Manual Holmes HAP1702-NTU-1 Air Purifier

Need a manual for your Holmes HAP1702-NTU-1 Air Purifier? Below you can view and download the PDF manual for free in English. This product currently has 1 frequently asked question, 0 comments and has 0 votes. If this is not the manual you want, please contact us.

Is your product defective and the manual offers no solution? Go to a Repair Café for free repair services.

Manual

Loading…

IMPORTANT SAFEGUARDS
FEATURES
may switch to a different fan/filtration speed for optimal
filtration. An automatic adjustment in speed does not
demonstrate that the air has been cleaned but does
demonstrate that air quality has been determined and an
optimal speed has been selected. The Air Quality Sensor
may adjust fan/filtration speeds at varying rates as it
continues to measure air quality during use.
FILTER CHECK INDICATOR
Your Holmes
®
Air Purifier includes Aer1
®
Allergen
Performance Plus Filters, specially designed to improve air
quality for allergy sufferers!! The Aer1
®
Allergen
Performance Plus filter last for 12 months. See back panel
for other filter options.
The Filter Check Indicator light is designed to remind you
to check and change your filters every 11 months. To reset
the Filter Check Indicator, press and hold the Filter Reset
Button for 3 seconds only under working mode.
BEFORE USE
1. Carefully unpack your Air Purifier. Select a firm level
place where there are no obstructions to the air inlet
or filtered air outlet.
2. Remove the air inlet grill and check if the filter is
covered by a plastic bag. If it is, remove plastic bag
before use.
3. The carbon filters are packed in a plastic bag in the
box. Remove plastic bag, use the provided Velcro to
attach the carbon filters onto the Aer1
®
filters. Then,
place all filters back into the unit, and reinstall the air
inlet grill (see Fig. 1).
4. DO NOT POINT FILTERED AIR OUTLET TOWARDS WALL.
OPERATING INSTRUCTIONS
Plug into a 120V AC electrical outlet.
Power/Mode
1. Press the /Mode button to start operations, the air
purifier is default to run at LOW ( ).
2. Continue to press the /Mode button to cycle
through all speed settings/mode:
LOW ( ) - MEDIUM ( ) - HIGH ( ) – AQS
Select the appropriate setting and the corresponding
indicator light will illuminate to indicate which mode is
activated. See below section for details of Air Quality
Sensor Mode (AQS).
NOTE: For optimum air filtration, it is recommended
to operate the air purifier continuously. Its rugged
motor has been designed to give many years of use.
3. To release negative ions into the filtered air, press the
ionizer button ( ) to ON and the button will
illuminate in blue.
NOTE: The ionizer will not work unless the unit is
running.
Air Quality Sensor Mode ( )
The AQS feature uses the particle sensor to cycle between
low, medium and high speeds, based on surrounding
indoor air quality. To activate AQS mode, press the /
Mode button to select AQS and the AQS indicator light will
POWER CORD INSTRUCTIONS
The length of cord used on this appliance was selected
to reduce tangling or tripping hazards.
If a longer cord is necessary, an approved extension
cord may be used. The electrical rating of the
extension cord must be equal to or greater than the
electrical rating of the air purifier (see rating label
marked on bottom of the product).
Care must be taken to arrange the extension cord so
that it will not drape over the countertop or tabletop
where it can be pulled on by children or accidentally
tripped over.
GET TO KNOW YOUR AIR PURIFIER
This unit is compatible with all Aer1
®
Filters. This allows
you to choose the filter that is just right for you. Below is
information on each filter:
TOTAL AIR - Advanced Dust Eliminating Technology
ODOR ELIMINATOR - 10x the odor fighting power
ALLERGEN REMOVER - True HEPA technology improves
air quality for allergy sufferers
ALLERGEN PERFORMANCE PLUS - True HEPA
technology improves air quality for allergy sufferers.
SMOKE GRABBER - 99% effective at removing smoke
from the air steam (*as small as 0.3 microns from air
passing through the filter)
IONIZER
This appliance has an optional ionizer feature which, when
turned on, releases negative ions into outgoing filtered air
to help the air purification process.
What Are Ions?
Ions are tiny particles that carry a positive or negative
charge. They exist naturally around us: in the air, water,
and ground. Both positive and negative ions are colorless,
odorless, and harmless.
How Does The Ionizer Work?
Negative ions help air purification by attaching themselves
to very small airborne particles in the room. These
particles take on a negative charge and may join with
positively charged particles such as dust, pollen, smoke,
and pet dander to form larger particles. These larger
particles are then more easily captured by the filter
system.
Important Notes:
Your ionizer may produce an occasional popping or
cracking sound. This is normal and occurs when a small
buildup of ions is discharged.
After extended use, you may notice dust around the grills
or front panel. This is caused by negative ions exiting the
air outlet, evidence of the ionizer’s air cleaning
effectiveness. You can remove the dust with a soft brush or
clean, damp cloth.
Larger particles may be attracted to positively charged
surfaces throughout the home, like walls or floors.
This may occur more frequently when the filter is
nearing the end of its useful product life and unable to
capture as many charged particles.
Excessive amounts of pet dander, dust, or smoke may
decrease the life expectancy of the filter and interfere
with the ionization process.
To help prevent particles from attracting to surfaces
throughout your home:
You may want to run the ionizer less often.
Check the condition of the filter more frequently.
CAUTION: The ionizer in this appliance produces less
ozone than the UL established limits of 50ppb. However, in
high concentrations, ozone can be harmful to birds and
small pets. To prevent ozone buildup, we suggest using the
ionizer in well ventilated areas with the air purifier fan on.
HIGH, MEDIUM AND LOW SPEED
SETTINGS
For optimum air filtration, operate your Holmes
®
air
purifier continuously on the MEDIUM ( ) setting. Its
rugged motor has been designed to give many years of
use. For quieter operation (such as in a bedroom), select
the LOW ( ) setting. When high levels of air pollution
are present, select the HIGH ( ) setting to quickly
circulate and filter the room air.
AIR QUALITY SENSOR
Your Air Purifier is equipped with Air Quality Sensor to
cycle between low, medium and high speeds, based on
surrounding indoor air quality. Press Power /Mode
button to select AQS setting, the air purifier will run on
High upon startup in order to quickly analyze surrounding
air quality. Once air quality has been determined, the unit
When using electrical appliances, basic safety precautions
should always be followed to reduce the risk of fire, electric
shock, and injury to persons. These precautions include:
