Press and hold the
test / button for
5 seconds.
1. POSITIONING
1
Switch off electricity supply.
Ensure a permanent connection to the house wiring is made in a suitable junction box.
Using a screwdriver, gently open the 3 clips on the base
to remove the base plate.
Fit the base to ceiling using the screws provided. Feed the
wiring through the hole in the base plate or via YT2
trunking knock-outs at the side.
Connect the wiring to the connector terminals.
Ensure that the house wiring ‘Earth’ is only
terminated in the terminal
marked ‘ ’ as indicated.
Unwrap battery. Insert battery into battery compartment
(match ‘+’ to ‘+’). Press and hold the test / button for
5 seconds. The alarm will sound.
2d
2c
2a
2b
2. INSTALLATION
3. MAINTENANCE
3a
Test the alarm every month.
Press the test / button for
5 seconds. The alarm will sound.
3b
Vacuum your alarm
every 3 months.
5a
For multiple alarm installations use a ‘three core and earth’ style cable between all the alarms to be interconnected.
Connect the interconnect cable between each alarm’s 'I' terminal.
5b
Test each alarm and ensure every connected alarm
sounds within 10 seconds.
3c
Do not use cleaners or solvents.
3d
Do not paint the alarm.
TROUBLESHOOTING GUIDE WARRANTY AND DISPOSAL
In a known false alarm, the alarm can be silenced temporarily.
4. SILENCE FEATURE
Up to 12 FireAngel mains smoke (SW1), heat (HW1) or carbon monoxide alarms (CW1) can be
interconnected on a single network.
5. OPTIONAL INTERCONNECTING FEATURE
SW1-PF MAINS POWERED OPTICAL SMOKE ALARM
WITH 9V BATTERY BACK-UP
USER MANUAL
220-240 V AC 50-60 Hz mains powered smoke alarm. 9V battery back-up.
WARNING: Wiring should be installed by a qualified electrician in accordance with local building standards.
The wiring must conform to current regulations for electrical installations. Check with local building and fire
regulations for your property, to ensure compliance.
Optical smoke alarms are suitable for detecting slow smouldering fires. Like other smoke alarms, they can be
subject to nuisance alarms from steam and should not be placed near bathrooms.
For the earliest warning, we recommend smoke alarms are fitted in all rooms where the temperature is
between 0°C (32°F) and 40°C (104°F).
Prolonged exposure to temperatures outside those stated above will reduce product life.
This smoke alarm is not intended for any non-residential, commercial or industrial application, nor for any
other purpose than described above.
WARNING: Experience has shown that children may not be woken by fire alarm tones. It is important that
children are never left alone in a house. Families should have a fire escape plan that is rehearsed, so that
everyone knows how to escape when fire occurs. The immediate priority when fire occurs is to ensure that
any sleeping children are woken from sleep and are immediately taken to a place of safety outside the
property, along with all other occupants. The fire and rescue service should always be called without delay,
no matter how small the fire.
GN5042R9
Turn the electricity supply back on and check
that the green LED is on.
2f
Replace the alarm every
10 years.
3e
Do not use any other test method except
the process described in this manual.
IMPORTANT: The circuit used to Power the alarm must be a 24 hour voltage circuit that cannot be turned off by a switch.
In accordance with BS 5839: Part 6, we recommend: For mains powered alarms, each with an integral standby supply, the mains
electricity supply should take the form of either a) an independent circuit at the dwelling’s main circuit board, in which case no
other electrical equipment should be connected to this circuit (other than a dedicated monitoring device installed to indicate
failure of the mains electricity supply to the alarms); or b) a separately electrically protected, regularly used local lighting circuit.
Check with local building and fire regulations for your property, to ensure compliance.
Ensure dust cover is removed before operation.
The red LED on the front of the alarm should flash once every 32 seconds (approx.) to show that the alarm sensor is actively
monitoring for smoke. When the test button is pressed, the alarm will flash once every 8 seconds for 8 minutes.
If desired, the alarm can be interconnected with up to 11 other smoke (SW1), heat (HW1) or carbon monoxide (CW1) alarms from
the FireAngel range via the 'I' connector. (See Optional Interconnecting Feature).
Smoke alarms can react to cooking fumes or other non emergency situations. Your alarm features ‘Silence’ technology.
In the event of a known false alarm you can temporarily silence it by pressing the test / button. After 8 minutes your alarm will
automatically return to full sensitivity.
The red LED on the front of the alarm will flash once every 8 seconds to show that it is in Silence mode.
The alarm will sound continuously and the red LED will flash every second when the alarm senses smoke.
NEVER IGNORE ANY ALARM. If an alarm is sounding, it is warning you of a potentially hazardous situation. Do not ignore it.
Ignoring the alarm may result in injury or death. If your smoke alarm activates and you are not absolutely certain of the source of
smoke, get everyone out of the house immediately.
The alarm will silence for
8 minutes.
4b
8
FireAngel Safety Technology Limited warrants to the original purchaser that its enclosed smoke alarm be free from defects in materials and
workmanship under normal residential use and service for a period of 5 (five) years from the date of purchase (not including the replaceable
battery). Provided product is sent back to FireAngel Safety Technology Limited with proof and date of purchase, FireAngel Safety Technology
Limited hereby warrants that during the 5 (five) year period commencing from the date of purchase FireAngel Safety Technology Limited, at its
discretion, agrees to replace the unit free of charge. The warranty on any replacement SW1 alarm, will last for the remainder of the period of the
original warranty in respect of the alarm originally purchased – that is from the date of original purchase and not from the date of receipt of the
replacement product. FireAngel Safety Technology Limited reserves the right to offer an alternative product similar to that being replaced if the
original model is no longer available or in stock. This warranty applies to the original retail purchaser from the date of original retail purchase and
is not transferable. Proof of purchase is required.
This warranty does not cover damage resulting from accident, misuse, disassembly, abuse or lack of reasonable care of the product, or
applications not in accordance with the user manual. It does not cover events and conditions outside of FireAngel Safety Technology Limited’s
