In the event of problems, contact the dealer or your
nearest After-sales Service. Once installed, packaging
waste (plastic, styrofoam parts etc.) must be stored
out of reach of children - risk of suocation. The
appliance must be disconnected from the power
supply before any installation operation - risk of
electrical shock. During installation, make sure the
appliance does not damage the power cable - risk of
re or electrical shock. Only activate the appliance
when the installation has been completed.
The electrical and gas connections must comply
with local regulation.
WARNING: Modication of the appliance and its
method of installation are essential in order to use
the appliance safely and correctly in all the additional
countries.
Use pressure regulators suitable for the gas
pressure indicated in the instruction.
The room must be equipped with an air extraction
system that expels any combustion fumes.
The room must also allow proper air circulation,
as air is needed for combustion to occur normally.
The ow of air must not be less than 2 m
3
/h per kW
of installed power.
The air circulation system may take air directly
from the outside by means of a pipe with an inner
cross section of at least 100 cm
2
; the opening must
not be vulnerable to any type of blockages.
The system can also provide the air needed for
combustion indirectly, i.e. from adjacent rooms
tted with air circulation tubes as described above.
However, these rooms must not be communal
rooms, bedrooms or rooms that may present a re
hazard.
Liquid petroleum gas sinks to the oor as it is
heavier than air. Therefore, rooms containing LPG
cylinders must also be equipped with vents to allow
gas to escape in the event of a leak. As a result LPG
cylinders, whether partially or completely full, must
not be installed or stored in rooms or storage areas
that are below ground level (cellars, etc.). It is
advisable to keep only the cylinder being used in
the room, positioned so that it is not subject to heat
produced by external sources (ovens, replaces,
stoves, etc. ) which could raise the temperature of
the cylinder above 50°C.
Carry out all cabinet cutting works before tting
the appliance in the furniture and remove all wood
chips and sawdust.
If the appliance is Not installed above an oven, a
separator panel (not included) must be installed in
the compartment under the appliance.
Should you experience diculty in turning the burners knobs, please
contact After Sales Service for replacement of the burner tap if found to be
faulty.
The openings used for the ventilation and dispersion of heat must never
be covered.
GAS CONNECTION
WARNING: Prior to installation, ensure that the
local distribution conditions (nature of gas and gas
pressure) and the adjustment of the appliance are
compatible.
Check that the pressure of the gas supply is
consistent with the values indicated in Table 1
(“Burner and nozzle specications”).
WARNING: The adjustment conditions for this
appliance are stated on the label (or data plate).
WARNING: This appliance is not connected to a
combustion products evacuation device. It shall be
installed and connected in accordance with current
installation regulations. Particular attention shall be
given to the relevant requirements regarding
ventilation.
If the appliances is connected to liquid gas, the
regulation screw must be fasted as tightly as possible.
IMPORTANT: When gas cylinder is adopted, the
gas cylinder or gas container must be properly
settled (vertical orientation).
WARNING: This operation must be performed by
a qualied technician
Use only exible or rigid metal hose for gas
connection.
Connection with a rigid pipe (copper or steel).
Connection to the gas system must be carried out in
such a way as not to place any strain of any kind on
the appliance. There is an adjustable L-shaped pipe
tting on the appliance supply ramp and this is
tted with a seal in order to prevent leaks. The seal
must always be replaced after rotating the pipe
tting (the seal is provided with the appliance). The
gas supply pipe tting is a threaded 1/2 gas
cylindrical male attachment.
Connecting a exible jointless stainless steel pipe
to a threaded attachment. The gas supply pipe
tting is a threaded 1/2 gas cylindrical male
attachment. These pipes must be installed so that
they are never longer than 2000 mm when fully
extended. Once connection has been carried out,
make sure that the exible metal pipe does not
touch any moving parts and is not compressed.
Only use pipes and seals that comply with current
National regulations.
IMPORTANT: If a stainless steel hose is used, it
must be installed so as not touch any mobile part of
the furniture (e.g. drawer). It must pass through an
area where there are no obstructions and where it is
possible to inspect it on all its length.
The appliance should be connected to the main
gas supply or to gas cylinder in compliance with the
current National regulations. Before carry out the
connection, make sure that the appliance is
compatible with the gas supply you wish to use. If
this is not the case, follow the instructions indicated
Join the conversation about this product
Here you can share what you think about the Indesit THP 642 IX/I Hob. If you have a question, first carefully read the manual. Requesting a manual can be done by using our contact form.