To carry out this kind of operation, for example to go from natural gas to LPG, it is necessary to change the
injectors for the main burners, adjust the reduced flows (see Table 2) and adjust the pilot injectors.
All the injectors required for the adjustments are supplied in a packet along with the appliance.
The injectors for the burners are marked in hundredths of a millimetre.
4.1 CHANGING THE INJECTOR FOR THE MAIN BURNER (Fig.2)
Remove the burners, the grilles and the undertray, after first removing the knobs. The nozzles and other adjusting
devices are now accessible.
4.1.1 MAIN BURNER (Fig.2)
Unscrew injector “C” with a suitable key. Fit the required injector; check exact distance “H” for the primary air.
4.1.2 ADJUSTMENT OF THE MINIMUM SETTINGS (Fig.3)
Remove the knob, and reach through hole “D” in the panel and adjust the flame regulating screw at the minimum
position, so as to obtain a stable and uniform flame; for the appropriate flow, see Table 2.
For operation with LPG, adjusting screw “D” must be tightened all the way.
4.2 ADJUSTMENT OF THE PRIMARY AIR (Fig.2)
The primary air is correctly adjusted if the flames are stable, in other words, if the flame does not lift off when the
burner is cold, and if it does not blow back when the burner is hot.
The recommended distance for adjusting the primary air for the burners in the gas hob is shown in Fig. 2 and
indicated in Table 2.
To adjust, unscrew screw “E” and slide bush “F” to the required position.
4.3 ADJUSTMENT OF THE PILOT BURNER (Fig.4)
The pilot burner is of the type with adjustable nozzle.
To adjust nozzle “G”, inside the body, unscrew plug “L”, taking care not to lose gasket “M”; use a short screwdriver
to screw nozzle “G” in or out.
To adjust for liquid gas (LPG), nozzle “G” must be tightened all the way.
3.3 CHECKING THE MAIN BURNER
Light the appliance and check that the flame, the ignition and the minimum setting, if there is one, are correct. If
not, check the injectors and the primary air position (see Table 2).
3.2 ADJUSTMENT OF THE PRIMARY AIR (Fig.2)
The primary air is pre-adjusted in the factory; check, however that it is adjusted to figure “H”, depending on the
type of gas, given in Table 2.
4. CONVERSION FOR OPERATION WITH OTHER TYPES OF GAS
5. ACCESS TO COMPONENTS AND DISMANTLING
(To be carried out only by a qualified installer)
The components are of high quality and reliability and have no need of maintenance, however in case of necessity
they are easily accessible.
5.1 GAS VALVE, PILOT, THERMOCOUPLE ETC.
To reach them it is only necessary to remove the grilles, the burners and the undertray.
3.1 CHECKING THE SUPPLY PRESSURE (Fig.1)
The supply pressure can be measured with a manometer with “U” tube, or one of the electronic type with minimum
gradations of 0.1 mbar.
- Undo screw “A” from pressure takeoff “B”
- Connect up the manometer
- Start up the appliance and check that the pressure is as specified. If not, ascertain the cause
- At the end of the operation, refit the appliance and check the connection.
Download manual in English (PDF, 0.25 MB)
(Consider the environment and only print this manual if it is really necessary)

Loading…

Rating

Let us know what you think about the Bartscher BIG 700 1F9 Hob by leaving a product rating. Want to share your experiences with this product or ask a question? Please leave a comment at the bottom of the page.
Are you satisfied with the Bartscher BIG 700 1F9 Hob?
Yes No
Be the first to rate this product
0 votes

Join the conversation about this product

Here you can share what you think about the Bartscher BIG 700 1F9 Hob. If you have a question, first carefully read the manual. Requesting a manual can be done by using our contact form.

More about this manual

We understand that it’s nice to have a paper manual for your Bartscher BIG 700 1F9 Hob. You can always download the manual from our website and print it yourself. If you would like to have an original manual, we recommend you contact Bartscher. They might be able to provide an original manual. Are you looking for the manual of your Bartscher BIG 700 1F9 Hob in a different language? Choose your preferred language on our homepage and search for the model number to see if we have it available.

Specifications

Brand Bartscher
Model BIG 700 1F9
Category Hobs
File type PDF
File size 0.25 MB

All manuals for Bartscher Hobs
More manuals of Hobs

Frequently Asked Questions about Bartscher BIG 700 1F9 Hob

Our support team searches for useful product information and answers to frequently asked questions. If you find an inaccuracy in our frequently asked questions, please let us know by using our contact form.

Which pans can be used on an induction hob? Verified

In general all pans that are magnetic can be used on an induction hob. Almost all new pans are suited for induction.

This was helpful (1383) Read more

My hob has a power plug that doesn't fit a regular socket, what should I do? Verified

Many electric hobs (both ceramic and induction) have a different plug. This is because these appliances require a lot of power. Have the installation of the appliance done by a professional.

This was helpful (1314) Read more

Why does the ignition on my range make a clicking sound? Verified

If the range has ben cleaned with a lot of water, the knobs might have gotten wet, triggering the ignition. Let the knobs dry. If the problem persists you should contact the manufacturer.

This was helpful (1123) Read more
Manual Bartscher BIG 700 1F9 Hob

Related products

Related categories