control, such as Acts of God (fire, severe weather etc.). It does not apply to retail stores, service centres or any distributors or agents. FireAngel
Safety Technology Limited will not recognise any changes to this warranty by third parties.
FireAngel Safety Technology Limited shall not be liable for any incidental or consequential damages caused by the breach of any expressed or
implied warranty. Except to the extent prohibited by applicable law, any implied warranty of merchantability or fitness for a particular purpose is
limited in duration for 5 (five) years.
This warranty does not affect your statutory rights. Except for death or personal injury, FireAngel Safety Technology Limited shall not be liable
for any loss of use, damage, cost or expense relating to this product or for any indirect, or consequential loss, damages or costs incurred by
you or any other user of this product.
DISPOSAL
Waste electrical products should not be disposed of with your other household waste. The alarm is ideally suited for disposal within the
waste electronic and electrical equipment (WEEE) recycling scheme.
Please recycle where facilities exist. Check with your local authority, retailer or contact our Technical Support team for recycling/disposal
advice as regional variations apply.
Once the batteries are removed, the low battery warning chirp will stop. The batteries should always be removed before disposal.
Do not attempt to open. Do not burn.
6. LOW BATTERY WARNING
Your alarm requires 1 x 9V (PP3) battery. Under normal use, the battery should last approximately one year.
Use of a battery other than those recommended here may have a detrimental effect on the alarm performance:
Duracell MN1604, Gold Peak: GP1604S, GP1604A, Raymax: 6F22, 6LR61.
6a
When the alarm battery is low, the alarm will ‘chirp’
and the LED will flash once every 32 seconds.
6c
Using a screwdriver,
gently open the 3
clips on the base to
remove the alarm.
10
6d
Replace the batteries and re-install.
(See 'Installation')
6e
Always test the alarm after replacing
the batteries.
IMPORTANT: Align arrows on the side of the alarm and
the side of the base. Gently push alarm onto base.
2e
On an interconnected network, only the alarm that senses the fire will sound and flash its LED. Other connected alarms will sound a
warning but will not flash their LED. Do not connect more than 11 other devices.
IMPORTANT: The interconnect wire (minimum 0.75 mm2 cable) must be treated as Live, it should be insulated and sheathed.
Mains 230V AC
Power Supply
WIRING KEY
= Live
= Interconnect
= Neutral
= Earth
To other alarms
if fitted
ALARM TEST:
Press and hold the test / button for
5 seconds. The alarm will sound.
2g
Switch off electricity supply.
6b
If the green LED does not
light when the alarm is
connected to power
Check that your smoke alarm is connected to the power supply and that the battery is correctly
installed.
If your smoke alarm does
not sound during testing
Check that your alarm is connected to the power supply and that the battery is installed correctly.
If testing after installation, allow a few seconds for the alarm to settle.
Push and hold the centre of the test / button firmly for 5 seconds.
Check that the alarm is properly connected to the mains power.
If your smoke alarm
activates when no smoke
is visible
Check the location of your smoke alarm.
Clean the smoke alarm
If your smoke alarm
sounds unusual or ‘chirps’
intermittently
Check the location of your smoke alarm.
Check that your smoke alarm is definitely the source of the chirping; make sure the noise isn’t
coming from another alarm.
If the alarm ‘chirps’ every 32 seconds and the red LED flashes at the same time - replace the
battery.
If the alarm ‘chirps’ every 32 seconds without a red LED flash, a fault is indicated - contact
Techincal Support.
If you experience frequent
unwanted alarms
Check the location of your smoke alarm.
Clean the smoke alarm.
Your smoke alarm is suitable for the landing,
hallway, bedroom, living room and dining
room.
Smoke alarms should be sited at least
300mm from light fittings and walls. Ideally
as central as possible in the room.
If there is fluorescent lighting, smoke alarms
should be installed at least 1500mm from
these fittings and wiring. Keep any wiring at
least 1000mm from fluorescent lighting. Do
not use circuits containing fluorescent light
fittings or dimmer switches.
Smoke alarms should be positioned at no
more than 600mm vertically below the
highest point in the room.
If positioning your smoke alarm on the wall,
the top of the alarm must be between
150mm and 300mm below the ceiling, and
at least 300mm from a neighbouring wall.
Locations of alarms must be compliant
with either BS 5839: Part 6 or relevant
Building Regulations if in any doubt.
300mm
300mm
150mm
150mm
600mm
FireAngel Safety Technology Limited. Email: (UK) technicalsupport@fireangeltech.com, (DE) technik@fireangeltech.com,
(FR) supporttechnique@fireangeltech.com, (NL) klantenservice@fireangeltech.com, (INT) Internationalsupport@fireangeltech.com
Note: This user manual is also available in large text and other formats. Please email: technicalsupport@fireangeltech.com or call 0330 094 5830 for further information.
0905-CPR-00650
EN 14604:2005 +AC:2008
Smoke alarm devices
FSTDOP19005
19
© 2019 FireAngel Safety Technology Limited
Vanguard Centre, Coventry CV4 7EZ, UK
www.fireangeltech.com
Technical Support
Online: www.fireangeltech.com/support
E-mail: technicalsupport@fireangeltech.com
Phone: 0330 094 5830
Fire & Rescue Customers: 0800 141 2561
297 mm
420 mm
GN5042
Siterwell
W = 297mm H = 420mm60 GSM White Paper
R8. Phase 2 updates
R9. Child Safety Warning
1 of 1
SW1-PF-Q /
SW1-PF-T
User Manual
Dimensions & Information
Pantone Rhodamine Red C
Die Cut Lines
Pantone Medium Blue C
Fold Lines
Pantone Bright Green
Glue Areas
Pantone Bright Red C
Product Indication
Pantone Medium Yellow
Artwork Information & Signoff
IMPORTANT INFORMATION: Ensure that you are printing / manufacturing from the original artwork file and not a low-quality preview file
CONFIDENTIAL: The information provided in this document is proprietary to FireAngel Saftey Technology Ltd. and as such should only be
used/shared for the exclusive manufacture of those products specified.
Artwork Key:
Drawing No:
Drawing Information: Graphic Information:
Supplier:
Revision No:
Sheet No:
Product / Pack Code:
Material:
Size:
Notes & Instructions:
9
Tschaka R-M
03/09/2020
Drawn By:
Date:
Description / Title:
Black
Print Colours:
Content Quality Product Info Cert Marks
TRM
CCB
DB
GA
IB
Design & Brand Barcode & UIC Messaging
WP
ACL
KH
JD
HG
ML
Marketing
Customer Service
JW
ZH
CD
AE
TB
Approval:
Download manual in English (PDF, 1.01 MB)
(Consider the environment and only print this manual if it is really necessary)

