Manual Comfee Smart Cool 7000 Plus Air Conditioner

Need a manual for your Comfee Smart Cool 7000 Plus Air Conditioner? Below you can view and download the PDF manual for free in English. This product currently has 7 frequently asked questions, 0 comments and has 0 votes. If this is not the manual you want, please contact us.

Is your product defective and the manual offers no solution? Go to a Repair Café for free repair services.

Manual

Loading…

1.Transport of equipment containing flammable refrigerants See transport regulations
2.Marking of equipment using signs See local regulations.
3.Disposal of equipment using flammable refrigerants See national regulations.
4.Storage of equipment/appliances The storage of equipment should be in accordance with the manufacturer's
instructions.
5.Storage of packed (unsold) equipment Storage package protection should be constructed such that mechanical
damage to the equipment inside the package will not cause a leak of the refrigerant charge. The maximum number
of pieces of equipment permitted to be stored together will be determined by local regulations.
6.Information on servicing
1)Checks to the area
Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that
the risk of ignition is minimised. For repair to the refrigerating system, the following precautions shall be complied
with prior to conducting work on the system.
2)Work procedure
Work shall be undertaken under a controlled procedure so as to minimise the risk of a flammable gas or vapour
being present while the work is being performed.
3)General work area
All maintenance sta and others working in the local area shall be instructed on the nature of work being carried
out. Work in confined spaces shall be avoided. The area around the workspace shall be sectioned o. Ensure that
the conditions within the area have been made safe by control of flammable material.
4)Checking for presence of refrigerant
The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure the
technician is aware of potentially flammable atmospheres. Ensure that the leak detection equipment being used is
suitable for use with flammable refrigerants, i.e. non-sparking, adequately sealed or intrinsically safe.
5)Presence of fire extinguisher
If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate fire
extinguishing equipment shall be available to hand. Have a dry powder or CO2 fire extinguisher adjacent to the
charging area.
6)No ignition sources
No person carrying out work in relation to a refrigeration system which involves exposing any pipe work that
contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead
to the risk of fire or explosion. All possible ignition sources, including cigarette smoking, should be kept suciently
far away from the site of installation, repairing, removing and disposal, during which flammable refrigerant can
possibly be released to the surrounding space. Prior to work taking place, the area around the equipment is to be
surveyed to make sure that there are no flammable hazards or ignition risks. No Smoking signs shall be displayed.
7)Ventilated area
Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting
any hot work. A degree of ventilation shall continue during the period that the work is carried out. The ventilation
should safely disperse any released refrigerant and preferably expel it externally into the atmosphere.
06
EN
Download manual in English (PDF, 36.98 MB)
(Consider the environment and only print this manual if it is really necessary)

Loading…

Rating

Let us know what you think about the Comfee Smart Cool 7000 Plus Air Conditioner by leaving a product rating. Want to share your experiences with this product or ask a question? Please leave a comment at the bottom of the page.
Are you satisfied with the Comfee Smart Cool 7000 Plus Air Conditioner?
Yes No
Be the first to rate this product
0 votes

Join the conversation about this product

Here you can share what you think about the Comfee Smart Cool 7000 Plus Air Conditioner. If you have a question, first carefully read the manual. Requesting a manual can be done by using our contact form.

More about this manual

We understand that it’s nice to have a paper manual for your Comfee Smart Cool 7000 Plus Air Conditioner. You can always download the manual from our website and print it yourself. If you would like to have an original manual, we recommend you contact Comfee. They might be able to provide an original manual. Are you looking for the manual of your Comfee Smart Cool 7000 Plus Air Conditioner in a different language? Choose your preferred language on our homepage and search for the model number to see if we have it available.

Specifications

Brand Comfee
Model Smart Cool 7000 Plus
Category Air Conditioners
File type PDF
File size 36.98 MB

All manuals for Comfee Air Conditioners
More manuals of Air Conditioners

Frequently Asked Questions about Comfee Smart Cool 7000 Plus Air Conditioner

Our support team searches for useful product information and answers to frequently asked questions. If you find an inaccuracy in our frequently asked questions, please let us know by using our contact form.

How often should I clean or replace the filters in my air conditioner? Verified

It's advisable to check the filters of your air conditioner 4 times a year. Dirty filters can be cleaned with the use of a vacuum cleaner or can be washed, depending on which type they are. During maintenance a professional should judge whether it is time to replace the filters.

This was helpful (2746) Read more

What does BTU stand for? Verified

BTU stands for British Thermal Unit. This is unit to indicate the capacity to cool.

This was helpful (986) Read more

Does every air conditioner also function as a dehumidifier? Verified

The cold air produced by an air conditioner often has a relatively low humidity. However, the effect is less than when using an actual dehumidifier. Some air conditioners do have a special feature to dehumidify the air.

This was helpful (752) Read more

What is R-410A? Verified

R-410A is a cooling agent that is used in appliances that cool up to 0°C, like refrigerators and air conditioners. It is the replacement of older cooling agents and does not damage the ozon layer.

This was helpful (517) Read more

Does an air conditioner have a negative influence on air quality? Verified

If the air conditioner has been properly maintained then it will have no influence on air quality. If for example a filter hasn't been replaced for a long time, or other maintenance has not been performed, than an air conditioner can produce dirty air.

This was helpful (372) Read more

What is the best place to mount the indoor unit of a split-type air conditioner? Verified

This depends on the space, but in general the following rules can be followed. Make sure that there is nothing obstructing the airflow. Make sure the location is accessible for maintenance. Mount the unit at least 2 meters from the ground.

This was helpful (370) Read more

Can I place my mobile air conditioner in a cabinet to get it out of sight? Verified

No, absolutely not. A mobile air conditioner needs space to allow airflow and air intake. In a small space the device can overheat.

This was helpful (369) Read more