Manual Danby DAC140EBIBDB Air Conditioner

Need a manual for your Danby DAC140EBIBDB Air Conditioner? Below you can view and download the PDF manual for free in English. This product currently has 7 frequently asked questions, 0 comments and has 0 votes. If this is not the manual you want, please contact us.

Is your product defective and the manual offers no solution? Go to a Repair Café for free repair services.

Manual

Loading…

SAVE THESE INSTRUCTIONS!
Note about fluorinated gasses
Fluorinated greenhouse gases are contained in hermetically sealed equipment. For specific information
on the type, the amount and the C02 equivalent in tonnes of the fluorinated greenhouse gas on some
models. Please refer to the relevant label on the unit itself.
Installation, service, maintenance and repair of this unit must be performed by a certified technician.
Product installation and recycling must be performed by a certified technician.
WARNING for using R32 refrigerant
Do not use means to accelerate the defrosting process or to clean other than those recommended by the
manufacturer.
The appliance shall be stored in a room without continuously operating ignition sources for example,
open flames, an operating gas appliance or an operating electric heater.
Do not pierce or burn.
Be aware that the refrigerants may not contain an odor.
The appliance should be installed, operated and stored in a room with a floor area according to the
amount of refrigerant to be charged. For specific information on the type of gas and the amount,
please refer to the relevant label on the unit itself. When there are differences between the label and the
manual on the minimum room area description, the description on the label shall prevail.
Compliance with national gas regulations shall be observed.
Keep ventilation openings clear of obstruction.
The appliance shall be stored so as to prevent mechanical damage from occurring.
A warning that the appliance shall be stored in a well-ventilated area where the room size corresponds
to the room area as specified for operation.
Any person involved with working on the refrigerant circuit should hold a current, valid certificate from
an industry accredited assessment authority which authorizes their competence to handle refrigerants
safely in accordance with an industry recognized assessment specification. Examples of such work are:
breaking into the refrigerating circuit; opening of sealed components; opening of ventilated enclosures.
Servicing shall only be performed as recommended by the manufacturer. Maintenance and repair
requiring the assistance of other skilled personnel shall be carried out under the supervision of the
person competent in the use of flammable refrigerants.
Please follow the instruction carefully to handle, install, clear and service the air conditioner to
avoid any damage or hazard. Flammable refrigerant R32 is used within this air conditioner. When
maintaining or disposing of the air conditioner the refrigerant must be recovered properly and should
not be allowed to discharge to the air directly.
No open fire or device like switch which may generate spark/arcing shall be around air conditioner to
avoid causing ignition of the flammable refrigerant used.
Please follow the instruction carefully to store or maintain the air conditioner to prevent mechanical
damage from occurring.
Flammable refrigerant -R32 is used in air conditioner. Please follow the instruction carefully to avoid
any hazard. For specific information on the type of gas and the amount, please to the relevant label on
the unit itself.
The appliance shall be stored in a room without continuously operating open flames (for example an
operating gas appliance) and ignition sources (for example an operating electric heater).
Transport of equipment containing flammable refrigerants: See transport regulations.
Marking of equipment using signs: See local regulations.
Disposal of equipment using flammable refrigerants: See national regulations.
Storage of equipment / appliances: The storage of equipment should be in accordance with the
manufacturer’s instructions.
Storage of packed (unsold) equipment: Storage package protection should be constructed such that the
mechanical damage to the equipment inside the package will not cause a leak of the refrigerant charge.
The maximum number of pieces of equipment permitted to be stored together will be determined by local
regulations.
Important Safety Information
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
Download manual in English (PDF, 3.4 MB)
(Consider the environment and only print this manual if it is really necessary)

Loading…

Rating

Let us know what you think about the Danby DAC140EBIBDB Air Conditioner by leaving a product rating. Want to share your experiences with this product or ask a question? Please leave a comment at the bottom of the page.
Are you satisfied with the Danby DAC140EBIBDB Air Conditioner?
Yes No
Be the first to rate this product
0 votes

Join the conversation about this product

Here you can share what you think about the Danby DAC140EBIBDB Air Conditioner. If you have a question, first carefully read the manual. Requesting a manual can be done by using our contact form.

More about this manual

We understand that it’s nice to have a paper manual for your Danby DAC140EBIBDB Air Conditioner. You can always download the manual from our website and print it yourself. If you would like to have an original manual, we recommend you contact Danby. They might be able to provide an original manual. Are you looking for the manual of your Danby DAC140EBIBDB Air Conditioner in a different language? Choose your preferred language on our homepage and search for the model number to see if we have it available.

Specifications

Brand Danby
Model DAC140EBIBDB
Category Air Conditioners
File type PDF
File size 3.4 MB

All manuals for Danby Air Conditioners
More manuals of Air Conditioners

Frequently Asked Questions about Danby DAC140EBIBDB Air Conditioner

Our support team searches for useful product information and answers to frequently asked questions. If you find an inaccuracy in our frequently asked questions, please let us know by using our contact form.

How often should I clean or replace the filters in my air conditioner? Verified

It's advisable to check the filters of your air conditioner 4 times a year. Dirty filters can be cleaned with the use of a vacuum cleaner or can be washed, depending on which type they are. During maintenance a professional should judge whether it is time to replace the filters.

This was helpful (2746) Read more

What does BTU stand for? Verified

BTU stands for British Thermal Unit. This is unit to indicate the capacity to cool.

This was helpful (986) Read more

Does every air conditioner also function as a dehumidifier? Verified

The cold air produced by an air conditioner often has a relatively low humidity. However, the effect is less than when using an actual dehumidifier. Some air conditioners do have a special feature to dehumidify the air.

This was helpful (752) Read more

What is R-410A? Verified

R-410A is a cooling agent that is used in appliances that cool up to 0°C, like refrigerators and air conditioners. It is the replacement of older cooling agents and does not damage the ozon layer.

This was helpful (517) Read more

Does an air conditioner have a negative influence on air quality? Verified

If the air conditioner has been properly maintained then it will have no influence on air quality. If for example a filter hasn't been replaced for a long time, or other maintenance has not been performed, than an air conditioner can produce dirty air.

This was helpful (372) Read more

What is the best place to mount the indoor unit of a split-type air conditioner? Verified

This depends on the space, but in general the following rules can be followed. Make sure that there is nothing obstructing the airflow. Make sure the location is accessible for maintenance. Mount the unit at least 2 meters from the ground.

This was helpful (370) Read more

Can I place my mobile air conditioner in a cabinet to get it out of sight? Verified

No, absolutely not. A mobile air conditioner needs space to allow airflow and air intake. In a small space the device can overheat.

This was helpful (369) Read more
Manual Danby DAC140EBIBDB Air Conditioner