Compliance with national gas regulations shall be observed.
Keep ventilation openings clear of obstruction.
The appliance shall be stored so as to prevent mechanical damage from occurring.
A warning that the appliance shall be stored in a well-ventilated area where the room size corre-
sponds to the room area as specified for operation.
Any person who is involved with working on or breaking into a refrigerant circuit should hold a
current valid certificate from an industry-accredited assessment authority, which authorises their
competence to handle refrigerants safely in accordance with an industry recognised assessment
specification.
Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance
and repair requiring the assistance of other skilled personnel shall be carried out under the super-
vision of the person competent in the use of flammable refrigerants.
AVERTISSEMENT
Ne pas utiliser de produits permettant d’accélérer le dégel ou de produits de nettoyage autres que
ceux recommandés par le fabricant.
L’appareil doit être entreposé dans un endroit sans source d’allumage fonctionnant en continu (par
exemple : flamme nue, appareil au gaz en marche ou radiateur électrique en marche).
Ne pas percer ni bruler.
Attention : les frigorigènes peuvent être inodores.
Please follow the instruction carefully to handle, install, clear, service the air conditioner to avoid
any damage or hazard. Flammable Refrigerant R32 is used within air conditioner. When maintai-
ning or disposing the air conditioner, the refrigerant (R32 or R290) shall be recovered properly,
shall not discharge to air directly.
No any open fire or device like switch which may generate spark/arcing shall be around air condi-
tioner to avoid causing ignition of the flammable refrigerant used.
Please follow the instruction carefully to store or maintain the air conditioner to prevent
mechanical damage from occurring.
Flammable refrigerant -R32 is used in air conditioner. Please follow the instruction carefully to avoid
any hazard.For speci-c information on the type of gas and the amount,please to the relevant label
on the unit itself.
The appliance shall be stored in a room without continuously operating open flames (for example an
operating gas appliance) and potential ignition sources (for example an operating electric heater).
For R290(Not applicable for North America)
amount of refrigerant (kg)
4
5
6
7
8
9
10
Min. room area(m²)
0.0836 and 0.1045
<
0.1045 and 0.1254
<
0.1254 and 0.1463
<
0.1463 and 0.1672
<
0.1672 and 0.1881
<
0.1881 and 0.2090
<
amount of refrigerant (kg)
11
12
13
14
Min. room area(m²)
0.2090 and 0.2299
<
0.2299 and 0.2508
<
0.2508 and 0.2717
<
0.2717 and 0.2926
<
15 0.2926 and 0.3040
<
0.0836
For R32 frigerant models:
Appliance shall be installed, operated and stored in a room with a floor area larger than 4 m .
Appliance shall not be installed in an unvertilated space, if that space is smaller than 4 m .
2
2
EN
Download manual in English (PDF, 31.33 MB)
(Consider the environment and only print this manual if it is really necessary)

Loading…

Rating

Let us know what you think about the Comfee Smart Cool 7000-1 Air Conditioner by leaving a product rating. Want to share your experiences with this product or ask a question? Please leave a comment at the bottom of the page.
Are you satisfied with the Comfee Smart Cool 7000-1 Air Conditioner?
Yes No
Be the first to rate this product
0 votes

Join the conversation about this product

Here you can share what you think about the Comfee Smart Cool 7000-1 Air Conditioner. If you have a question, first carefully read the manual. Requesting a manual can be done by using our contact form.

More about this manual

We understand that it’s nice to have a paper manual for your Comfee Smart Cool 7000-1 Air Conditioner. You can always download the manual from our website and print it yourself. If you would like to have an original manual, we recommend you contact Comfee. They might be able to provide an original manual. Are you looking for the manual of your Comfee Smart Cool 7000-1 Air Conditioner in a different language? Choose your preferred language on our homepage and search for the model number to see if we have it available.

Specifications

Brand Comfee
Model Smart Cool 7000-1
Category Air Conditioners
File type PDF
File size 31.33 MB

All manuals for Comfee Air Conditioners
More manuals of Air Conditioners

Frequently Asked Questions about Comfee Smart Cool 7000-1 Air Conditioner

Our support team searches for useful product information and answers to frequently asked questions. If you find an inaccuracy in our frequently asked questions, please let us know by using our contact form.

How often should I clean or replace the filters in my air conditioner? Verified

It's advisable to check the filters of your air conditioner 4 times a year. Dirty filters can be cleaned with the use of a vacuum cleaner or can be washed, depending on which type they are. During maintenance a professional should judge whether it is time to replace the filters.

This was helpful (2757) Read more

What does BTU stand for? Verified

BTU stands for British Thermal Unit. This is unit to indicate the capacity to cool.

This was helpful (990) Read more

Does every air conditioner also function as a dehumidifier? Verified

The cold air produced by an air conditioner often has a relatively low humidity. However, the effect is less than when using an actual dehumidifier. Some air conditioners do have a special feature to dehumidify the air.

This was helpful (761) Read more

What is R-410A? Verified

R-410A is a cooling agent that is used in appliances that cool up to 0°C, like refrigerators and air conditioners. It is the replacement of older cooling agents and does not damage the ozon layer.

This was helpful (520) Read more

Does an air conditioner have a negative influence on air quality? Verified

If the air conditioner has been properly maintained then it will have no influence on air quality. If for example a filter hasn't been replaced for a long time, or other maintenance has not been performed, than an air conditioner can produce dirty air.

This was helpful (374) Read more

Can I place my mobile air conditioner in a cabinet to get it out of sight? Verified

No, absolutely not. A mobile air conditioner needs space to allow airflow and air intake. In a small space the device can overheat.

This was helpful (371) Read more

What is the best place to mount the indoor unit of a split-type air conditioner? Verified

This depends on the space, but in general the following rules can be followed. Make sure that there is nothing obstructing the airflow. Make sure the location is accessible for maintenance. Mount the unit at least 2 meters from the ground.

This was helpful (371) Read more
Manual Comfee Smart Cool 7000-1 Air Conditioner

Related products

Related categories