Thank you for deciding to purchase this set of high-quality body analysis scales. Please
read through this operating manual carefully before starting-up the scales for the first
time, and keep it in a safe place so that this information is available to you when you
need it.
1. How do the body analysis scales work?
With these new, revolutionary scales you will obtain information about your body
composition in terms of weight, proportion of body fat (%), proportion of body water (%),
muscle mass (%) and bone mass (in kg). Your personal data, such as sex (male or
female), age and height, must first be entered into one of the individual storage cells.
Taking a measurement is then as easy as weighing yourself on a completely normal set
of scales. You need only choose your personal storage cell, stand on the scales and
within a few seconds your current body status will be displayed for you. For measuring, a
weak current is used, which gauges the resistance. Water, which is principally stored in
the musculature, conducts very well; fat, on the other hand, does not. With reference to
the measured resistance and the stored data, the body analysis scales can calculate
your body composition very accurately.
2. How to use
A measurement should preferably be taken while you are undressed and barefoot.
Since the body is naturally subject to variations (e.g. through dehydration during sport or
after a visit to the sauna, the intake of food or fluids), it is important to take
measurements under the most consistent conditions possible, in order to obtain
comparable values.
Care should be taken to ensure that measurements are always taken at the same time of
day. In the morning, immediately after getting up, body water has still not distributed itself
throughout the body. This means that the resistance is relatively high because the
conductivity in the body is still quite poor. With increasing movement throughout the day
the water distributes itself throughout the body, the conductivity of the body increases,
the resistance and thus the proportion of fat are registered less. In order to determine the
actual change of body composition it is therefore important to measure yourself always
at the same time. The easiest way to achieve this is to take your measurements in the
morning, ¼ hour after getting up either always before or always after you go to the toilet.
Despite the minimal current strength, people with pacemakers or other implants
that transmit signals must not use these body ana lysis scales! With implants such as
a titanium plate in the knee there is no danger. Nevertheless, metals do conduct currents
extremely well, as a consequence of which the body fat value is “embellished”, thus the
actual amount of fat is higher than that displayed on the scales. Trends in body
composition can nevertheless be determined equally well. In women, periodic influences
affect the results of measurements because hormonal variations influence the water
balance of the body. If there is a lot of water in the body the fat values come out lower; if
7. Error messages
“EEEE” = Overload indicator the maximum capacity of the scales (180 kg) has
been exceeded. Remove the load from the scales immediately,
otherwise the load cell could incur damage.
Or: Faulty weighing or measuring process e.g. when the scales are
not standing stably or you are not standing still on the weighing
platform.
“Lo” = Batteries are empty please replace the batteries with the battery
type intended for your scales (4 x 1.5V AAA).
Err” = The body fat proportion is either too low (below 5% cannot be shown)
or the body fat proportion is too high (over 50% cannot be shown).
8. Technical Data
Weight-bearing capacity x division: Max. 180 kg x 100 g
Indicator resolution: Proportion of body fat: 0.1%
Indicator resolution: Proportion of body water: 0.1%
Indicator resolution: Proportion of muscle mass: 0.1 %
Indicator resolution: Bone mass: 100 g
Personal storage cells: 10
Age input: 10 – 85 years
Input height: 75 225 cm
Dimensions: approx. 305 mm x 305 mm x 22 mm
Batteries: 4 x 1.5V AAA (contained in product package)
We reserve the right to make technical modifications
9. Warranty
ADE guarantees the free correction of defects resulting from material or manufacturing
faults through repair or exchange 3 years from the purchase date. Please get your
warranty section filled out and stamped by the retailer when you make your purchase. In
case of warranty, please return the scales to your retailer along with the warranty section
indicating the reason for your complaint.
CE compliance. This device suppresses electromagnetic
interference in accordance with the applicable EC directive
2004/108/EG
Please note: Under extreme electromagnetic influences e.g. when operating a radio
device in immediate proximity to the scales, the indicator value may be affected. After the
disturbing influence has stopped, the product may once again be used as intended,
although a re-activation may be necessary.
2
7
Download manual in English (PDF, 1.06 MB)
(Consider the environment and only print this manual if it is really necessary)

Loading…

Rating

Let us know what you think about the ADE BA 1402 Bella Scale by leaving a product rating. Want to share your experiences with this product or ask a question? Please leave a comment at the bottom of the page.
Are you satisfied with the ADE BA 1402 Bella Scale?
Yes No
100%
0%
1 vote

Join the conversation about this product

Here you can share what you think about the ADE BA 1402 Bella Scale. If you have a question, first carefully read the manual. Requesting a manual can be done by using our contact form.

Joseline 05-10-2022
It is necessary to calibrate the scale or because the weights vary a lot

reply | This was helpful (1) (Translated by Google)

More about this manual

We understand that it’s nice to have a paper manual for your ADE BA 1402 Bella Scale. You can always download the manual from our website and print it yourself. If you would like to have an original manual, we recommend you contact ADE. They might be able to provide an original manual. Are you looking for the manual of your ADE BA 1402 Bella Scale in a different language? Choose your preferred language on our homepage and search for the model number to see if we have it available.

Specifications

Brand ADE
Model BA 1402 Bella
Category Scales
File type PDF
File size 1.06 MB

All manuals for ADE Scales
More manuals of Scales

Frequently Asked Questions about ADE BA 1402 Bella Scale

Our support team searches for useful product information and answers to frequently asked questions. If you find an inaccuracy in our frequently asked questions, please let us know by using our contact form.

My scale shows an unrealistically low weight when I stand on it, why is that? Verified

For the best result, the scale should be standing on a hard level surface. When the scale is standing on for example a rug this can influence the measurement.

This was helpful (2508) Read more

What is BMI? Verified

BMI stands for Body Mass Index and can be calculated by dividing your weight in kilogram by your length in meters squared. For example someone with a weight of 70 kilogram and a lenght of 1,75 meter has a BMI of 22,86. A BMI between 18,5 and 25 is considered healthy.

This was helpful (1787) Read more

A battery in my device is oxidized, can I still safely use it? Verified

Ja, the device can still be safely used. Firstly, remove the oxidizd battery. Never use bare hands to do this. Then clean the battery compartment with a cotton swab dipped in vinegar or lemon juice. Let it dry and insert new batteries.

This was helpful (763) Read more

Can I use a scale with wet feet? Verified

This depends on the scale. When using a diagnostic scale it is necessary that your feet are dry in order to properly perform the measurements.

This was helpful (458) Read more