Need a manual for your Casio Edifice EQW-M1100DB-1AER Watch? Below you can view and download the PDF manual for free in English. This product currently has 7 frequently asked questions, 0 comments and has 2 votes with an average product rating of 100/100. If this is not the manual you want, please contact us.

Is your product defective and the manual offers no solution? Go to a Repair Café for free repair services.

Manual

Loading…

Operation Guide 5423
E-19
Japanese Signals Chinese Signal
Fukushima
500 kilometers
Fukuoka/Saga
1,000 kilometers
1,500 kilometers
Changchun500 kilometers
Beijing
Shangqiu
Shanghai
Chengdu
Hong Kong
E-18
Approximate Reception Ranges
UK and German Signals North American Signal
Anthorn
500 kilometers
1,500 kilometers
Mainfl ingen
The Anthorn signal is receivable
within this area.
2,000 miles
(3,000 kilometers)
600 miles
(1,000 kilometers)
Fort Collins
E-17
If your Home City Code setting is this:
The watch can receive the signal from
the transmitter located here:
LONDON (LON), PARIS (PAR), ATHENS (ATH) Anthorn (England), Mainfl ingen (Germany)
HONG KONG (HKG) Shangqiu City (China)
TOKYO (TYO) Fukushima (Japan), Fukuoka/Saga (Japan)
HONOLULU (HNL), ANCHORAGE (ANC),
LOS ANGELES (LAX), DENVER (DEN),
CHICAGO (CHI), NEW YORK (NYC)
Fort Collins, Colorado (United States)
Important!
x The areas covered by HONOLULU (HNL) and ANCHORAGE (ANC) are quite far
from the calibration signal transmitters, so certain conditions may cause reception
problems.
x When HONOLULU (HNL) or HONG KONG (HKG) is selected as the Home City,
only the time and date are adjusted according to the time calibration signal. You
need to switch manually between standard time and daylight saving time (DST) if
required. See “To toggle the Home City time between standard time and daylight
saving time” (page E-34) for information about how to do this.
E-16
Radio Controlled Atomic Timekeeping
This watch receives a time calibration signal and updates its time setting accordingly.
However, when using the watch outside of areas covered by time calibration signals,
you will have to adjust the settings manually as required. See “Confi guring Current
Time and Date Settings Manually” (page E-36) for more information.
This section explains how the watch updates its time settings when the city code
selected as the Home City is in Japan, North America, Europe, or China, and is one
that supports time calibration signal reception.
E-15
To recover from the sleep state
Move the watch to a well-lit area or press any button.
E-14
Power Saving
Power Saving enters a sleep state automatically whenever the watch is left for a
certain period in an area where it is dark. The table below shows how watch functions
are affected by Power Saving.
x There actually are two sleep state levels: “second hand sleep” and “function sleep”.
Elapsed Time in Dark Operation
60 to 70 minutes (second hand
sleep)
x
x
Second Hand only stopped at 12 o’clock, all other
functions enabled
6 or 7 days (function sleep)
x All functions, including analog timekeeping, disabled
x Internal timekeeping maintained
x The watch will not enter a sleep state between 6:00 a.m. and 9:59 p.m. If the watch
is already in a sleep state when 6:00 a.m. arrives, however, it will remain in the
sleep state.
x The watch will not enter a sleep state while it is in the Stopwatch Mode.
E-13
Charging Times
Exposure Level (Brightness)
Daily
Operation
*1
Level Change *2
Level 3 Level 2 Level 1
Outdoor sunlight (50,000 lux) 8 minutes 2 hours 24 hours
Window sunlight (10,000 lux) 30 minutes 6 hours 89 hours
Window sunlight on cloudy day
(5,000 lux)
48 minutes 9 hours 144 hours
Indoor fl uorescent lighting (500 lux) 8 hours 97 hours – – –
* 1 Approximate exposure each day to generate power for normal daily operation.
* 2 Approximate amount exposure time required to take power up one level.
x The above exposure times all are for reference only. Actual exposure times depend
on lighting conditions.
x For details about the operating time and daily operating conditions, see the “Power
Supply” section of the Specifi
cations (page E-70).
E-12
Level Hand Movement Function Status
1 Normal. All functions enabled.
2
x
x
Second Hand moving at two-second
intervals.
m
m
Day Indicator changes to 1 (home
position).
Time calibration signal reception.
3
x
x
Second Hand stopped.
z
z
Hour Hand and c
c
Minute Hand stopped
at 12 o’clock.
All functions disabled.
x When power drops to Level 3, all functions will be disabled but the watch will
continue to keep time internally for about one week. If you recharge the battery
suffi ciently during this period, the analog hands will move automatically to the
correct setting and regular timekeeping will resume. After one week, all settings
(including timekeeping) will be cleared. Recharging the battery will reset all settings
to their initial factory defaults.
E-11
Power Levels
You can get an idea of the watch’s power level by
observing the movement of the
x
Second Hand in the
Timekeeping Mode.
x If the
x
Second Hand is moving normally in one-
second intervals, power is at Level 1.
x If the
x
Second Hand is moving at two-second
intervals, power is at Level 2, which is quite low (Low
battery alert). Expose the watch to light as soon as
possible so it can charge.
Moves at two-second
intervals.
30
z c
x
m
E-10
Warning!
Leaving the watch in bright light for charging can cause it to become quite hot.
Take care when handling the watch to avoid burn injury. The watch can become
particularly hot when exposed to the following conditions for long periods.
x On the dashboard of a car parked in direct sunlight
x Too close to an incandescent lamp
x Under direct sunlight
Important!
x Keep the watch in an area normally exposed to bright light when storing it for long
periods. This helps to ensure that power does not run down.
x Storing the watch for long periods in an area where there is no light or wearing it in
such a way that it is blocked from exposure to light can cause power to run down.
Make sure that the watch is exposed to bright light whenever possible.
Download manual in English (PDF, 0.63 MB)
(Consider the environment and only print this manual if it is really necessary)

