6 49-5000492 Rev. 0
Using the Air Conditioner - Features
USING THE AIR CONDITIONER
Additional Features
The “Cool” circuit has an automatic 3 minute delayed
start if the unit is turned off and on quickly. This prevents
overheating of the compressor and possible circuit breaker
tripping. The fan will continue to run during this time.
There is a 2 second delay for the compressor to stop when
selecting FAN ONLY/HEAT. This is to cover the possibility
of having to roll through to select another mode.
The control will maintain the set temperature within 1°F
between 62°F and 86°F in cool or heat mode (on some
models).
After a power outage, the unit will remember last setting
and return the unit to that setting when power is restore.
Air Direction
Air directional louvers control air flow direction.
The louvers will allow you to direct the air flow up or down
and left or right throughout the room as needed until the
desired left/right direction is obtained. Pivot horizontal
louvers until the desired up/down direction is obtained.
Ventilation
To open the ventilation port, remove the adjustable air discharge louvers by gently pulling forward the right end until
it is released from the pivot point. Shift the louvers to the right to release the left end from its pivot point. To open the
ventilation port, pull the lever forward. The lever will lock in place. To replace the air discharge louvers, reverse the
above procedure
Remote Wall Thermostat (Heat/Cool models only)
All heat/cool models are capable of being controlled by a
24 VAC remote wall thermostat. The thermostat control
connection board is located behind a metal cover on the
right side of the metal chassis cover. To open the cover,
remove the Phillips head screw and lift from the slots at the
bottom. To properly connect the wiring from a remote wall
thermostat, follow these steps:
1. Order the 8-pin connector from GE Appliances Service.
Call 1-800-626-2002 and order WP26X24981. A
connector is required for each unit being controlled by
a wall thermostat
2. Install the remote thermostat according to the
directions included with it.
8VLQJZLUHQXWVLQFOXGHGZLWKWKHSLQFRQQHFWRU
connect the wiring from the wall thermostat per the
following; (Proper connection of the wiring is critical.
Improper hookups could result in damage to the air
conditioner components and may not be covered by
the product warranty) After properly making the wire
nut connections, wrap the 7 connectors together with
electrical tape and push them into the lower right
FRUQHURIWKHFRQWUROER[RSHQLQJWRNHHSWKHPRXWRI
the way.
Connector Wire Color Codes Thermostat Connections
Black Common
White
Electric Heater
Yellow Compressor
Blue B terminal
(heatpump models only)
Green
Fan High
Tan
Fan low
Red 24 VAC
Download manual in English (PDF, 1.1 MB)
(Consider the environment and only print this manual if it is really necessary)

Loading…

Rating

Let us know what you think about the GE AJCM10ACHK1 Air Conditioner by leaving a product rating. Want to share your experiences with this product or ask a question? Please leave a comment at the bottom of the page.
Are you satisfied with the GE AJCM10ACHK1 Air Conditioner?
Yes No
Be the first to rate this product
0 votes

Join the conversation about this product

Here you can share what you think about the GE AJCM10ACHK1 Air Conditioner. If you have a question, first carefully read the manual. Requesting a manual can be done by using our contact form.

More about this manual

We understand that it’s nice to have a paper manual for your GE AJCM10ACHK1 Air Conditioner. You can always download the manual from our website and print it yourself. If you would like to have an original manual, we recommend you contact GE. They might be able to provide an original manual. Are you looking for the manual of your GE AJCM10ACHK1 Air Conditioner in a different language? Choose your preferred language on our homepage and search for the model number to see if we have it available.

Specifications

Brand GE
Model AJCM10ACHK1
Category Air Conditioners
File type PDF
File size 1.1 MB

All manuals for GE Air Conditioners
More manuals of Air Conditioners

Frequently Asked Questions about GE AJCM10ACHK1 Air Conditioner

Our support team searches for useful product information and answers to frequently asked questions. If you find an inaccuracy in our frequently asked questions, please let us know by using our contact form.

How often should I clean or replace the filters in my air conditioner? Verified

It's advisable to check the filters of your air conditioner 4 times a year. Dirty filters can be cleaned with the use of a vacuum cleaner or can be washed, depending on which type they are. During maintenance a professional should judge whether it is time to replace the filters.

This was helpful (2700) Read more

What does BTU stand for? Verified

BTU stands for British Thermal Unit. This is unit to indicate the capacity to cool.

This was helpful (966) Read more

Does every air conditioner also function as a dehumidifier? Verified

The cold air produced by an air conditioner often has a relatively low humidity. However, the effect is less than when using an actual dehumidifier. Some air conditioners do have a special feature to dehumidify the air.

This was helpful (719) Read more

What is R-410A? Verified

R-410A is a cooling agent that is used in appliances that cool up to 0°C, like refrigerators and air conditioners. It is the replacement of older cooling agents and does not damage the ozon layer.

This was helpful (497) Read more

Can I place my mobile air conditioner in a cabinet to get it out of sight? Verified

No, absolutely not. A mobile air conditioner needs space to allow airflow and air intake. In a small space the device can overheat.

This was helpful (356) Read more

What is the best place to mount the indoor unit of a split-type air conditioner? Verified

This depends on the space, but in general the following rules can be followed. Make sure that there is nothing obstructing the airflow. Make sure the location is accessible for maintenance. Mount the unit at least 2 meters from the ground.

This was helpful (356) Read more

Does an air conditioner have a negative influence on air quality? Verified

If the air conditioner has been properly maintained then it will have no influence on air quality. If for example a filter hasn't been replaced for a long time, or other maintenance has not been performed, than an air conditioner can produce dirty air.

This was helpful (356) Read more

Can my GE appliance also run on a generator? Verified

In general this is possible, but always check this with the manufacturer of your generator. Also be aware that some appliances require a lot of power when starting up (ie: refrigerators, freezers and air conditioners). It's also a good idea to use a generator that is voltage regulated and surge protected. When in doubt you should contact the manufacturer.

This was helpful (39) Read more