Installing the Outdoor Unit
1. Install the drain port and drain hose (for the
heat pump model only).
The condensate drains from the outdoor unit
when the unit is in operation. In order not to
disturb your neighbourhood area and
protect the environment, install a drain port
and drain hose to direct the condensate
water.
2. Install and x the outdoor unit.
Fix it with bolts and nuts tightly on a at and strong oor. If the supporter is
mounted on a wall or roof, make sure it is securely fastened to prevent it
from swaying in the event of severe vibrations or high winds.
3. Outdoor unit piping connection.
Remove the valve caps from the 2-way and 3-way valves. Connect the pipe
to the 2-way and 3-way valves separately according to the required torque.
4. Outdoor Unit cable connection (see the previous page).
Air Purging
The air, which contains moisture from the refrigeration cycle, may cause a
malfunction in the compressor. After connecting the indoor and outdoor units,
evacuate air and moisture from the system using a vacuum pump. Follow the
given steps for air purging:
1. Unscrew and remove the caps from the 2-way and 3-way valves.
2. Unscrew and remove the cap from the service valve.
3. Connect the vacuum pump’s exible hose to the service valve.
4. Start the vacuum pump for 10-15 minutes until the vacuum reaches
10mmHg absolute level.
5. With the vacuum pump still running, close the low-pressure knob on the
vacuum pump manifold. Then stop the vacuum pump.
6. Open the 2-way valve 1/4
th
turn, then close it after 10 seconds. Check the
tightness of all joints using liquid soap or an electronic leak detector.
7. Close 2-way and 3-way valves fully. Disconnect the vacuum pump exible
hose
8. Retighten all the valve caps on their respective valves.
04
Do not modify the length of the power supply cord or use an extension cord
to power the unit.
Do not share the electrical outlet with other appliances. An improper or
insufficient power supply can cause a re or an electrical shock.
The product must be properly earthed at the time of installation to prevent
electrical shocks.
For all electrical work, follow all local and national wiring standards and
regulations and the user manual. Connect the cables tightly, and clamp
them securely to prevent external forces from damaging the terminal.
Improper electrical connections can overheat and cause res or electric
shocks. All electrical connections must be made according to the Electrical
Connection Diagram located on the panels of the Control Box unit.
All wiring must be properly arranged to ensure that the Control Board Cover
can be closed properly. Failure to do that can lead to corrosion and cause the
connection points on the terminal to heat up, catch re or cause electrical
shock.
Warning for Product Use
In abnormal situations (like a burning smell), immediately turn Off the unit
and disconnect the power.
Do not insert ngers, rods or other objects into the Air Inlet or Outlet. This
may cause injury, given the fan may be rotating at high speeds.
Do not use ammable sprays such as hair spray, lacquer or paint near the
unit. This may cause res or burns.
Do not operate the Air Conditioner near or around combustible gases.
Emitted gases may collect around the unit and cause an explosion.
Do not operate your Air Conditioner in wet areas such as bathrooms or
laundry rooms. Too much exposure to water can cause short circuits.
Do not expose your body directly to cool air for a prolonged period.
Do not allow children to play with the Air Conditioner. Children must be
supervised around the unit at all times.
If the Air Conditioner is used along with burners or other heating devices,
thoroughly ventilate the room to prevent oxygen deciency.
In certain functional environments, such as kitchens, server rooms, etc., the
use of specially designed Air Conditioning Units is highly recommended.
Download manual in English (PDF, 3.48 MB)
(Consider the environment and only print this manual if it is really necessary)

Loading…

Rating

Let us know what you think about the Croma CRLA018INF283255 Air Conditioner by leaving a product rating. Want to share your experiences with this product or ask a question? Please leave a comment at the bottom of the page.
Are you satisfied with the Croma CRLA018INF283255 Air Conditioner?
Yes No
Be the first to rate this product
0 votes

Join the conversation about this product

Here you can share what you think about the Croma CRLA018INF283255 Air Conditioner. If you have a question, first carefully read the manual. Requesting a manual can be done by using our contact form.

More about this manual

We understand that it’s nice to have a paper manual for your Croma CRLA018INF283255 Air Conditioner. You can always download the manual from our website and print it yourself. If you would like to have an original manual, we recommend you contact Croma. They might be able to provide an original manual. Are you looking for the manual of your Croma CRLA018INF283255 Air Conditioner in a different language? Choose your preferred language on our homepage and search for the model number to see if we have it available.

Specifications

Brand Croma
Model CRLA018INF283255
Category Air Conditioners
File type PDF
File size 3.48 MB

All manuals for Croma Air Conditioners
More manuals of Air Conditioners

Frequently Asked Questions about Croma CRLA018INF283255 Air Conditioner

Our support team searches for useful product information and answers to frequently asked questions. If you find an inaccuracy in our frequently asked questions, please let us know by using our contact form.

How often should I clean or replace the filters in my air conditioner? Verified

It's advisable to check the filters of your air conditioner 4 times a year. Dirty filters can be cleaned with the use of a vacuum cleaner or can be washed, depending on which type they are. During maintenance a professional should judge whether it is time to replace the filters.

This was helpful (2746) Read more

What does BTU stand for? Verified

BTU stands for British Thermal Unit. This is unit to indicate the capacity to cool.

This was helpful (987) Read more

Does every air conditioner also function as a dehumidifier? Verified

The cold air produced by an air conditioner often has a relatively low humidity. However, the effect is less than when using an actual dehumidifier. Some air conditioners do have a special feature to dehumidify the air.

This was helpful (753) Read more

What is R-410A? Verified

R-410A is a cooling agent that is used in appliances that cool up to 0°C, like refrigerators and air conditioners. It is the replacement of older cooling agents and does not damage the ozon layer.

This was helpful (518) Read more

Does an air conditioner have a negative influence on air quality? Verified

If the air conditioner has been properly maintained then it will have no influence on air quality. If for example a filter hasn't been replaced for a long time, or other maintenance has not been performed, than an air conditioner can produce dirty air.

This was helpful (372) Read more

Can I place my mobile air conditioner in a cabinet to get it out of sight? Verified

No, absolutely not. A mobile air conditioner needs space to allow airflow and air intake. In a small space the device can overheat.

This was helpful (370) Read more

What is the best place to mount the indoor unit of a split-type air conditioner? Verified

This depends on the space, but in general the following rules can be followed. Make sure that there is nothing obstructing the airflow. Make sure the location is accessible for maintenance. Mount the unit at least 2 meters from the ground.

This was helpful (370) Read more
Manual Croma CRLA018INF283255 Air Conditioner

Related products

Related categories