Do not use hot water above 40°C for cleaning the pre- lter.
Do not operate the air conditioner without the pre- lter.
CAUTION
!
Never use hot water above 50°C, erosive chemicals or brush to clean the front cover and suction grille because they
will damage the plastic surface.
!
CAUTIONS
The installation material must be corrosion proof, especially the air conditioner is installed near the sea or hot spring.
Do not install air conditioner in the places where there is a possibility of in ammable gas leaks.
Secure tightly the cabinet with screws to the frame. Otherwise there may be danger of the air conditioner dropping.
Please keep the recommended installation dimensions. Otherwise waterdrops or malfunction may occur.
!
CAUTIONS
POWER SOURCE
Check the capacity of wiring and power outlet. The power outlet should be used exclusively for the air conditioner. Do
not use it with other appliances. Any wiring must follow the national wiring regulation.
Ground the air conditioner to prevent danger of electric shock.
Connect the air conditioner with power source securely.
Use a fuse as below:
RA-08LDF
RA-10LDF
RA-13LDF
Voltage rating
Operatable
Voltage range
50Hz 220V
15A time delay fuse
50Hz 198-242V
This appliance must be earth
CAUTION
!
SLIDE OUT OF UNIT
After slide in the unit, please install a sealer between
the base pan and cabinet to prevent from entering rain
water in case of typhoon. Fasten the unit to cabinet
at the side with the screw, then re t the front cover.
1
Remove the four screws which fasten the base pan
to the cabinet at the side and back.
2
Remove the stopper at front left side of base. (RA-13LDF)
3
Slide out the unit by pulling the handles.
DRAIN PAN
Drain Pan edge shall not exceed the cabinet roller.
!
CAUTIONS
7RS9LHZ
INSTALLATION WORK INSPECTION CHECK LIST
CAUTION
When using the operation of auto swing function, Please manually turn the vertical de ector to the utmost right angle before switching
on the auto swing function.
An abnormal sound will occur when adjusting the vertical de ector before switching on the auto swing. This abnormality does not affect
the operation.
It there is any abnormalities in the vertical movement during the auto swing operation, please do the above setting again.
When raining, rain water will enter the outdoor side. An abnormal sound will occur during operation of unit in raining conditions and
approximately 10 minutes after rain stop. This will not affect the performance or liability of the room air conditioner.
MEMO
.....................................................................................................................................................................................................
.....................................................................................................................................................................................................
.....................................................................................................................................................................................................
Model
RA-08LDF
RA-10LDF
RA-13LDF
a
365
395
* Recommended dimension for performance testing purpose only.
b
490
580
c
Over 200
Over 200
d
Over
100
e
Over
1200
f
Over
150
g
Over
900
h
Over
200
i
Over
200
j*
130 or more
160 or more
Dimension (mm)
Recommended temperature range for safety testing should be as below:
Cold side : Dry bulb 21 – 32°C
Wet bulb 15 – 23°C
Hot side : Dry bulb 21 – 43°C
Wet bulb 15 – 26°C
<
IA890: B
>
Always turn off and unplug the unit before any cleaning or maintenance to ensure safety
CAUTION
!
PRE-FILTER
If the pre- lter is clogged with dust, the air ow volume will be decreased and resulting in poor cooling performance, and
increased operating noise. Be sure to clean the lter about every 20 days.
1 Remove the suction grille by pulling the bottom corner and slightly lift up the
suction grille.
2 - 3 Pull downward to unhook the suction grille and remove the suction grille.
Lift and unhook the bottom of the pre- lter and remove it.
Remove dust from the pre- lter by using a vacuum cleaner. If the pre- lter
is very dirty, wash it with detergent and rinse properly with water. Dry
the pre- lter with soft cloth and do not expose it to heat or under direct
sunlight.
Install the pre- lter by tting the top hooks and then hook the bottom of
the pre- lter.
Attach the suction grille back to its place by hooking at the top side to
the front cover, then gently push at bottom corner.
Clean the front cover and suction grille with a soft dry cloth. When it is excessively dirty, wipe it with a soft cloth dampened
with mild soap, then wipe it again thoroughly with a soft dry cloth.
The suction grille can also be removed and be washed with water and mild soap. Remove the suction grille in the
following manner.
1 Remove the suction grille by pulling the bottom corner
and slightly lift up the suction grille .
2 - 3 Pull downward to unhook the suction grille and remove
the suction grille.
Does not operate at all
Poor cooling performance
Check the following items before asking for service. If the malfunction persists, please contact service centre.
1
Is the power cord loosened or unplugged?
2
Is the fuse blown out or the circuit breaker tripped?
3
Is the voltage normal?
4
Is the main switch set to “OFF” position?
1
Is the pre- lter covered with heavy dust?
Clean pre- lter and replace it.
2
Is the temperature setting correctly?
3
Is the sunlight fall directly in the air conditioner?
4
Is the air ow on the rear side (outdoor) blocked?
Leave a space of 900 mm (3 feet) behind the rear side of air conditioner.
5
The doors or windows may be opened widely or there are other sources of heat in
the room.
6
Is the ventilation damper opened?
Symptom Check
If the power supply cord is damaged, it must be replaced by the manufacturer, its service agent or similiarly quali ed
persons in order to avoid a hazard.
CAUTION
!
Remove all the shipping parts before installation and consult an authorised dealer concerning installation requirements,
otherwise may damage the air conditioner.
LOCATION
Select a location that can support the weight of the air conditioner and will not cause increased operating noise and
vibration.
Select a location to avoid direct sunlight on the air conditioner.
Select a good location for ef cient air circulation.
Select a location where there is no obstacles near the air inlet and outlet.
INSTALLATION INSTRUCTIONS
REMOVE THE FRONT COVER
1
Remove the rubber plug from the base pan.
2
Install the drain pan by using 2 pieces of screws (provided) at the cabinet.
3
Connect the drain pan with the drain hose to drain point. (Drain hose or tubing
can be purchase locally. Drain hose inner diameter should be around ø13mm
or 1/2 inch.)
4 Pour 2 glasses of water into the drain pan to ensure the drainage is functioning
normal.
5
Slide the air conditioner unit back into the cabinet.
CONDENSED WATER DRAINAGE
This air conditioner use a “turbo fan splashing ring” which is designed to splash the condensated water on the condenser
surface for maximum cooling ef ciency, thus producing a splashing sound.
If you are uncomfortable with the sound, you can install an outside drainage by using
the following procedure which may, reduce the cooling operation performance.
Have you removed the shipping parts? Please check the caution sheet which is
attached at front cover.
Is the incline of room air conditioner regarding front and rear, right and left all right
after installation?
Is the strength of installation suf cient?
Have you grounded the room air conditioner?
Have you fastened the unit to the cabinet?
Have you done a test operation, and are there any abnormal phenomena?
Item
No.
1
2
3
4
5
6
Check Item Con rm
MAINTENANCE
BEFORE ASKING FOR SERVICE
FRONT COVER AND SUCTION GRILLE
Remove the front cover in the following manner.
1 Remove the suction grille by pulling the bottom corner and
slightly lift up the suction grille.
2 - 3 Pull downward to unhook the suction grille and remove
the suction grille.
4 Lift and unhook the bottom of the pre- lter and remove it.
5 Remove two screws which secure the front cover.
6 Remove the front cover from lower side. Disconnect the
timing motor connector at right side of the electrical box.
The Drain Pan can be used in any positions as below and be secured by 2 screws to avoid water dropping problem:
POWER CORD ARRANGEMENT
If power cord is withdrawn from left side of unit, please
arrange the power cord as in gure after installing the
front cover.
20mm or more 20mm or more
INS RA-08-10-13LDF 2INS RA-08-10-13LDF 2 7/3/12 7:19 PM7/3/12 7:19 PM
Download manual in English (PDF, 1.64 MB)
(Consider the environment and only print this manual if it is really necessary)