Loading…

Rating

Let us know what you think about the FireAngel SW1-PF Smoke Detector by leaving a product rating. Want to share your experiences with this product or ask a question? Please leave a comment at the bottom of the page.
Are you satisfied with the FireAngel SW1-PF Smoke Detector?
Yes No
Be the first to rate this product
0 votes

Join the conversation about this product

Here you can share what you think about the FireAngel SW1-PF Smoke Detector. If you have a question, first carefully read the manual. Requesting a manual can be done by using our contact form.

More about this manual

We understand that it’s nice to have a paper manual for your FireAngel SW1-PF Smoke Detector. You can always download the manual from our website and print it yourself. If you would like to have an original manual, we recommend you contact FireAngel. They might be able to provide an original manual. Are you looking for the manual of your FireAngel SW1-PF Smoke Detector in a different language? Choose your preferred language on our homepage and search for the model number to see if we have it available.

Specifications

Brand FireAngel
Model SW1-PF
Category Smoke Detectors
File type PDF
File size 1.01 MB

All manuals for FireAngel Smoke Detectors
More manuals of Smoke Detectors

Frequently Asked Questions about FireAngel SW1-PF Smoke Detector

Our support team searches for useful product information and answers to frequently asked questions. If you find an inaccuracy in our frequently asked questions, please let us know by using our contact form.

Where should I place my smoke detector? Verified

This depends on the situation, but in a home it is best to place at least one smoke detector on every floor. Try to place them in hallways or other spaces that connect different rooms and never place the smoke detector directly next to a kitchen or bathroom. Also keep at least 30 centimeters of space between a smoke detector and a lamp.

This was helpful (300) Read more

Can I use candles if I have a smoke detector? Verified

This partially depends on the sensitivity of the smoke detector. In many cases a candle can be used as long as it is not placed in direct proximity of the smoke detector. When blowing out the candles, smoke can be generated that might trigger the smoke detector.

This was helpful (59) Read more

Is a smoke detector the same as a carbon monoxide detector? Verified

No! A smoke detector will not function as a carbon monoxide detector and vice versa.

This was helpful (37) Read more