediment to securing product
safety.
This appliance is not intended for use by persons (including children)
with reduced physical, sensory or mental capabilities, or lack of ex-
perience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible
for their safety.
Children should be supervised to ensure that they do not play with
the appliance.
Do not insert your nger, a stick, or other objects into the air inlet
or outlet.
This may cause injury, since the fan inside rotates at high speeds during
operation.
In case of an abnormal condition (such as a burning smell), stop the
air conditioner and disconnect the power plug or turn the breaker OFF.
A continued operation in the abnormal state may cause a malfunction,
re, or electric shock. In this case, consult your dealer.
When the air conditioner does not cool or heat, there is a possibility of
refrigerant leakage. If any refrigerant leakage is found, stop operations
and ventilate the room well and consult your dealer immediately. If a
repair involves recharging the unit with refrigerant, ask the service
technician for details.
The refrigerant used in the air conditioner is not harmful. Normally, it
does not leak. However, if refrigerant leaks and comes in contact with
re or heating part of such a fan heater, kerosene heater, or cooking
stove, it will create harmful gas and there is risk of fi re.
The user should never attempt to wash the inside of the indoor unit.
Should the inside of the unit require cleaning, contact your dealer.
Unsuitable detergent may cause damage to plastic material inside
the unit, which may result in water leakage. Should detergent come in
contact with electrical parts or the motor, it will result in a malfunction,
smoke, or fi re.
The appliance shall be stored in a room without continuously operating
ignition sources (for example: open ames, an operating gas appliance
or an operating electric heater).
Be aware that refrigerants may not contain an odour.
Do not use means to accelerate the defrosting process or to clean the
appliance, other than those recommended by the manufacturer.
Do not pierce or burn.
The indoor unit must be installed in rooms which exceed the fl oor
space specifi ed. Please consult your dealer.
This appliance is intended to be used by expert or trained users in
shops, in light industry and on farms, or for commercial use by lay
persons.
CAUTION
Do not touch the air inlet or the aluminum fi ns of the indoor/outdoor
unit.
This may cause injury.
Do not use insecticides or fl ammable sprays on the unit.
This may cause a fi re or deformation of the unit.
Do not expose pets or houseplants to direct airfl ow.
This may cause injury to the pets or plants.
Do not place other electric appliances or furniture under the indoor/
outdoor unit.
Water may drip down from the unit, which may cause damage or
malfunction.
Do not leave the unit on a damaged installation stand.
The unit may fall and cause injury.
Do not step on an unstable bench to operate or clean the unit.
This may cause injury if you fall down.
Do not pull the power cord.
This may cause a portion of the core wire to break, which may cause
overheating or fi re.
Do not charge or disassemble the batteries, and do not throw them
into a fi re.
This may cause the batteries to leak, or cause a fi re or explosion.
SAFETY PRECAUTIONS
Do not operate the unit for more than 4 hours at high humidity (80%
RH or more) and/or with windows or outside door left open.
This may cause the water condensation in the air conditioner, which
may drip down, wetting or damaging the furniture.
The water condensation in the air conditioner may contribute to growth
of fungi, such as mold.
Do not use the unit for special purposes, such as storing food,
raising animals, growing plants, or preserving precision devices
or art objects.
This may cause deterioration of quality, or harm to animals and plants.
Do not expose combustion appliances to direct airfl ow.
This may cause incomplete combustion.
Never put batteries in your mouth for any reason to avoid accidental
ingestion.
Battery ingestion may cause choking and/or poisoning.
Before cleaning the unit, switch it OFF and disconnect the power plug
or turn the breaker OFF.
This may cause injury, since the fan inside rotates at high speeds during
operation.
When the unit will be unused for a long time, disconnect the power
plug or turn the breaker OFF.
The unit may accumulate dirt, which may cause overheating or fi re.
Replace all batteries of the remote controller with new ones of the
same type.
Using an old battery together with a new one may cause overheating,
leakage, or explosion.
If the battery uid comes in contact with your skin or clothes, wash
them thoroughly with clean water.
If the battery uid comes in contact with your eyes, wash them thoroughly
with clean water and immediately seek medical attention.
Ensure that the area is well-ventilated when the unit is operated
together with a combustion appliance.
Inadequate ventilation may cause oxygen starvation.
Turn the breaker OFF when you hear thunder and there is a possibility
of a lightning strike.
The unit may be damaged if lightning strikes.
After the air conditioner is used for several seasons, perform inspec-
tion and maintenance in addition to normal cleaning.
Dirt or dust in the unit may create an unpleasant odor, contribute to
growth of fungi, such as mold, or clog the drain passage, and cause
water to leak from the indoor unit. Consult your dealer for inspection
and maintenance, which require specialized knowledge and skills.
Do not operate switches with wet hands.
This may cause electric shock.
Do not clean the air conditioner with water or place an object that
contains water, such as a fl ower vase, on it.
This may cause fi re or electric shock.
Do not step on or place any object on the outdoor unit.
This may cause injury if you or the object falls down.
IMPORTANT
Dirty lters cause condensation in the air conditioner which will contribute to the
growth of fungi such as mold. It is therefore recommended to clean air fi lters every
2 weeks.
Before starting the operation, ensure that the horizontal vanes are in the closed posi-
tion. If operation starts when the horizontal vanes are in the open position, they may
not return to the correct position.
JG79Y791H01_01En.indd 2 2020/02/21 14:49:01
Download manual in English (PDF, 17.99 MB)
(Consider the environment and only print this manual if it is really necessary)

