Manual Magnum S-Control Thermostat

Need a manual for your Magnum S-Control Thermostat? Below you can view and download the PDF manual for free in English. This product currently has 2 frequently asked questions, 1 comment and has 1 vote with an average product rating of 0/100. If this is not the manual you want, please contact us.

Is your product defective and the manual offers no solution? Go to a Repair Café for free repair services.

Manual

Loading…

Informations générales:
Le thermostat S-Control a été tout spécialement conçu pour les systèmes de
chauffage au sol électriques et dispose de 3 fonctions :
1. Permet de controler la température du sol grâce à sa sonde de sol externe.
2. Permet de controler la température de la pièce grâce au thermostat.
3. Permet de controler la température de la pièce grâce au thermostat et une sonde
de sol pour limiter la température du sol (facteur important pour les planchers en
bois).
La sonde de sol est comprise dans la livraison. Mettez toujours hors tension avant
le montage ou le démontage. Le branchement doit être effectué par un installateur
agréé en accord avec les dispositions réglementaires. Etudiez ces instructions avec
soin pour le montage ou pour la mise en service. Conservez ces consignes avec
soin pour toute utilisation ultérieure.
Consignes de montage destinées à l'installateur:
Assurez-vous avant le montage de la mise hors tension. Positionnez le bouton de
température (a) sur 5°C et otez-le délicatement. Retirez le cadre (e) et le capot de
protection (d) en appuyant légèrement sur les fixations (b) situées sur le dessus et
le dessous à l'aide d'un outil pointu. Branchez la sonde de sol et les câbles élec-
triques suivant le schéma de cablage (Fig.1). Positionnez le thermostat et fixez-le
avec 2 vis. Mettez le commutateur (h/i) dans la position suivante :
pour un chauffage au sol avec sonde de sol:
Position FLOOR (h)
- La sonde de sol DOIT être branchée
- ATTENTION : le potentiomètre situé sous le bouton rond (g) permet de paramétrer
la température maximum.
Pour un chauffage au sol avec thermostat d'ambiance:
Position ROOM (i)/ sonde de sol non connectée
- Dans ce cas, il n'est pas possible de paramétrer de température maximum de sol
(le potentiomètre situé sous le bouton rond n'est pas activé)
Pour un chauffage au sol avec thermostat d'ambiance et le paramétrage d'une
température maximum au sol:
Position ROOM (i)/ sonde de sol connecté :
- le potentiomètre situé sous le bouton rond (g) permet de régler la température
maximum du sol.
- le bouton rond de réglage permet de paramétrer la température de la pièce.
- La priorité se fait sur la sonde de sol par rapport au thermostat.
Replacez le cadre et le capot de protection en appuyant doucement.
Mode d'emploi :
Placez tout d'abord le bouton de température sur 5°C. Mettez sous tension après
avoir contrôlé soigneusement les consignes de montage. Dès que vous allumez le
thermostat, en appuyant sur le bouton marche/arrêt (f), la diode LED (c) s'allume
(vert). Vous pouvez alors paramétrer le thermostat.
Paramétrage avec sonde de sol:
Définissez tout d'abord une limite de température. Celle-ci peut être paramétrée
grâce au potentiomètre situé sous le bouton rond (g). Ensuite, vous paramétrez la
température de la pièce avec le bouton rond (a).
Paramétrage avec thermostat d'ambiance:
Vous pouvez paramétrer la température de la pièce avec le bouton rond (a), le
potentiomètre (g) situé sous le bouton rond est alors désactivé.
Paramétrage avec thermostat d'ambiance et limiteur (via sonde de sol) :
Définissez tout d'abord une limite de température de sol et paramétrez-la grâce au
potentiomètre (g) situé sous le bouton rond (a). Ensuite, vous paramétrez la tem-
pérature souhaitée de la pièce avec le bouton rond.
Pannes:
Si la diode verte (c) reste allumée alors que le bouton de la température est sur
40°C par exemple, cela signifie que :
1. le potentiomètre (g) est positionné sur une température trop basse. Tournez le
bouton de la température sur le niveau le plus élevé et contrôlez à nouveau si le
thermostat se met en route.
2. la sonde de sol n'est pas bien connectée ou elle est endommagée. Contrôlez tout
d'abord les branchements du capteur au thermostat, à cet effet consultez la notice
de montage.
Si celui-ci est correctement branché et que le problème persiste, prenez contact
avec le service clientèle.
Dans le cas d'un sol récemment installé, il est nécessaire d'attendre au moins 3
semaines jusqu'à ce que l'humidité due à la construction se soit évaporée.
Données techniques :
Tension d'alimentation : 230 V / 16 A
Puissance max. : 3200W
Echelle de température : 5° à 40°C
Classe : IP20
Coloris : blanc RAL 9010
Garantie : 2 ans
Marquage : CE
Consignes d'installation et notice d'utilisation du thermostat électronique de type S-Control
a
b
c
d
e
g
h
i
Fig.1
Fig.2
f
a: Bouton de réglage de tempéra-
ture
b: fixations
c: LED
d: Couvercle de protection
e: Vitre de protection
f: Bouton marche/arrêt
g: Potentiomètre
h/i: Commutateur
General information:
The S-Control is specially designed for electrical underfloor heating and it
contains 2 functions as thermostat.
1. With external floor sensor to regulate the floor temperature
2. With internal air sensor to regulate the air temperature.
3. With limitation sensor. Controlling the air temperature with the usage
of a floor sensor to limit a maximum floor temperature. (To use in combi-
nation with wooden floors where a maximum floor temperature needs to
be controlled)
The floor sensor is standard supplied. Always switch power off before
assembling or dismounting. Installation needs to be executed by an offi-
cial only and according to the local legislations.
Please study these instructions thoroughly before assembling or using the
thermostat. Keep the instructions for future reference.
Assembling / directions for installer:
Check if power has been turned off. At first turn the temperature with the
round button (a) to 5ºC and pull it off carefully. Remove the frame (e) and
protection cap (d) by pressing the pins (b) at the upper and lower side
with a blunt object. Connect the floor sensor, power and connection
cables according to the connection scheme (fig. 1). Position the thermo-
stat and secure it with 2 screws. Position the jumper in the following posi-
tion;
For underfloor heating with floor sensor:
FLOOR position (h)
- Floor temperature can be controlled by the temperature button (a)
- floor sensor MUST be connected
- NOTE; the maximum temperature can be adjusted with the potentio-
meter under the round button (g)
For floorheating using the internal air sensor:
ROOM position (i)
- Room temperature can be controlled by the main temperature button (a)
- Floor sensor is not connected
- There is no maximum floor temperature setting possible. (potentiometer
can not be activated)
For underfloor heating with Air sensor and to install a maximum
floor temperature position:
ROOM position (i) / floor sensor is connected
- Room temperature can be controlled by the main temperature button (a)
- the maximum floor temperature can be adjusted with the potentiometer
under the round button (g).
Replace the frame and protection cap by pressing it gently until it fits in
the right position.
Users manual:
Turn the temperature to 5ºC with the round button. When you have care-
fully checked the installation directions, turn on the power. When you
have turned on the thermostat with the on/of button (f), the LED (c) will
light up green. The thermostat can be installed now.
Settings with floor sensor:
First determine if you would like to install a limited temperature. This can
be installed with the potentiometer under the round button (g). After that
you can install the preferred floor temperature with the round button (a).
Settings with sensor and limitation sensor:
First determine the limit temperature and adjust it with the potentiometer
(g) under the round button (a). Afterwards the preferred floor temperature
can be adjusted.
Errors:
When there is a continues green light (c) regardless whether the
temperatureknob is set on (i.e.) 40°C, it means;
1. the potentiometer (g) is set at a too low temperature. Please turn the
meter to its maximum temperature and check the heating again.
2. the floor sensor is not installed properly or even broken. First check if
the sensor is installed properly, follow the instructions in the manual.
If the sensor is installed properly and the problem remains please contact
the helpdesk.
In case of a new floor wait at least 3 weeks before turning on the heating
until construction moisture has evaporated
Technical data:
Powersupply : 230 V / 16 Amp.
Maximum capacity : 3200 Watt
Temperature range : 5 - 40 ºC
Class : IP20
Colour : Polar/white
Warrant : 2 years
Approval : CE
Manufacturer:
C&F Technieken B.V. Tholen - The Netherlands
UK Helpdesk: 01887-822999
Installation and instructions manual for on/off thermostat Type S-Control
a
b
c
d
e
g
h
i
Pic.1
Pic.2
f
a temperature button
b unbolt pins
c LED
d protection cap
e frame
f on/off button
g potentiometer
h/i “Jumper”
Download manual in English (PDF, 0.22 MB)
(Consider the environment and only print this manual if it is really necessary)

