User’s Guide
Analog Multimeter
Model 38070
Introduction
Congratulations on your purchase of the Extech model 38070 Analog
Multimeter. This device measures AC/DC Voltage, DC Current, Resistance,
and dB, displaying measurements in analog format. Properly used, this meter
will provide many years of reliable service.
WARNING: USE EXTREME CAUTION IN THE USE OF THIS DEVICE.
Improper use of this device can result in injury or death. Follow all safeguards
suggested in this manual in addition to the normal safety precautions used in
working with electrical circuits. DO NOT service this device if you are not
qualified to do so.
Safety Instructions
This meter has been designed for safe use, but must be operated with caution.
The rules listed below must be carefully followed for safe operation.
1. NEVER apply voltage or current to the meter that exceeds the specified
maximum:
Input Protection Limits
Function Maximum Input
V DC or V AC 500V AC and DC
mA DC 500mA DC
Resistance 50V DC/AC
2. USE EXTREME CAUTION when working with high voltages.
3. DO NOT measure voltage if the voltage on the "COM" input jack exceeds
500V above earth ground.
4. NEVER connect the meter leads across a voltage source while the
function switch is in the current or resistance mode. Doing so can
damage the meter.
5. ALWAYS discharge filter capacitors in power supplies and disconnect the
power when making resistance tests.
6. ALWAYS turn off power and disconnect test leads before opening the
covers to replace the fuse or battery.
7. NEVER operate the meter unless the back cover and the battery and fuse
covers are in place and fastened securely.
8. If the equipment is used in a manner not specified by the manufacturer,
the protection provided by the equipment may be impaired.
Safety Symbols
This symbol adjacent to another symbol, terminal or operating
device indicates that the operator must refer to an explanation
in the Operating Instructions to avoid personal injury or damage
to the meter.
This WARNING symbol indicates a potentially hazardous
situation, which if not avoided, could result in death or serious
injury.
This CAUTION symbol indicates a potentially hazardous
situation, which if not avoided, may result damage to the
product.
This symbol advises the user that the terminal(s) so marked
must not be connected to a circuit point at which the voltage
with respect to earth ground exceeds 500V.
This symbol adjacent to one or more terminals identifies them
as being associated with ranges that may, in normal use, be
subjected to particularly hazardous voltages. For maximum
safety, the meter and its test leads should not be handled when
these terminals are energized.
This symbol indicates that a device is protected throughout by
double insulation or reinforced insulation.
Controls and Jacks
1. Scale
2. Pointer
3. Scale zero adjust
4. Ohms zero adjust
5. Rotary function switch
6. Positive V, mA and input jack
7. COM input jack
Specifications
Function Range Accuracy
DC Voltage 500V
± 4% of full scale
250V
50V
10V
AC Voltage
(50/60Hz)
500V
± 5% of full scale
250V
50V
10V
DC Current
250mA
± 4% of full scale
50Ma
0.5mA
Resistance
Rx10 (10,000
± 5% of full scale
Rx1k (1,000,000
Decibels -10 to +56 dB (4 ranges)
0dB=1mW in 600
Max input voltage 500V AC/DC
Input Sensitivity, 2kV
Frequency Range 50/60Hz
Battery 0ne (1) 1.5V AA battery
Fuse 500mA/250 fast blow (5mmx20mm)
Operating Temperature 41
o
F to 104
o
F (5
o
C to 40
o
C)
Storage Temperature 14
o
F to 122
o
F (-10
o
C to 50
o
C)
Operating Humidity Max 80% up to 87ºF (31ºC) decreasing linearly to
50% at 104ºF (40ºC)
Storage Humidity <80%
Operating Altitude 7000ft. (2000meters) maximum.
Weight 3.88oz (110g)
Size 3.82x3.34x1.3” (97x65x33mm)
Safety For indoor use and in accordance with the
requirements for double insulation to IEC1010-1
(1995): EN61010-1 (1995) Overvoltage Category II
500V, Pollution Degree 2. UL, CE Approved
1
2
3
4
5
6
7
WARNING
CAUTION
MAX
500V
SupportLines:U.S.(877)4398324;International:+1(603)3247800
TechnicalSupport:Option3;Email:support@extech.com
Repair&Returns:Option4;Email:repair@extech.com
Productspecificationsaresubjecttochangewithoutnotice
Pleasevisitourwebsiteforthemostuptodateinformation
www.extech.com
FLIRCommercialSystems,Inc.,9
TownsendWest,Nashua,NH03063
USA
ISO9001Certified
Download manual in English (PDF, 0.46 MB)
(Consider the environment and only print this manual if it is really necessary)

Loading…

Rating

Let us know what you think about the Extech 38070 Multimeter by leaving a product rating. Want to share your experiences with this product or ask a question? Please leave a comment at the bottom of the page.
Are you satisfied with the Extech 38070 Multimeter?
Yes No
Be the first to rate this product
0 votes

Join the conversation about this product

Here you can share what you think about the Extech 38070 Multimeter. If you have a question, first carefully read the manual. Requesting a manual can be done by using our contact form.

More about this manual

We understand that it’s nice to have a paper manual for your Extech 38070 Multimeter. You can always download the manual from our website and print it yourself. If you would like to have an original manual, we recommend you contact Extech. They might be able to provide an original manual. Are you looking for the manual of your Extech 38070 Multimeter in a different language? Choose your preferred language on our homepage and search for the model number to see if we have it available.

Specifications

Brand Extech
Model 38070
Category Multimeters
File type PDF
File size 0.46 MB

All manuals for Extech Multimeters
More manuals of Multimeters

Manual Extech 38070 Multimeter

Related products

Related categories