MD-CR.W00 Gallium Thermometer
a. The mercury-free clinical thermometer is a patient temperature measurement device and is indicated for measurements under the tongue, under the armpit or in the rectum.
b. The product complies with the EN12470-1:2000+A1:2009 standard concerning clinical thermometers - Part 1: Metal liquid-in-glass expansion thermometers with maximum device:
1. Conditions of use: the measuring temperature range should be between 35°C and 42°C, and the ambient temperature (only for mercury-free thermometer) should be between 20°C
and 30°C; If the ambient temperature where the thermometer is stored is lower than 20°C, please leave the thermometer at a temperature between 20°C and 30°C for at least 1-2
hours, or between 30°C and 35°C for ten minutes, before use or following any test.
2. Keep the thermometer between -10°C and 42°C during storage and transportation.
3. Disposal of the thermometer: after use, shake the thermometer so that the metallic liquid goes down, then clean it and put it in a plastic case to avoid damaging it.
Advice for correct execution of the oscillating movements: rmly grasp the end of the thermometer with the thumb and forenger and very carefully, shake the
thermometer lightly several times until the liquid drops.
c. Mode of operation
1.The liquid in the column should drop below the lowest mark of the scale before use, then clean and disinfect the clinical thermometer with medical alcohol, or place it on a sterilized plastic tube.
2.In case of oral measurement, be careful to place the thermometer correctly under the patient’s tongue and ask him to close his mouth tightly.
3. In case of rectal measurement, it is recommended to apply a lubricant on the thermometer before inserting it into the anus.
4. In case of underarm measurement, be careful to position the thermometer correctly and ask the patient to squeeze it tightly, so that it is firmly in place.
Please read the measurement taken by the clinical thermometer about 4 minutes after performing the above procedures.
d. WARNINGS
1. Warn patients not to chew, talk or play when the clinical thermometer is placed
under the tongue only;
2.Lay the children down so that they are comfortable and it is easier to hold the end
of the clinical thermometer when using rectally, to prevent it from being inserted
too deeply or slipping from the anus.
3.Refrain from bathing, eating or smoking up to half an hour before body tempera
-
ture measurement;
4.This thermometer is not intended for special applications (for example, premature
baby thermometers, basal thermometers);
e. Disposal of the clinical thermometer
The metallic liquid is an alloy composed of gallium, indium and tin; therefore, this clinical thermometer should be handled with care. In particular, care must be taken not to drop the
instrument or to handle it in any way that could cause damage. In case of breakage of the clinical thermometer, clean the metallic liquid with a cloth moistened with soap and water.
The product can be disposed of with normal household waste.
f. Description of symbols
Rev.00_09.2023
Innoliving S.p.A.
Via Merloni 2/B - 60131 Ancona Italy
Download manual in English (PDF, 0.37 MB)
(Consider the environment and only print this manual if it is really necessary)

Loading…

Rating

Let us know what you think about the Medifit MD-CR.W00 Thermometer by leaving a product rating. Want to share your experiences with this product or ask a question? Please leave a comment at the bottom of the page.
Are you satisfied with the Medifit MD-CR.W00 Thermometer?
Yes No
Be the first to rate this product
0 votes

Join the conversation about this product

Here you can share what you think about the Medifit MD-CR.W00 Thermometer. If you have a question, first carefully read the manual. Requesting a manual can be done by using our contact form.

More about this manual

We understand that it’s nice to have a paper manual for your Medifit MD-CR.W00 Thermometer. You can always download the manual from our website and print it yourself. If you would like to have an original manual, we recommend you contact Medifit. They might be able to provide an original manual. Are you looking for the manual of your Medifit MD-CR.W00 Thermometer in a different language? Choose your preferred language on our homepage and search for the model number to see if we have it available.

Specifications

Brand Medifit
Model MD-CR.W00
Category Thermometers
File type PDF
File size 0.37 MB

All manuals for Medifit Thermometers
More manuals of Thermometers

Frequently Asked Questions about Medifit MD-CR.W00 Thermometer

Our support team searches for useful product information and answers to frequently asked questions. If you find an inaccuracy in our frequently asked questions, please let us know by using our contact form.

I just took my temperature but what is actually considered a 'healthy' body temperature? Verified

This partially depends on the body part where the temperature was taken. The following can be considered healthy: Forehead 35,8 to 37,6 °C, Ear 36 to 37,8°C, rectally 36,3 to 37,8°C and orally 36 to 37,4°C.

This was helpful (959) Read more

What parts of the body are best to measure body temperature? Verified

This depends on the thermometer. Some thermometers are designed for use on specific parts of the body. With a regular thermometer, rectal usage is the fastest and most accurate way to measure body temperature.

This was helpful (336) Read more

From what temperature does a person officially have a fever? Verified

A temperature above 38°C is officially considered a fever.

This was helpful (250) Read more