Loading…

Rating

Let us know what you think about the Magnum S-Control Thermostat by leaving a product rating. Want to share your experiences with this product or ask a question? Please leave a comment at the bottom of the page.
Are you satisfied with the Magnum S-Control Thermostat?
Yes No
0%
100%
1 vote

Join the conversation about this product

Here you can share what you think about the Magnum S-Control Thermostat. If you have a question, first carefully read the manual. Requesting a manual can be done by using our contact form.

Stuart crompton 04-03-2019
My daughter has bought a house with wired heating in conserstory. Thermostat lit up but no heat on floor with control to max . Can you help. Ex tv eng with good knowledge. Diagram of connection. Magnum s control man stat fitted presume it used to work okay Stat is approx 50mm sguare small on.of push button and large round temp dail with red led. Your help appriated. Regards stuart 07766916187.

reply | This was helpful (0)

More about this manual

We understand that it’s nice to have a paper manual for your Magnum S-Control Thermostat. You can always download the manual from our website and print it yourself. If you would like to have an original manual, we recommend you contact Magnum. They might be able to provide an original manual. Are you looking for the manual of your Magnum S-Control Thermostat in a different language? Choose your preferred language on our homepage and search for the model number to see if we have it available.

Specifications

Brand Magnum
Model S-Control
Category Thermostats
File type PDF
File size 0.22 MB

All manuals for Magnum Thermostats
More manuals of Thermostats

Frequently Asked Questions about Magnum S-Control Thermostat

Our support team searches for useful product information and answers to frequently asked questions. If you find an inaccuracy in our frequently asked questions, please let us know by using our contact form.

What is the dead zone of a thermostat? Verified

Many modern thermostats have a dead zone. If the temperature deviates less than 4°C from the set temperature, the system will not heat or cool. This so called dead zone of the thermostat prevents the system from turning on and off too often, saving energy.

This was helpful (1588) Read more

What is the best place to mount a thermostat? Verified

The best place for a thermostat is approximately 1,5 meter above the ground. Never place the thermostat nead a radiator or other heat emitting equipment or in direct sunlight. Choose a room that is used often. In most cases this is the living room.

This was helpful (990) Read more
Manual Magnum S-Control Thermostat

Related products

Related categories