Loading…

Rating

Let us know what you think about the Hitachi RA-10LDF Air Conditioner by leaving a product rating. Want to share your experiences with this product or ask a question? Please leave a comment at the bottom of the page.
Are you satisfied with the Hitachi RA-10LDF Air Conditioner?
Yes No
Be the first to rate this product
0 votes

Join the conversation about this product

Here you can share what you think about the Hitachi RA-10LDF Air Conditioner. If you have a question, first carefully read the manual. Requesting a manual can be done by using our contact form.

More about this manual

We understand that it’s nice to have a paper manual for your Hitachi RA-10LDF Air Conditioner. You can always download the manual from our website and print it yourself. If you would like to have an original manual, we recommend you contact Hitachi. They might be able to provide an original manual. Are you looking for the manual of your Hitachi RA-10LDF Air Conditioner in a different language? Choose your preferred language on our homepage and search for the model number to see if we have it available.

Specifications

Brand Hitachi
Model RA-10LDF
Category Air Conditioners
File type PDF
File size 1.64 MB

All manuals for Hitachi Air Conditioners
More manuals of Air Conditioners

Frequently Asked Questions about Hitachi RA-10LDF Air Conditioner

Our support team searches for useful product information and answers to frequently asked questions. If you find an inaccuracy in our frequently asked questions, please let us know by using our contact form.

How often should I clean or replace the filters in my air conditioner? Verified

It's advisable to check the filters of your air conditioner 4 times a year. Dirty filters can be cleaned with the use of a vacuum cleaner or can be washed, depending on which type they are. During maintenance a professional should judge whether it is time to replace the filters.

This was helpful (2677) Read more

What does BTU stand for? Verified

BTU stands for British Thermal Unit. This is unit to indicate the capacity to cool.

This was helpful (945) Read more

Does every air conditioner also function as a dehumidifier? Verified

The cold air produced by an air conditioner often has a relatively low humidity. However, the effect is less than when using an actual dehumidifier. Some air conditioners do have a special feature to dehumidify the air.

This was helpful (702) Read more

What is R-410A? Verified

R-410A is a cooling agent that is used in appliances that cool up to 0°C, like refrigerators and air conditioners. It is the replacement of older cooling agents and does not damage the ozon layer.

This was helpful (479) Read more

What is the best place to mount the indoor unit of a split-type air conditioner? Verified

This depends on the space, but in general the following rules can be followed. Make sure that there is nothing obstructing the airflow. Make sure the location is accessible for maintenance. Mount the unit at least 2 meters from the ground.

This was helpful (346) Read more

Can I place my mobile air conditioner in a cabinet to get it out of sight? Verified

No, absolutely not. A mobile air conditioner needs space to allow airflow and air intake. In a small space the device can overheat.

This was helpful (345) Read more

Does an air conditioner have a negative influence on air quality? Verified

If the air conditioner has been properly maintained then it will have no influence on air quality. If for example a filter hasn't been replaced for a long time, or other maintenance has not been performed, than an air conditioner can produce dirty air.

This was helpful (341) Read more

Why is the filter light on my (N6 Series) indoor unit on? Verified

When the machine has functioned for over 100 hours this light will burn to indicate the filters need cleaning. Clean the filter and put it back. The light will stop burning when you press "Auto Swing" on the remote control while the device is turned off (standby mode).

This was helpful (59) Read more