Loading…

Rating

Let us know what you think about the Mitsubishi MSZ-FT50VGK Air Conditioner by leaving a product rating. Want to share your experiences with this product or ask a question? Please leave a comment at the bottom of the page.
Are you satisfied with the Mitsubishi MSZ-FT50VGK Air Conditioner?
Yes No
Be the first to rate this product
0 votes

Join the conversation about this product

Here you can share what you think about the Mitsubishi MSZ-FT50VGK Air Conditioner. If you have a question, first carefully read the manual. Requesting a manual can be done by using our contact form.

More about this manual

We understand that it’s nice to have a paper manual for your Mitsubishi MSZ-FT50VGK Air Conditioner. You can always download the manual from our website and print it yourself. If you would like to have an original manual, we recommend you contact Mitsubishi. They might be able to provide an original manual. Are you looking for the manual of your Mitsubishi MSZ-FT50VGK Air Conditioner in a different language? Choose your preferred language on our homepage and search for the model number to see if we have it available.

Specifications

Brand Mitsubishi
Model MSZ-FT50VGK
Category Air Conditioners
File type PDF
File size 17.99 MB

All manuals for Mitsubishi Air Conditioners
More manuals of Air Conditioners

Frequently Asked Questions about Mitsubishi MSZ-FT50VGK Air Conditioner

Our support team searches for useful product information and answers to frequently asked questions. If you find an inaccuracy in our frequently asked questions, please let us know by using our contact form.

How often should I clean or replace the filters in my air conditioner? Verified

It's advisable to check the filters of your air conditioner 4 times a year. Dirty filters can be cleaned with the use of a vacuum cleaner or can be washed, depending on which type they are. During maintenance a professional should judge whether it is time to replace the filters.

This was helpful (2683) Read more

What does BTU stand for? Verified

BTU stands for British Thermal Unit. This is unit to indicate the capacity to cool.

This was helpful (949) Read more

Does every air conditioner also function as a dehumidifier? Verified

The cold air produced by an air conditioner often has a relatively low humidity. However, the effect is less than when using an actual dehumidifier. Some air conditioners do have a special feature to dehumidify the air.

This was helpful (706) Read more

What is R-410A? Verified

R-410A is a cooling agent that is used in appliances that cool up to 0°C, like refrigerators and air conditioners. It is the replacement of older cooling agents and does not damage the ozon layer.

This was helpful (485) Read more

What is the best place to mount the indoor unit of a split-type air conditioner? Verified

This depends on the space, but in general the following rules can be followed. Make sure that there is nothing obstructing the airflow. Make sure the location is accessible for maintenance. Mount the unit at least 2 meters from the ground.

This was helpful (350) Read more

Can I place my mobile air conditioner in a cabinet to get it out of sight? Verified

No, absolutely not. A mobile air conditioner needs space to allow airflow and air intake. In a small space the device can overheat.

This was helpful (348) Read more

Does an air conditioner have a negative influence on air quality? Verified

If the air conditioner has been properly maintained then it will have no influence on air quality. If for example a filter hasn't been replaced for a long time, or other maintenance has not been performed, than an air conditioner can produce dirty air.

This was helpful (346) Read more
Manual Mitsubishi MSZ-FT50VGK Air Conditioner

Related products

Related categories