1. Read all instructions before using the appliance.
2. To avoid fire or shock hazard, plug the appliance
directly into a 120V AC electrical outlet.
3. If the filter is covered by a bag when shipped,
remove plastic bag before use.
4. Keep the cord out of heavy traffic areas. To avoid
fire hazard, NEVER put the cord under rugs, near
heat registers, radiators, stoves, or heaters.
5. To protect against electrical hazards, DO NOT
immerse the appliance in water or other liquids. Do
not use near water.
6. Close supervision is necessary when any appliance is
used by or near children, or disabled persons.
7. Always unplug the air purifier before moving or
cleaning the unit, opening the grill, changing the filters
and whenever the unit is not in use. To disconnect the
unit, be sure to pull the plug and not the cord.
8. NEVER drop or insert any objects into the openings of
the unit.
9. DO NOT operate any appliance with a damaged cord
or plug. If the motor fan fails to operate or the unit
has been dropped or damaged in any manner, return
appliance to manufacturer for examination and/or
repair.
10. Use appliance only for intended household use as
described in this manual. Any other use not
recommended by the manufacturer may cause fire,
electric shock, or injury to persons. The use of
attachments not recommended or sold by Jarden
Consumer Solutions may cause injury.
11. DO NOT use outdoors.
12. NEVER place on a soft surface such as a bed or sofa
as this could cause the unit to tip over and block the
air inlet or outlet grills.
13.
Keep unit away from heated surfaces and open flames.
14. DO NOT attempt to repair or adjust any electrical or
mechanical functions on this unit. Doing so may
cause injury and will void your warranty. The inside
of the unit contains no user serviceable parts. All
servicing should be performed by Jarden Consumer
Solutions or an authorized Jarden Consumer
Solutions Center.
15. DO NOT place anything on top of unit.
16. NEVER use detergents, gasoline, glass purifier,
furniture polish, paint thinner, or other household
solvents to clean any part of the appliance.
17. Always turn the appliance off before unplugging it.
18. The ionizer may cause a static charge to build up on
the air outlet grill. A static charge may be felt if the
unit is not properly grounded. To avoid a static
charge, plug the unit's three-prong plug into a
grounded outlet. The static charge will not occur if
the ionizer is off.
19.
The ionizer in this appliance produces less ozone than
the UL established limits of 50ppb (parts per billion).
However, in high concentrations, ozone can be harmful
to birds and small pets. To prevent ozone buildup, we
suggest using the ionizer in well ventilated areas with
the fan on.
20. This appliance should only be used in a room with
temperatures between 40° F and 110° F.
21. To reduce the risk of fire or electric shock, DO NOT
use this appliance with any solid-state speed control
device.
SAVE THESE
INSTRUCTIONS
FEATURES - OPERATIONS
CLEANING/MAINTENANCE
FILTER REPLACEMENT
illuminate in RED (default) and the unit will run at HIGH
setting. The AQS indicator light will change in 3 colors to
indicate different indoor air quality conditions, and the
speed setting will be changed automatically based on the
current indoor air quality:
REDPoor air quality: The unit will run at HIGH setting
to improve air quality
YELLOWAverage air quality: The unit will run at
MEDIUM setting to maintain air quality
GREENGood air quality: The unit will run at LOW
setting to achieve energy saving.
NOTE: When AQS mode is activated, only the AQS
indicator light will illuminate, all the other speed setting
indicator lights (Hi/Med/Lo) will go off under AQS mode.
Timer
You may set the timer so it automatically turns off when
the desired time has elapsed:
1. Press the TIMER ( ) button to select the desired
number of hours you want the unit to operate (2Hr,
4Hr, 6Hr or 8Hr):
The corresponding indicator light will illuminate to
indicate which timer option is selected.
When the air purifier is running up to the set time, the
air purifier will turn off automatically.
2. To CANCEL the timer, press the TIMER button until
TIMER indicator lights go off.
CLEANING/MAINTENANCE INSTRUCTIONS
1. Turn the air purifier off and unplug it before cleaning.
2. The outside of the air purifier can be cleaned with a
soft, clean dampened cloth.
3. The air inlet grill (reference Fig. 1) can be removed
and washed in warm soapy water (not dishwasher
safe). Dry before replacing in the unit.
4. The filtered air outlet can be cleaned of dust with a
small, soft brush.
5. If you wish to clean the inside of the air purifier,
please only use a dry, soft cloth to wipe it down.
WARNING: Do not allow moisture to come in contact
with the main housing of the air purifier.
FILTER REPLACEMENT INSTRUCTIONS
IMPORTANT:
DO NOT attempt to wash and re-use the Aer1
®
Filters.
If the filters are enclosed in plastic bags, remove them
before use.
NOTE:
Every few weeks, check the condition of filters. Filter life
will vary, depending on air quality and usage (see below).
Under normal conditions of continuous use, the Aer1
®
Total Air, Odor and Smoke Filter will last 4 months while
the Allergen and Allergen Performance Plus Filter will last
12 months. Check the condition of the Carbon Filters for
every 3-4 months and replace if needed. Carbon filters
need to be replaced every 60-90 days.
After approximately 11 months of operation, the Filter
Check Indicator will light up to alert you to service the filters.
This Filter Check indicator is to remind you to wash the
foam pre-filter and replace your Aer1
®
Filters and
carbon filters.
Filters can be purchased at a retailer near you, online at www.aer1filters.com, or by calling (855) Try-aer1.
Air Purifier
Model Number
Filter Quantity
Needed
Compatible with all
filter models below
Filter Description
HAP1702
2
HAPF30AT
HAPF30AO
HAPF30AS
HAPF300AH
HAPF300AP (D filter)
HAPF30 (A filter)
aer1
®
Total Air Filter
aer1
®
Odor Filter
aer1
®
Smoke Grabber Filter
aer1
®
Allergen Remover Filter
aer1
®
Allergen Performance Plus "D" Filter
Holmes
®
"A" Filter
2 AOR31 Carbon Filter
To reduce the risk of electric shock, this equipment has a grounding type plug that has a third (grounding) pin.
This plug will only fit into a grounding type power outlet. If the plug does not fit into the outlet, contact qualified
personnel to install the proper outlet. Do not alter the plug in any way.
THIS PRODUCT IS EQUIPPED WITH A 3-PRONG PLUG
Fig. 1
A. Speed Setting
Indicator Lights
B. Power/Mode Button
C. Filter Reset
Button/Light
D. Timer Button
E. Timer Indicator lights
F. Ionizer Button/Light
G. AQS Indicator Light
H. Filtered Air Outlet
I. Aer1
®
Filters
J. Carbon Filters
K. Washable Foam
Pre-Filter
L. Air Inlet Grill
H
K
J
J
L
I
I
C
B
D
F
A
E
G
HAP1702-NTU_16EM2.indd 2 9/26/16 9:41 AM
Download manual in English (PDF, 1.61 MB)
(Consider the environment and only print this manual if it is really necessary)

