The Halstead Ace HE24, HE30 and HE35 are high efficiency condensing,
fully automatic, wall mounted gas appliances for use with natural gas.
The appliances incorporate a microprocessor based, fully modulating pre-mix gas
control system with direct burner ignition.
The Ace HE24 provides central heating at outputs between 6.0 kW (20,500
Btu/h) and 18.0 kW (61,500 Btu/h) and domestic hot water at outputs between
6.0 kW (20,500 Btu/h) and 24.0 kW (82,000 Btu/h).
The Ace HE30 provides central heating at outputs between 7.2 kW (24,600
Btu/h) and 23.1 kW (78,900 Btu/h) and domestic hot water at outputs between
7.2 kW (24,600 Btu/h) and 30.0 kW (102,400 Btu/h).
The Ace HE35 provides central heating at outputs between 8.3 kW (28,300
Btu/h) and 24 kW (81,900 Btu/h) and domestic hot water at outputs between
8.3 kW (28,300 Btu/h) and 35 kW (119,400 Btu/h).
Heat output is controlled according to demand (in both domestic hot water and
central heating modes) by the fully modulating pre-mix burner control. The
appliance always gives priority to domestic hot water supply. The appliance
incorporates frost protection. However this is not operational when the main
electrical supply to the appliance is isolated. An electro/mechanical 24hr time
clock is fitted as standard.
Gas Consumer Council: The Gas Consumer Council (GCC) is an
independent organization which protects the interests of gas users. If you need
advice, you will find the telephone number in your local directory under 'Gas'.
2
SAFETY
Read these instructions and the user label (fitted on the boiler front panel)
carefully before attempting to operate the appliance. Comply with all
applicable warnings.
Do not interfere with any sealed components
and use the appliance only in accordance with these instructions.
CURRENT GAS SAFETY (INSTALLATION AND
USE) REGULATIONS OR THE RULES IN FORCE.
It is the law that all gas appliances are installed by a competent person in
accordance with the above regulations. Failure to install appliances
correctly could lead to prosecution. It is in your own interest, and that of
safety, to ensure that the law is complied with. If the appliance is
damaged, turn off the appliance and consult a CORGI registered installer.
If it is known or suspected that a fault exists on the appliance it MUST
NOT be used until the fault has been rectified by a competent person.
2.2
ELECTRICAL SUPPLY
This appliance must be earthed.
Supply: 230V - 50Hz fused at 3A.
The method of connection to the mains supply must facilitate complete
isolation of the appliance. Either a 3A fused three pin plug and
unswitched shuttered socket outlet, or a 3A fused double pole switch
having a 3 mm contact separation in both poles, serving only the boiler
(and its external controls), may be used.
2.3
CLEARANCES AND VENTILATION
It is not necessary to have a purpose provided air vent in the room or
internal space in which a room-sealed appliance is installed. Cupboard or
compartment ventilation is not necessary for a room-sealed appliance
providing that the minimum clearances are maintained.
Where an open flued (B23) system is used (for example KIT E 'Chimney
flue liner kit') then an air vent must be provided in the same room or
internal space as the flue duct air inlet with a minimum free-area as stated
in section 3.4 of the boilers installation manual.
4
HOT WATER OPERATION
On a demand for DHW, water flow is detected and the ignition sequence
initiated. The fan and pump will start and the boiler will light.
If the DHW draw off rate is high (over 10l/min.), the appliance will run
continuously at full output until the tap is either turned off, or the flow rate is
reduced, in which case the heat supplied will reduce accordingly to
maintain a steady temperature (55°C max).
Hot water is made available at the appliance outlet almost immediately, but
the final temperature and time taken for the hot water to reach a tap
depends upon the rate at which water is drawn off and the length of the
pipe runs between the boiler and taps.
When the tap is turned off, the appliance after a short period of time will
revert to heating mode if there is a demand. Otherwise the burner will be
extinguished until the next demand for hot water.
1
INTRODUCTION
3
BOILER LOGBOOK
Please ensure that you have a Logbook supplied with your appliance. This
Logbook should be completed by your installer to verify that the correct
installation and commissioning procedure was followed.
Failure to complete the Logbook may result in difficulties should a problem
arise with your appliance during the guarantee period.
This Logbook forms part of the industry's Benchmark code of practice for the
installation, commissioning and servicing of central heating systems. All
CORGI Registered Installers carry a CORGI ID card and have a registration
number. Both should be recorded in your Logbook. You can check your
installer is CORGI registered by calling CORGI on 0870 401 2230.
2.1
5
OPERATING INSTRUCTIONS
Refer to Fig. 1
1) Switch on the electrical supply.
If heating is required, ensure that the clock is set to an ON period (see
diagram) or set the clock over-ride switch to the ON position. Turn up the
room thermostat (if fitted).
2) Turn the control knob to the midpoint between minimum and maximum
setting. The digital display changes from '
o
' to '
c
'.
3) When the burner has lit the digital display changes to '
C
' to indicate heating
ON and a small dot will appear in the bottom right corner of the display.
4) Hot water will be supplied as soon as any Domestic Hot Water tap is
turned on and the digital display will change to '
H
' to indicate hot water is
being supplied. A small dot will appear in the bottom right corner of the
display.
5) If the burner fails to light the fan will stop. Initially this may be due to air in
the gas supply. The boiler will automatically have five attempts at ignition.
After the five attempts it may be necessary to RESET the boiler by turning
the control knob fully anti-clockwise to the RESET position and repeat from
step 3.
6) If the digital display reads ‘ ’ it is an indication that the heating or hot
water mode is satisfied, and the boiler is performing a pump over-run
function. This is perfectly normal.
After a hot water draw off the burner may stay on for
a few seconds (see clause 5.8 'Keep hot facility' in
the installation manual)
Priority is always given to Domestic Hot Water supply.
TO LIGHT THE BOILER IN CENTRAL
HEATING MODE
5.1
Download manual in English (PDF, 0.85 MB)
(Consider the environment and only print this manual if it is really necessary)

Loading…

Rating

Let us know what you think about the Halstead Ace HE 30 Central Heating Boiler by leaving a product rating. Want to share your experiences with this product or ask a question? Please leave a comment at the bottom of the page.
Are you satisfied with the Halstead Ace HE 30 Central Heating Boiler?
Yes No
Be the first to rate this product
0 votes

Join the conversation about this product

Here you can share what you think about the Halstead Ace HE 30 Central Heating Boiler. If you have a question, first carefully read the manual. Requesting a manual can be done by using our contact form.

More about this manual

We understand that it’s nice to have a paper manual for your Halstead Ace HE 30 Central Heating Boiler. You can always download the manual from our website and print it yourself. If you would like to have an original manual, we recommend you contact Halstead. They might be able to provide an original manual. Are you looking for the manual of your Halstead Ace HE 30 Central Heating Boiler in a different language? Choose your preferred language on our homepage and search for the model number to see if we have it available.

Specifications

Brand Halstead
Model Ace HE 30
Category Central Heating Boilers
File type PDF
File size 0.85 MB

All manuals for Halstead Central Heating Boilers
More manuals of Central Heating Boilers

Frequently Asked Questions about Halstead Ace HE 30 Central Heating Boiler

Our support team searches for useful product information and answers to frequently asked questions. If you find an inaccuracy in our frequently asked questions, please let us know by using our contact form.

What is the best pressure for my central heating boiler? Verified

The right pressure is between 1 and 1,5 bar. Never let the pressure rise above 2 bar.

This was helpful (508) Read more

The piping and radiators make noise. What is causing this? Verified

There is probably air in the heating system. It's best to purge the air from the system.

This was helpful (275) Read more