NOTICE
Incorrect measured values can
result from unsuitable installation
location!
Do not install the THR 10 where it
would be subject to direct exposure
to sun rays.
Do not use the THR 10 in an area
prone to draughts, hot or cold air,
e.g. near a cooker, fridge, radiator,
etc.
Do not install the THR 10 in a unit
with other heat-generating devices,
e.g. a dimmer switch.
8. Installation / Electrical connection
DANGER
Danger to life from electric shock
Switch the mains fuse off.
Position a warning notice to avoid the
unit being accidentally switched back
on.
DANGER
Danger of short-circuits caused by
pulling the power cable out.
Install an external tension relief.
NOTICE
Danger of short-circuits caused by
damp if the power cable is not
inserted in the housing correctly.
Insert the power cable correctly.
Take off cover [1]. To do this, press the clip on the
lefthand side of the housing gently inwards using a
screwdriver and pull the cover off.
Fix the housing lower part [4] to the wall with two
screws (see arrow in the picture in Chapter 3.2).
Suitable mounting material is to be supplied by
the customer.
Remove the terminal cover [8] and connect the
cables to the connection terminal [6] as shown in
the wiring diagram.
If the temperature range should be limited,
separate the two pins [7] from the housing
lower part.
Fit terminal cover [8].
Locate the housing [1] onto the housing lower
part [4] such that it locks into place.
Switch the mains fuse on.
8.1 Start-up
Check that the technical data has been adhered
to, by reference to the rating plate.
Carry out a function test.
9. Limiting the temperature range
DANGER
You need to use the two pins [7] to
limit the temperature range, see
"Electrical connection" Danger to
life from electric shock when the
unit is open.
Switch the mains fuse off.
Position a warning notice to avoid the
unit being accidentally switched back
on.
Remove the rotary knob [5] with a screwdriver.
Plug both pins [7] onto the back of the rotary
knob, see picture. Temperature range: Minimum
setpoint 10° C, maximum setpoint 30° C.
Reattach the rotary knob [5]. Take note of the
location of the flattened side, to ensure correct
positioning.
10. Maintenance
The unit is maintenance-free.
11. Dismantling
DANGER
Danger to life. Unit is powered
up.
Switch the mains fuse off.
Dismantling should only be carried out by a trained
electrician.
12. Disposal
Not in domestic waste.
The unit contains in part material that can be
recycled and in part substances that should not
end up as domestic waste.
Dispose of the unit once it has reached the end
of its working life according to the regulations
valid where you are.
13. Wiring diagram
To apply operating
display [2] bridge
terminals 4 and 5.
14.
Maico Elektroapparate-Fabrik GmbH
Steinbeisstr. 20
78056 Villingen-Schwenningen
Germany
Service +49 7720 694 447
technik@maico.de
RLF.2_07.10_DSW_SM
07.10
Download manual in English (PDF, 0.19 MB)
(Consider the environment and only print this manual if it is really necessary)

Loading…

Rating

Let us know what you think about the Maico THR 10 Thermostat by leaving a product rating. Want to share your experiences with this product or ask a question? Please leave a comment at the bottom of the page.
Are you satisfied with the Maico THR 10 Thermostat?
Yes No
Be the first to rate this product
0 votes

Join the conversation about this product

Here you can share what you think about the Maico THR 10 Thermostat. If you have a question, first carefully read the manual. Requesting a manual can be done by using our contact form.

More about this manual

We understand that it’s nice to have a paper manual for your Maico THR 10 Thermostat. You can always download the manual from our website and print it yourself. If you would like to have an original manual, we recommend you contact Maico. They might be able to provide an original manual. Are you looking for the manual of your Maico THR 10 Thermostat in a different language? Choose your preferred language on our homepage and search for the model number to see if we have it available.

Specifications

Brand Maico
Model THR 10
Category Thermostats
File type PDF
File size 0.19 MB

All manuals for Maico Thermostats
More manuals of Thermostats

Frequently Asked Questions about Maico THR 10 Thermostat

Our support team searches for useful product information and answers to frequently asked questions. If you find an inaccuracy in our frequently asked questions, please let us know by using our contact form.

What is the dead zone of a thermostat? Verified

Many modern thermostats have a dead zone. If the temperature deviates less than 4°C from the set temperature, the system will not heat or cool. This so called dead zone of the thermostat prevents the system from turning on and off too often, saving energy.

This was helpful (1609) Read more

What is the best place to mount a thermostat? Verified

The best place for a thermostat is approximately 1,5 meter above the ground. Never place the thermostat nead a radiator or other heat emitting equipment or in direct sunlight. Choose a room that is used often. In most cases this is the living room.

This was helpful (1006) Read more
Manual Maico THR 10 Thermostat

Related products

Related categories