Loading…

Rating

Let us know what you think about the Holmes HAP1702-NTU-1 Air Purifier by leaving a product rating. Want to share your experiences with this product or ask a question? Please leave a comment at the bottom of the page.
Are you satisfied with the Holmes HAP1702-NTU-1 Air Purifier?
Yes No
Be the first to rate this product
0 votes

Join the conversation about this product

Here you can share what you think about the Holmes HAP1702-NTU-1 Air Purifier. If you have a question, first carefully read the manual. Requesting a manual can be done by using our contact form.

More about this manual

We understand that it’s nice to have a paper manual for your Holmes HAP1702-NTU-1 Air Purifier. You can always download the manual from our website and print it yourself. If you would like to have an original manual, we recommend you contact Holmes. They might be able to provide an original manual. Are you looking for the manual of your Holmes HAP1702-NTU-1 Air Purifier in a different language? Choose your preferred language on our homepage and search for the model number to see if we have it available.

Specifications

Brand Holmes
Model HAP1702-NTU-1
Category Air Purifiers
File type PDF
File size 1.61 MB

All manuals for Holmes Air Purifiers
More manuals of Air Purifiers

Frequently Asked Questions about Holmes HAP1702-NTU-1 Air Purifier

Our support team searches for useful product information and answers to frequently asked questions. If you find an inaccuracy in our frequently asked questions, please let us know by using our contact form.

Does an air purifier also remove regular dust from the air? Verified

Yes, air purifiers also remove dust from the air that otherwise would need to be removed by dusting and cleaning. It depends on the air purifier up to what size of dust can be removed from the air.

This was helpful (158) Read more
Manual Holmes HAP1702-NTU-1 Air Purifier

Related products

Related categories