Manual Ariston A-DW07-HBX Air Conditioner

Need a manual for your Ariston A-DW07-HBX Air Conditioner? Below you can view and download the PDF manual for free in English. This product currently has 7 frequently asked questions, 0 comments and has 0 votes. If this is not the manual you want, please contact us.

Is your product defective and the manual offers no solution? Go to a Repair Café for free repair services.

Manual

Loading…

16
Nome set completo -MW07-HBX -MW09-HBX -MW12-HBX -MW18-HBX -DW07-HBX -DW09-HBX -DW12-HBX -DW21-HBX
Nome unità interna -MW07-HIBX -MW09-HIBX -MW12-HIBX -MW18-HIBX DW07-HIBX -DW09-HIBX -DW12-HIBX -DW21-HIBX
Nome unità esterna -MW07-HOBX -MW09-HOBX -MW12-HOBX -MW18HOBX DW07-HOBX -DW09-HOBX -DW12-HOBX -DW21-HOBX
Potenza raffreddamento frig/h 1858 2098 2958 3732 1830 x 2 2140 x 2 3044 x 2 2220/3020
Potenza raffreddamento W 2160 2440 3440 4340 2130 x 2 2490 x 2 3540 x 2 2580/3507
Potenza raffreddamento BTU/h 7366 8320 11730 14799 7260 x 2 8490 x 2 12070 x 2 8798/11960
Potenza riscald. pompa calore Kcal /h 1875 2262 3059 3926 1843 x 2 2252 x 2 3035 x 2 2310/3302
Potenza riscald. pompa calore W 2180 2630 3557 4565 2144 x 2 2619 x 2 3530 x 2 2685/3840
Potenza riscald. pompa calore BTU/h 7434 8968 12429 15567 7311 x 2 8930 x 2 12040 x 2 9155/13100
Umidità asportata l / h 0,8
1,2 1,8 2,5 0,8 x 2 1,2 x 2 1,8 x 2 1,2/1,8
Potenza elettrica raffreddamento 1) W 675 760 1075 1550 1329 1667 2529 2029
Potenza elettrica riscaldamento 1) W 680 820 1029 1630 1292 1637 2487 2039
EER W W 3,2 3,2 3,2 2,8 3,2 3 2,8 3
COP W W 3,2 3,2 3,46 2,8 3,4 3,2 2,8 3,2
Tensione - frequenza - Nr. Fasi
V - Hz -Ph
230-50 - 1 230-50 - 1 230-50 - 1 230-50 - 1 230-50 - 1 230-50 - 1 230-50 - 1 230-50-1
Corrente nominale raffreddamento 1) A 2,93 3,30 4,67 6,74 5,78 7,25 11,00 8,82
Corrente nominale riscaldamento 1) A 2,96 3,57 4,47 7,09 5,62 7,12 10,81 8,87
Rumorosità massima unità interna 2) dBA 39 39 44,5 44 39 39 44,5 39/44
Rumorosità massima unità esterna 2) dBA 54 54 55 57 55 57 58 58
Portata aria u. interna (max velocità) m
3
/ h 460 460 620 620 460 460 620 460/620
Peso unità interna Kg 8 8 11 11 8 8 11 8/11
Peso unità esterna Kg 38 38 40 40 60 60 71 69
DATI TECNICI
E' importante considerare che le caratteristiche e i dati tecnici dichiarati dal costruttore fanno riferimento alla
macchina alimentata alla tensione nominale di rete specificata: 230V 50Hz.
Le prestazioni e le caratteristiche di qualsiasi macchina frigorifera sono notevolmente influenzate dalle con-
dizioni ambientali in cui lavorano l’Unità Interna e l’Unità Esterna. Ciò significa che le grandezze misurate
(temperature, pressioni, consumi elettrici, ecc.) variano secondo la situazione climatica.
Raffreddamento Riscaldamento
Unità INTERNA
27
°C 50% UR 20°C 60% UR
Unità ESTERNA 35°C 40% UR 6°C 80% UR
Legenda: °C = gradi centigradi UR = umidità relativa
I
N.B.
I dati tecnici riportati nella tabella possono subire variazioni.
Si consiglia di fare sempre riferimento hai dati riportati nell’etichetta caratteristica posta sul climatizzatore
.
Downloaded from www.Manualslib.com manuals search engine
Download manual in English (PDF, 3.27 MB)
(Consider the environment and only print this manual if it is really necessary)

Loading…

Rating

Let us know what you think about the Ariston A-DW07-HBX Air Conditioner by leaving a product rating. Want to share your experiences with this product or ask a question? Please leave a comment at the bottom of the page.
Are you satisfied with the Ariston A-DW07-HBX Air Conditioner?
Yes No
Be the first to rate this product
0 votes

Join the conversation about this product

Here you can share what you think about the Ariston A-DW07-HBX Air Conditioner. If you have a question, first carefully read the manual. Requesting a manual can be done by using our contact form.

More about this manual

We understand that it’s nice to have a paper manual for your Ariston A-DW07-HBX Air Conditioner. You can always download the manual from our website and print it yourself. If you would like to have an original manual, we recommend you contact Ariston. They might be able to provide an original manual. Are you looking for the manual of your Ariston A-DW07-HBX Air Conditioner in a different language? Choose your preferred language on our homepage and search for the model number to see if we have it available.

Specifications

Brand Ariston
Model A-DW07-HBX
Category Air Conditioners
File type PDF
File size 3.27 MB

All manuals for Ariston Air Conditioners
More manuals of Air Conditioners

Frequently Asked Questions about Ariston A-DW07-HBX Air Conditioner

Our support team searches for useful product information and answers to frequently asked questions. If you find an inaccuracy in our frequently asked questions, please let us know by using our contact form.

How often should I clean or replace the filters in my air conditioner? Verified

It's advisable to check the filters of your air conditioner 4 times a year. Dirty filters can be cleaned with the use of a vacuum cleaner or can be washed, depending on which type they are. During maintenance a professional should judge whether it is time to replace the filters.

This was helpful (2747) Read more

What does BTU stand for? Verified

BTU stands for British Thermal Unit. This is unit to indicate the capacity to cool.

This was helpful (987) Read more

Does every air conditioner also function as a dehumidifier? Verified

The cold air produced by an air conditioner often has a relatively low humidity. However, the effect is less than when using an actual dehumidifier. Some air conditioners do have a special feature to dehumidify the air.

This was helpful (755) Read more

What is R-410A? Verified

R-410A is a cooling agent that is used in appliances that cool up to 0°C, like refrigerators and air conditioners. It is the replacement of older cooling agents and does not damage the ozon layer.

This was helpful (518) Read more

Does an air conditioner have a negative influence on air quality? Verified

If the air conditioner has been properly maintained then it will have no influence on air quality. If for example a filter hasn't been replaced for a long time, or other maintenance has not been performed, than an air conditioner can produce dirty air.

This was helpful (372) Read more

What is the best place to mount the indoor unit of a split-type air conditioner? Verified

This depends on the space, but in general the following rules can be followed. Make sure that there is nothing obstructing the airflow. Make sure the location is accessible for maintenance. Mount the unit at least 2 meters from the ground.

This was helpful (371) Read more

Can I place my mobile air conditioner in a cabinet to get it out of sight? Verified

No, absolutely not. A mobile air conditioner needs space to allow airflow and air intake. In a small space the device can overheat.

This was helpful (370) Read more