AUS
! Before operating your new appliance please read this
instruction booklet carefully. It contains important
information for safe use, installation and care of the
appliance.
! Please keep these operating instructions for future
reference. Pass them on to possible new owners of the
appliance.
Compliance with standards
This cooktop must be installed in accordance with
the requirements of local gas and electrical
authorities, as well as the latest published versions
of the following standards:
AS/NZS 5601 Gas Installation code
SAA Wiring Rules.
Positioning
! Keep packaging material out of the reach of children. It
can become a choking or suffocation hazard (
see
Precautions and tips
).
! The appliance must be installed by a qualified
professional according to the instructions provided.
Incorrect installation may cause harm to people and
animals or may damage property.
Kitchen Ventilation
Where the total input of all appliances exceeds 3
MJ/h for each cubic metre of the room or enclosure
volume, the space shall be ventilated by one of the
methods detailed below. For the purpose of
assessing the adequacy of ventilation, the space
that cannot be isolated by doors is the ‘volume of a
room’.
Natural ventilation direct from outside
Two permanent openings shall be provided directly
to outside. The openings shall be located to ensure
the distance between the top of the upper opening
and the ceiling of the room or enclosure, and the
distance between the bottom of the lower opening
and the floor of the room or enclosure does not
exceed 5% of the height of the room or enclosure.
The minimum free ventilation area provided by each
opening shall be calculated using the following
formula:
A = 3 × T
where
A = the minimum free ventilation area (cm
2
)
T = the total gas consumption of all appliances
(MJ/h)
The minimum vertical dimension of any free
ventilation opening shall be 6 mm.
NOTE 1
When used in this Clause, the term ‘directly
to outside’ means any one of the following options,
provided that the ventilation path is unobstructed by
building material or insulation:
(a) Directly through an outside wall (preferred
option).
(b) Through to an outside wall but offset.
(c) Into a cavity ventilated to outside.
(d) Into an under floor space ventilated to outside.
(e) Into a roof space ventilated to outside.
NOTE 2
The two openings may be combined
provided that the top and bottom of the opening
reach the limits set by this Clause.
Natural ventilation via adjacent room
Two permanent openings shall be provided in the
room or enclosure. The openings shall be located to
ensure the distance between the top of the upper
opening and the ceiling of the room or enclosure,
and the distance between the bottom of the lower
opening and the floor of the room or enclosure does
not exceed 5% of the height of the room or
enclosure.
The minimum free ventilation area provided by each
opening shall be calculated using the following
formula:
A = 6 × T
where
A = the minimum free ventilation area (cm
2
)
T = the total gas consumption of all appliances
(MJ/h)
These requirements shall apply to all subsequent
rooms until a room is ventilated to outside, in
accordance with the previous section, or the total
input of the appliances does not exceed 3 MJ/h for
each cubic metre of the total volume of the
enclosure and rooms.
The minimum vertical dimension of any free
ventilation opening shall be 6 mm.
NOTE
: :
: :
: The two openings may be combined
provided that the top and bottom of the opening
reach the limits set by this Clause.
Liquid petroleum gas sinks to the floor as it is heavier
than air. Therefore, rooms containing LPG cylinders
must also be equipped with vents to allow gas to
escape in the event of a leak. As a result LPG
cylinders, whether partially or completely full, must not
be installed or stored in rooms or storage areas that are
below ground level (cellars, etc.). It is advisable to
keep only the cylinder being used in the room,
positioned so that it is not subject to heat produced by
external sources (ovens, fireplaces, stoves, etc. ) which
could raise the temperature of the cylinder above 50°C.
Installation
Download manual in English (PDF, 0.65 MB)
(Consider the environment and only print this manual if it is really necessary)

Loading…

Rating

Let us know what you think about the Indesit PIM 640 AT (IX) NG Hob by leaving a product rating. Want to share your experiences with this product or ask a question? Please leave a comment at the bottom of the page.
Are you satisfied with the Indesit PIM 640 AT (IX) NG Hob?
Yes No
Be the first to rate this product
0 votes

Join the conversation about this product

Here you can share what you think about the Indesit PIM 640 AT (IX) NG Hob. If you have a question, first carefully read the manual. Requesting a manual can be done by using our contact form.

More about this manual

We understand that it’s nice to have a paper manual for your Indesit PIM 640 AT (IX) NG Hob. You can always download the manual from our website and print it yourself. If you would like to have an original manual, we recommend you contact Indesit. They might be able to provide an original manual. Are you looking for the manual of your Indesit PIM 640 AT (IX) NG Hob in a different language? Choose your preferred language on our homepage and search for the model number to see if we have it available.

Specifications

Brand Indesit
Model PIM 640 AT (IX) NG
Category Hobs
File type PDF
File size 0.65 MB

All manuals for Indesit Hobs
More manuals of Hobs

Frequently Asked Questions about Indesit PIM 640 AT (IX) NG Hob

Our support team searches for useful product information and answers to frequently asked questions. If you find an inaccuracy in our frequently asked questions, please let us know by using our contact form.

Which pans can be used on an induction hob? Verified

In general all pans that are magnetic can be used on an induction hob. Almost all new pans are suited for induction.

This was helpful (1364) Read more

My hob has a power plug that doesn't fit a regular socket, what should I do? Verified

Many electric hobs (both ceramic and induction) have a different plug. This is because these appliances require a lot of power. Have the installation of the appliance done by a professional.

This was helpful (1284) Read more

Why does the ignition on my range make a clicking sound? Verified

If the range has ben cleaned with a lot of water, the knobs might have gotten wet, triggering the ignition. Let the knobs dry. If the problem persists you should contact the manufacturer.

This was helpful (1090) Read more
Manual Indesit PIM 640 AT (IX) NG Hob

Related products

Related categories