Loading…

Rating

Let us know what you think about the Casio Edifice EQW-M1100DB-1AER Watch by leaving a product rating. Want to share your experiences with this product or ask a question? Please leave a comment at the bottom of the page.
Are you satisfied with the Casio Edifice EQW-M1100DB-1AER Watch?
Yes No
100%
0%
2 votes

Join the conversation about this product

Here you can share what you think about the Casio Edifice EQW-M1100DB-1AER Watch. If you have a question, first carefully read the manual. Requesting a manual can be done by using our contact form.

More about this manual

We understand that it’s nice to have a paper manual for your Casio Edifice EQW-M1100DB-1AER Watch. You can always download the manual from our website and print it yourself. If you would like to have an original manual, we recommend you contact Casio. They might be able to provide an original manual. Are you looking for the manual of your Casio Edifice EQW-M1100DB-1AER Watch in a different language? Choose your preferred language on our homepage and search for the model number to see if we have it available.

Specifications

Brand Casio
Model Edifice EQW-M1100DB-1AER
Category Watches
File type PDF
File size 0.63 MB

All manuals for Casio Watches
More manuals of Watches

Frequently Asked Questions about Casio Edifice EQW-M1100DB-1AER Watch

Our support team searches for useful product information and answers to frequently asked questions. If you find an inaccuracy in our frequently asked questions, please let us know by using our contact form.

A battery in my device is oxidized, can I still safely use it? Verified

Ja, the device can still be safely used. Firstly, remove the oxidizd battery. Never use bare hands to do this. Then clean the battery compartment with a cotton swab dipped in vinegar or lemon juice. Let it dry and insert new batteries.

This was helpful (781) Read more

My mechanical watch runs fast, what can I do? Verified

This might be caused by exposure to a magnetic field. It can be solved by a demagnetisation process performed by a professional watchmaker.

This was helpful (753) Read more

What do AM and PM stand for? Verified

AM stands for Ante Meridiem and indicates that the time is before midday. PM stands for Post Meridiem and indicates that the time is past midday.

This was helpful (650) Read more

What is a 'Chronograph'? Verified

A 'Chronograph' is literally a 'writer of time'. The term is used to describe clocks and watches that tell the time of day as well as measure a certain period of time, like a stopwatch.

This was helpful (562) Read more

What is GMT? Verified

GMT stands for Greenwich Mean Time (sometimes called UTC, standing for Coordinated Universal Time). It is the time for the longitude 0, that passes through Greenwich near London.

This was helpful (388) Read more

What is a quartz movement? Verified

Watches and clocks with a quartz movement are driven by a battery. This sends an electric current through quartz crystals that will vibrate. These vibrations are passed on to the movement. Because the vibrations have a fixed frequency, watches and clocks with a quartz movement are extremely precise.

This was helpful (386) Read more

There is moisture on the inside of the glass of my Casio watch, what should I do? Verified

Casio states that if the moisture appeared after an extreme change in temperature and disappears relatively quickly afterwards, there is probably nothing wrong. If the moisture does not disappear, you should have your watch repaired as soon as possible.

This was helpful (55) Read more
Manual Casio Edifice EQW-M1100DB-1AER Watch